Olivier Taton, Pierre Alain Gevenois, Alain Van Muylem, Benjamin Bondue, Sébastien Van Laethem, Dimitri Leduc
{"title":"Improvements of the shape and strength of the diaphragm after endoscopic lung volume reduction.","authors":"Olivier Taton, Pierre Alain Gevenois, Alain Van Muylem, Benjamin Bondue, Sébastien Van Laethem, Dimitri Leduc","doi":"10.1136/thorax-2024-221375","DOIUrl":null,"url":null,"abstract":"<p><strong>Rationale: </strong>Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape.</p><p><strong>Objectives: </strong>To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves.</p><p><strong>Methods: </strong>In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion.</p><p><strong>Measurements and main results: </strong>After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmH<sub>2</sub>O (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm<sup>2</sup> (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature.</p><p><strong>Conclusions: </strong>Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength.</p><p><strong>Trial registration number: </strong>NCT05799352.</p>","PeriodicalId":23284,"journal":{"name":"Thorax","volume":" ","pages":"711-717"},"PeriodicalIF":9.0000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thorax","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/thorax-2024-221375","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Rationale: Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape.
Objectives: To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves.
Methods: In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion.
Measurements and main results: After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmH2O (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm2 (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature.
Conclusions: Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength.
期刊介绍:
Thorax stands as one of the premier respiratory medicine journals globally, featuring clinical and experimental research articles spanning respiratory medicine, pediatrics, immunology, pharmacology, pathology, and surgery. The journal's mission is to publish noteworthy advancements in scientific understanding that are poised to influence clinical practice significantly. This encompasses articles delving into basic and translational mechanisms applicable to clinical material, covering areas such as cell and molecular biology, genetics, epidemiology, and immunology.