Diagnostic accuracy of ultrasound-derived fat fraction for the detection and quantification of hepatic steatosis in patients with liver biopsy.

IF 1.9 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Ultrasonics Pub Date : 2024-06-25 DOI:10.1007/s10396-024-01472-6
Yoshiko Nakamura, Masashi Hirooka, Yohei Koizumi, Ryo Yano, Yusuke Imai, Takao Watanabe, Osamu Yoshida, Yoshio Tokumoto, Masanori Abe, Yoichi Hiasa
{"title":"Diagnostic accuracy of ultrasound-derived fat fraction for the detection and quantification of hepatic steatosis in patients with liver biopsy.","authors":"Yoshiko Nakamura, Masashi Hirooka, Yohei Koizumi, Ryo Yano, Yusuke Imai, Takao Watanabe, Osamu Yoshida, Yoshio Tokumoto, Masanori Abe, Yoichi Hiasa","doi":"10.1007/s10396-024-01472-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This retrospective study was conducted to investigate the diagnostic accuracy of ultrasound-derived fat fraction (UDFF) for grading hepatic steatosis using liver histology as the reference standard.</p><p><strong>Methods: </strong>Seventy-three patients with liver disease were assessed using UDFF and liver biopsy. Pearson's test and the Bland-Altman plot were used to assess the correlation between UDFF and histological fat content in liver sections. The UDFF cutoff values for histologically proven steatosis grades were determined using the area under the receiver operating characteristic curve (AUROC).</p><p><strong>Results: </strong>The median age of the patients was 66 (interquartile range 54-74) years, and 33 (45%) were females. The UDFF values showed a stepwise increase with increasing steatosis grade (p < .001) and were strongly correlated with the histological fat content (r = .7736, p < .001). The Bland-Altman plot revealed a mean bias of 2.384% (95% limit of agreement, - 6.582 to 11.351%) between them. Univariate regression analysis revealed no significant predictors of divergence. The AUROCs for distinguishing steatosis grades of ≥ 1, ≥2, and 3 were 0.956 (95% confidence interval [CI], 0.910-1.00), 0.926 (95% CI, 0.860-0.993), and 0.971 (95% CI, 0.929-1.000), respectively. The UDFF cutoff value of > 6% had a sensitivity and specificity of 94.8% and 82.3%, respectively, for diagnosing steatosis grade ≥ 1. There was no association between UDFF and the fibrosis stage.</p><p><strong>Conclusion: </strong>UDFF shows strong agreement with the histological fat content and excellent diagnostic accuracy for grading steatosis. UDFF is a promising tool for detecting and quantifying hepatic steatosis in clinical practice.</p>","PeriodicalId":50130,"journal":{"name":"Journal of Medical Ultrasonics","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10396-024-01472-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This retrospective study was conducted to investigate the diagnostic accuracy of ultrasound-derived fat fraction (UDFF) for grading hepatic steatosis using liver histology as the reference standard.

Methods: Seventy-three patients with liver disease were assessed using UDFF and liver biopsy. Pearson's test and the Bland-Altman plot were used to assess the correlation between UDFF and histological fat content in liver sections. The UDFF cutoff values for histologically proven steatosis grades were determined using the area under the receiver operating characteristic curve (AUROC).

Results: The median age of the patients was 66 (interquartile range 54-74) years, and 33 (45%) were females. The UDFF values showed a stepwise increase with increasing steatosis grade (p < .001) and were strongly correlated with the histological fat content (r = .7736, p < .001). The Bland-Altman plot revealed a mean bias of 2.384% (95% limit of agreement, - 6.582 to 11.351%) between them. Univariate regression analysis revealed no significant predictors of divergence. The AUROCs for distinguishing steatosis grades of ≥ 1, ≥2, and 3 were 0.956 (95% confidence interval [CI], 0.910-1.00), 0.926 (95% CI, 0.860-0.993), and 0.971 (95% CI, 0.929-1.000), respectively. The UDFF cutoff value of > 6% had a sensitivity and specificity of 94.8% and 82.3%, respectively, for diagnosing steatosis grade ≥ 1. There was no association between UDFF and the fibrosis stage.

Conclusion: UDFF shows strong agreement with the histological fat content and excellent diagnostic accuracy for grading steatosis. UDFF is a promising tool for detecting and quantifying hepatic steatosis in clinical practice.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用超声波得出的脂肪分数检测和量化肝活检患者肝脂肪变性的诊断准确性。
目的:这项回顾性研究旨在探讨超声衍生脂肪分数(UDFF)在以肝组织学为参考标准对肝脏脂肪变性进行分级时的诊断准确性:方法:73 名肝病患者通过 UDFF 和肝活检进行了评估。采用皮尔逊检验和Bland-Altman图评估UDFF与肝脏切片组织学脂肪含量之间的相关性。利用接收者操作特征曲线下面积(AUROC)确定了组织学证实的脂肪变性等级的 UDFF 临界值:患者的中位年龄为 66 岁(四分位距为 54-74 岁),女性 33 人(占 45%)。随着脂肪变性等级的增加,UDFF值呈阶梯状增加(p 6%),诊断脂肪变性等级≥1的敏感性和特异性分别为94.8%和82.3%。结论:结论:UDFF与组织学脂肪含量高度一致,对脂肪变性分级具有极高的诊断准确性。在临床实践中,UDFF 是一种很有前途的检测和量化肝脂肪变性的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.30
自引率
11.10%
发文量
102
审稿时长
>12 weeks
期刊介绍: The Journal of Medical Ultrasonics is the official journal of the Japan Society of Ultrasonics in Medicine. The main purpose of the journal is to provide forum for the publication of papers documenting recent advances and new developments in the entire field of ultrasound in medicine and biology, encompassing both the medical and the engineering aspects of the science.The journal welcomes original articles, review articles, images, and letters to the editor.The journal also provides state-of-the-art information such as announcements from the boards and the committees of the society.
期刊最新文献
Correction: Principle of contrast-enhanced ultrasonography. Evaluation under loading detects medial meniscus extrusion in patients with reconstructed anterior cruciate ligament and restricted knee extension. Resolution of oval thrombus in a case of external jugular venous aneurysm. Quantification of the size of subchorionic hematoma causing pregnancy-related complications: a retrospective cohort study. Correction: Third-look contrast-enhanced ultrasonography plus needle biopsy for differential diagnosis of magnetic resonance imaging-only detected breast lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1