Micro-CT evaluation of the presence of voids in endodontic obturation.

Romina Loiacono, Ailín Gómez, María C González Clavín, Laura B Pinasco, Diego J Vázquez, Ariel F Gualtieri, Pablo A Rodríguez
{"title":"Micro-CT evaluation of the presence of voids in endodontic obturation.","authors":"Romina Loiacono, Ailín Gómez, María C González Clavín, Laura B Pinasco, Diego J Vázquez, Ariel F Gualtieri, Pablo A Rodríguez","doi":"10.54589/aol.37/1/3","DOIUrl":null,"url":null,"abstract":"<p><p>Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment.</p><p><strong>Aim: </strong>To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique.</p><p><strong>Materials and methods: </strong>Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis.</p><p><strong>Results: </strong>No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds.</p><p><strong>Conclusions: </strong>The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.</p>","PeriodicalId":93853,"journal":{"name":"Acta odontologica latinoamericana : AOL","volume":"37 1","pages":"3-12"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11277948/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta odontologica latinoamericana : AOL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54589/aol.37/1/3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment.

Aim: To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique.

Materials and methods: Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis.

Results: No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds.

Conclusions: The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对牙髓封固术中是否存在空隙进行显微 CT 评估。
目的:通过显微 CT 分析使用单锥和超声振动技术制备的下单根前磨牙根管封固术中是否存在空洞:选取 20 颗拔出的单根下前磨牙,通过手术和化学方法进行根管预备。第一组--无振动,使用单锥和生物陶瓷钝化根管,不使用振动。第 2 组--有振动,用棉钳夹住根管内的水门汀锥,然后进行 3 次超声振动,每次 3 秒钟。使用微型 CT 扫描仪获取和重建图像进行分析:结果:不同封堵技术之间没有发现明显差异,但不同三度之间存在差异,颈部三度的空隙比例高于中部和根尖三度:结果表明,使用超声波振动和不使用超声波振动的治疗方法在闭合性空洞、开放性空洞和总空洞的数量上没有差异。在牙颈部三分之一处,空隙量最大与所评估牙齿的椭圆形几何形状有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
0
期刊最新文献
Camouflaged prejudice and the affirmation of skin colour differences: assessment of racism among Brazilian undergraduate dental students. Changes in masseter muscle structure, membrane lipid peroxidation and Ca-ATPase activity as effects of different local anesthetics. Dental caries lesions and impact on quality of life in adolescents living in urban and rural areas. A case study. Effect of two oxygen-inhibiting agents on the surface microhardness of giomer restorative materials. Local application of melatonin associated or not to xenogeneic material, in critical defects of rat calvaria.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1