Safety and Risk Factors of Carotid Artery Stenting with Simple Distal Filter Protection: A Single-Center Retrospective Study.

Journal of neuroendovascular therapy Pub Date : 2024-01-01 Epub Date: 2024-04-08 DOI:10.5797/jnet.oa.2023-0096
Wataru Shimohigoshi, Taisuke Akimoto, So Ozaki, Shuto Fushimi, Ryosuke Takagi, Takafumi Kawasaki, Koichi Uramaru, Junya Tatezuki, Hiroshi Manaka, Yasunobu Nakai, Katsumi Sakata, Tetsuya Yamamoto
{"title":"Safety and Risk Factors of Carotid Artery Stenting with Simple Distal Filter Protection: A Single-Center Retrospective Study.","authors":"Wataru Shimohigoshi, Taisuke Akimoto, So Ozaki, Shuto Fushimi, Ryosuke Takagi, Takafumi Kawasaki, Koichi Uramaru, Junya Tatezuki, Hiroshi Manaka, Yasunobu Nakai, Katsumi Sakata, Tetsuya Yamamoto","doi":"10.5797/jnet.oa.2023-0096","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Carotid artery stenting embolic protection devices offer various options, among which distal filter protection is the simplest and easiest to handle. However, compared to balloon protection systems, distal filter protection has more embolic complications. Therefore, we explored the risk factors of distal filter protection, intending to achieve a safer carotid artery stenting. This retrospective study was conducted to identify prognostic factors following carotid artery stenting with only distal filter protection from July 2010 to June 2021.</p><p><strong>Methods: </strong>Information on patient background, procedures and devices, and complications was collected using medical records. The data pertaining to 187 patients were analyzed after excluding the data of patients in whom other protection devices (8 cases) were used. We used FilterWire EZ as the first choice for embolic protection device and SpiderFX when the patients had difficult-to-cross lesions.</p><p><strong>Results: </strong>The patients' mean age was 71.9 ± 6.9 years, and 72 (38.5%) were symptomatic. Symptomatic (odds ratio: 2.02, p = 0.035) and difficult-to-cross lesions (odds ratio: 3.63, p = 0.0013) were factors independently associated with symptomatic complications.</p><p><strong>Conclusion: </strong>This retrospective single-center study established independent prognostic factors for carotid artery stenting with distal filter protection. For patients with symptomatic lesions and severe stenosis or bends that are difficult to pass through, it is necessary to be careful when performing carotid artery stenting with distal filter protection.</p>","PeriodicalId":73856,"journal":{"name":"Journal of neuroendovascular therapy","volume":"18 6","pages":"155-163"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189783/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neuroendovascular therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5797/jnet.oa.2023-0096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Carotid artery stenting embolic protection devices offer various options, among which distal filter protection is the simplest and easiest to handle. However, compared to balloon protection systems, distal filter protection has more embolic complications. Therefore, we explored the risk factors of distal filter protection, intending to achieve a safer carotid artery stenting. This retrospective study was conducted to identify prognostic factors following carotid artery stenting with only distal filter protection from July 2010 to June 2021.

Methods: Information on patient background, procedures and devices, and complications was collected using medical records. The data pertaining to 187 patients were analyzed after excluding the data of patients in whom other protection devices (8 cases) were used. We used FilterWire EZ as the first choice for embolic protection device and SpiderFX when the patients had difficult-to-cross lesions.

Results: The patients' mean age was 71.9 ± 6.9 years, and 72 (38.5%) were symptomatic. Symptomatic (odds ratio: 2.02, p = 0.035) and difficult-to-cross lesions (odds ratio: 3.63, p = 0.0013) were factors independently associated with symptomatic complications.

Conclusion: This retrospective single-center study established independent prognostic factors for carotid artery stenting with distal filter protection. For patients with symptomatic lesions and severe stenosis or bends that are difficult to pass through, it is necessary to be careful when performing carotid artery stenting with distal filter protection.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带简单远端滤器保护的颈动脉支架植入术的安全性和风险因素:单中心回顾性研究
目的:颈动脉支架植入术栓塞保护装置有多种选择,其中远端滤器保护装置最简单、最容易操作。然而,与球囊保护系统相比,远端滤器保护的栓塞并发症较多。因此,我们探讨了远端滤器保护的风险因素,以期实现更安全的颈动脉支架植入术。这项回顾性研究旨在确定2010年7月至2021年6月期间仅使用远端滤器保护进行颈动脉支架术后的预后因素:方法:通过病历收集患者背景、手术和设备以及并发症的信息。在排除使用其他保护装置的患者(8 例)的数据后,对 187 例患者的相关数据进行了分析。我们将FilterWire EZ作为栓塞保护装置的首选,并在患者有难以穿越的病灶时使用SpiderFX:患者的平均年龄为 71.9 ± 6.9 岁,72 例(38.5%)有症状。无症状(几率比:2.02,P = 0.035)和难以穿越的病变(几率比:3.63,P = 0.0013)是与无症状并发症独立相关的因素:这项回顾性单中心研究确定了远端滤器保护颈动脉支架置入术的独立预后因素。对于有症状病变、严重狭窄或弯曲难以通过的患者,在进行带远端滤器保护的颈动脉支架植入术时必须小心谨慎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Case of Acute Ischemic Stroke due to Tandem Lesion Treated with Endovascular Thrombectomy by Internal Carotid Artery Direct Puncture. A Case of Cavernous Sinus Dural Arteriovenous Fistula with Persistent Left Superior Vena Cava. A Case of Flow Diverter Placement for a Recurrent Large Thrombosed Middle Cerebral Artery Aneurysm. A Single-Center Experience of Mechanical Thrombectomy for Cancer-Associated Ischemic Stroke. Efficacy and Safety of Lumbar Drainage before Endovascular Treatment for Ruptured Intracranial Aneurysms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1