Identifying diversity of patient anatomy through automated image analysis of clinical ultrasounds.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Ultrasound Pub Date : 2024-09-01 Epub Date: 2024-06-23 DOI:10.1007/s40477-024-00908-6
Dailen C Brown, Kenny Nguyen, Scarlett R Miller, Jason Z Moore
{"title":"Identifying diversity of patient anatomy through automated image analysis of clinical ultrasounds.","authors":"Dailen C Brown, Kenny Nguyen, Scarlett R Miller, Jason Z Moore","doi":"10.1007/s40477-024-00908-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Central venous catheterization (CVC) carries inherent risks which can be mitigated through the use of appropriate ultrasound-guidance during needle insertion. This study aims to comprehensively understand patient anatomy as it is visualized during CVC by employing a semi-automated image analysis method to track the internal jugular vein and carotid artery throughout recorded ultrasound videos.</p><p><strong>Methods: </strong>The ultrasound visualization of 50 CVC procedures were recorded at Penn State Health Milton S. Hershey Medical Center. The developed algorithm was used to detect the vessel edges, calculating metrics such as area, position, and eccentricity.</p><p><strong>Results: </strong>Results show typical anatomical variations of the vein and artery, with the artery being more circular and posterior to the vein in most cases. Notably, two cases revealed atypical artery positions, emphasizing the algorithm's precision in detecting anomalies. Additionally, dynamic vessel properties were analyzed, with the vein compressing on average to 13.4% of its original size and the artery expanding by 13.2%.</p><p><strong>Conclusion: </strong>This study provides valuable insights which can be used to increase the accuracy of training simulations, thus enhancing medical education and procedural expertise. Furthermore, the novel approach of employing automated data analysis techniques to clinical recordings showcases the potential for continual assessment of patient anatomy, which could be useful in future advancements.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333779/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00908-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Central venous catheterization (CVC) carries inherent risks which can be mitigated through the use of appropriate ultrasound-guidance during needle insertion. This study aims to comprehensively understand patient anatomy as it is visualized during CVC by employing a semi-automated image analysis method to track the internal jugular vein and carotid artery throughout recorded ultrasound videos.

Methods: The ultrasound visualization of 50 CVC procedures were recorded at Penn State Health Milton S. Hershey Medical Center. The developed algorithm was used to detect the vessel edges, calculating metrics such as area, position, and eccentricity.

Results: Results show typical anatomical variations of the vein and artery, with the artery being more circular and posterior to the vein in most cases. Notably, two cases revealed atypical artery positions, emphasizing the algorithm's precision in detecting anomalies. Additionally, dynamic vessel properties were analyzed, with the vein compressing on average to 13.4% of its original size and the artery expanding by 13.2%.

Conclusion: This study provides valuable insights which can be used to increase the accuracy of training simulations, thus enhancing medical education and procedural expertise. Furthermore, the novel approach of employing automated data analysis techniques to clinical recordings showcases the potential for continual assessment of patient anatomy, which could be useful in future advancements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过对临床超声波进行自动图像分析,识别病人解剖结构的多样性。
目的:中心静脉导管插入术(CVC)存在固有风险,但可通过在穿刺针插入时使用适当的超声引导来降低风险。本研究旨在通过采用半自动图像分析方法,在录制的超声视频中追踪颈内静脉和颈动脉,从而全面了解 CVC 过程中可视化的患者解剖结构:方法:宾夕法尼亚州立健康 Milton S. Hershey 医疗中心录制了 50 例 CVC 手术的超声可视化视频。开发的算法用于检测血管边缘,计算面积、位置和偏心率等指标:结果:结果显示了典型的静脉和动脉解剖学变化,在大多数病例中,动脉更圆且位于静脉后方。值得注意的是,有两个病例显示了非典型的动脉位置,强调了算法在检测异常方面的精确性。此外,还分析了血管的动态特性,发现静脉平均压缩到原来大小的 13.4%,动脉则扩张了 13.2%:这项研究提供了宝贵的见解,可用于提高模拟训练的准确性,从而增强医学教育和手术专业知识。此外,在临床记录中采用自动数据分析技术的新方法展示了持续评估患者解剖结构的潜力,这对未来的发展很有帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
期刊最新文献
Correction: Exploring the potential of contrast agents in breast cancer echography: current state and future directions. Effects of superficial tissue and intermuscular connections on rectus femoris muscle shear modulus heterogeneity. Evaluating acoustic and thermal properties of a plaque phantom. Role of acoustic radiation force impulse elastography of placenta in the diagnosis of pre-eclampsia. Intraobserver reliability and validity of a single ultrasonic measurement of the lateral condyle-capsule distance in the temporomandibular joint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1