{"title":"Intraindividual Comparison of Dose Reduction and Coronary Calcium Scoring Accuracy Using Kilovolt-independent and Tin Filtration CT Protocols.","authors":"Salma Zook, Bhupendar Tayal, Kristian Kragholm, Ola Abdelkarim, Diana Tran, Myra Cocker, Juan Carlos Ramirez-Giraldo, Kristina Hallam, Colleen Sexton, Stephanie Johnson, Su Min Chang","doi":"10.1148/ryct.230246","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose To investigate the ability of kilovolt-independent (hereafter, kV-independent) and tin filter spectral shaping to accurately quantify the coronary artery calcium score (CACS) and radiation dose reductions compared with the standard 120-kV CT protocol. Materials and Methods This prospective, blinded reader study included 201 participants (mean age, 60 years ± 9.8 [SD]; 119 female, 82 male) who underwent standard 120-kV CT and additional kV-independent and tin filter research CT scans from October 2020 to July 2021. Scans were reconstructed using a Qr36f kernel for standard scans and an Sa36f kernel for research scans simulating artificial 120-kV images. CACS, risk categorization, and radiation doses were compared by analyzing data with analysis of variance, Kruskal-Wallis test, Mann-Whitney test, Bland-Altman analysis, Pearson correlations, and κ analysis for agreement. Results There was no evidence of differences in CACS across standard 120-kV, kV-independent, and tin filter scans, with median CACS values of 1 (IQR, 0-48), 0.6 (IQR, 0-58), and 0 (IQR, 0-51), respectively (<i>P</i> = .85). Compared with standard 120-kV scans, kV-independent and tin filter scans showed excellent correlation in CACS values (<i>r</i> = 0.993 and <i>r</i> = 0.999, respectively), with high agreement in CACS risk categorization (κ = 0.95 and κ = 0.93, respectively). Standard 120-kV scans had a mean radiation dose of 2.09 mSv ± 0.84, while kV-independent and tin filter scans reduced it to 1.21 mSv ± 0.85 and 0.26 mSv ± 0.11, cutting doses by 42% and 87%, respectively (<i>P</i> < .001). Conclusion The kV-independent and tin filter research CT acquisition techniques showed excellent agreement and high accuracy in CACS estimation compared with standard 120-kV scans, with large reductions in radiation dose. <b>Keywords:</b> CT, Cardiac, Coronary Arteries, Radiation Safety, Coronary Artery Calcium Score, Radiation Dose Reduction, Low-Dose CT Scan, Tin Filter, kV-Independent <i>Supplemental material is available for this article.</i> © RSNA, 2024.</p>","PeriodicalId":21168,"journal":{"name":"Radiology. Cardiothoracic imaging","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11211948/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology. Cardiothoracic imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1148/ryct.230246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
引用
批量引用
Abstract
Purpose To investigate the ability of kilovolt-independent (hereafter, kV-independent) and tin filter spectral shaping to accurately quantify the coronary artery calcium score (CACS) and radiation dose reductions compared with the standard 120-kV CT protocol. Materials and Methods This prospective, blinded reader study included 201 participants (mean age, 60 years ± 9.8 [SD]; 119 female, 82 male) who underwent standard 120-kV CT and additional kV-independent and tin filter research CT scans from October 2020 to July 2021. Scans were reconstructed using a Qr36f kernel for standard scans and an Sa36f kernel for research scans simulating artificial 120-kV images. CACS, risk categorization, and radiation doses were compared by analyzing data with analysis of variance, Kruskal-Wallis test, Mann-Whitney test, Bland-Altman analysis, Pearson correlations, and κ analysis for agreement. Results There was no evidence of differences in CACS across standard 120-kV, kV-independent, and tin filter scans, with median CACS values of 1 (IQR, 0-48), 0.6 (IQR, 0-58), and 0 (IQR, 0-51), respectively (P = .85). Compared with standard 120-kV scans, kV-independent and tin filter scans showed excellent correlation in CACS values (r = 0.993 and r = 0.999, respectively), with high agreement in CACS risk categorization (κ = 0.95 and κ = 0.93, respectively). Standard 120-kV scans had a mean radiation dose of 2.09 mSv ± 0.84, while kV-independent and tin filter scans reduced it to 1.21 mSv ± 0.85 and 0.26 mSv ± 0.11, cutting doses by 42% and 87%, respectively (P < .001). Conclusion The kV-independent and tin filter research CT acquisition techniques showed excellent agreement and high accuracy in CACS estimation compared with standard 120-kV scans, with large reductions in radiation dose. Keywords: CT, Cardiac, Coronary Arteries, Radiation Safety, Coronary Artery Calcium Score, Radiation Dose Reduction, Low-Dose CT Scan, Tin Filter, kV-Independent Supplemental material is available for this article. © RSNA, 2024.