Resilience of anodic biofilm in microbial fuel cell biosensor for BOD monitoring of urban wastewater

IF 10.4 1区 工程技术 Q1 ENGINEERING, CHEMICAL npj Clean Water Pub Date : 2024-06-28 DOI:10.1038/s41545-024-00350-5
Anna Salvian, Daniel Farkas, Marina Ramirez-Moreno, Daniela Torruella-Salas, Antonio Berná, Claudio Avignone-Rossa, John R. Varcoe, Abraham Esteve-Núñez, Siddharth Gadkari
{"title":"Resilience of anodic biofilm in microbial fuel cell biosensor for BOD monitoring of urban wastewater","authors":"Anna Salvian, Daniel Farkas, Marina Ramirez-Moreno, Daniela Torruella-Salas, Antonio Berná, Claudio Avignone-Rossa, John R. Varcoe, Abraham Esteve-Núñez, Siddharth Gadkari","doi":"10.1038/s41545-024-00350-5","DOIUrl":null,"url":null,"abstract":"Efficient wastewater treatment monitoring is vital for addressing water scarcity. Microbial fuel cells (MFCs) have emerged as real-time biosensors for biochemical oxygen demand (BOD) in urban wastewater. Discrepancies in signal generation may arise due to changes in the composition and metabolism of mixed-culture electroactive biofilms stemming from different wastewater compositions. In this study, 3D-printed MFC-based biosensors were employed to assess the BOD of sterile complex artificial wastewater and untreated urban wastewater. Alterations in the microbial composition of the anode were evaluated using 16S rRNA sequencing and metagenomics analysis. Results show that MFC-based biosensors can be effectively recalibrated for diverse types of wastewater, maintaining consistent sensitivity (0.64 ± 0.10 mA L mg−1 m−2 with synthetic wastewater and 0.78 ± 0.13 mA L mg−1 m−2 with urban wastewater) and limit of detection (49 ± 8 mg L−1 for synthetic wastewater and 44 ± 7 mg L−1 for urban wastewater). Crucially, pre-sterilization, conductivity adjustments, and nitrogen purging of wastewater are not required before its introduction into the biosensor. However, the presence of native aerobic microorganisms in the wastewater might affect the current output. Metagenomics and taxonomic analyses revealed that the alterations in biofilm composition are predominantly in response to the varied chemical and microbiological compositions of different substrates. Despite variations in anodic biofilm composition, the MFC-based biosensor maintains a relative error comparable to the standard BOD test. This highlights the resilience and flexibility of the biosensor when directly used with a variety of wastewater types before full biofilm adjustment.","PeriodicalId":19375,"journal":{"name":"npj Clean Water","volume":null,"pages":null},"PeriodicalIF":10.4000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.com/articles/s41545-024-00350-5.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Clean Water","FirstCategoryId":"5","ListUrlMain":"https://www.nature.com/articles/s41545-024-00350-5","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Efficient wastewater treatment monitoring is vital for addressing water scarcity. Microbial fuel cells (MFCs) have emerged as real-time biosensors for biochemical oxygen demand (BOD) in urban wastewater. Discrepancies in signal generation may arise due to changes in the composition and metabolism of mixed-culture electroactive biofilms stemming from different wastewater compositions. In this study, 3D-printed MFC-based biosensors were employed to assess the BOD of sterile complex artificial wastewater and untreated urban wastewater. Alterations in the microbial composition of the anode were evaluated using 16S rRNA sequencing and metagenomics analysis. Results show that MFC-based biosensors can be effectively recalibrated for diverse types of wastewater, maintaining consistent sensitivity (0.64 ± 0.10 mA L mg−1 m−2 with synthetic wastewater and 0.78 ± 0.13 mA L mg−1 m−2 with urban wastewater) and limit of detection (49 ± 8 mg L−1 for synthetic wastewater and 44 ± 7 mg L−1 for urban wastewater). Crucially, pre-sterilization, conductivity adjustments, and nitrogen purging of wastewater are not required before its introduction into the biosensor. However, the presence of native aerobic microorganisms in the wastewater might affect the current output. Metagenomics and taxonomic analyses revealed that the alterations in biofilm composition are predominantly in response to the varied chemical and microbiological compositions of different substrates. Despite variations in anodic biofilm composition, the MFC-based biosensor maintains a relative error comparable to the standard BOD test. This highlights the resilience and flexibility of the biosensor when directly used with a variety of wastewater types before full biofilm adjustment.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于监测城市污水生化需氧量的微生物燃料电池生物传感器中阳极生物膜的复原力
高效的废水处理监测对于解决水资源短缺问题至关重要。微生物燃料电池(MFC)已成为城市污水生化需氧量(BOD)的实时生物传感器。由于废水成分不同,混合培养的电活性生物膜的组成和新陈代谢可能会发生变化,从而导致信号产生的差异。本研究采用基于三维打印 MFC 的生物传感器来评估无菌复合人工废水和未经处理的城市污水的生化需氧量。使用 16S rRNA 测序和元基因组学分析评估了阳极微生物组成的变化。结果表明,基于 MFC 的生物传感器可针对不同类型的废水进行有效的重新校准,并保持一致的灵敏度(合成废水为 0.64 ± 0.10 mA L mg-1 m-2,城市污水为 0.78 ± 0.13 mA L mg-1 m-2)和检测限(合成废水为 49 ± 8 mg L-1,城市污水为 44 ± 7 mg L-1)。最重要的是,在将废水引入生物传感器之前,无需对废水进行预灭菌、电导率调整和氮气净化。不过,废水中存在的原生好氧微生物可能会影响电流输出。元基因组学和分类学分析表明,生物膜组成的变化主要是对不同基质的不同化学和微生物组成的反应。尽管阳极生物膜的组成发生了变化,但基于 MFC 的生物传感器仍能保持与标准 BOD 测试相当的相对误差。这突出表明,在生物膜完全调整之前,生物传感器可直接用于各种废水类型,具有很强的适应性和灵活性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
npj Clean Water
npj Clean Water Environmental Science-Water Science and Technology
CiteScore
15.30
自引率
2.60%
发文量
61
审稿时长
5 weeks
期刊介绍: npj Clean Water publishes high-quality papers that report cutting-edge science, technology, applications, policies, and societal issues contributing to a more sustainable supply of clean water. The journal's publications may also support and accelerate the achievement of Sustainable Development Goal 6, which focuses on clean water and sanitation.
期刊最新文献
Bacterial cellulose-graphene oxide composite membranes with enhanced fouling resistance for bio-effluents management Training caretakers to clean community wells is a highly cost-effective way to reduce exposure to coliform bacteria Uncovering pathway and mechanism of simultaneous thiocyanate detoxicity and nitrate removal through anammox and denitrification Author Correction: The enhancement of anammox by graphene-based and iron-based nanomaterials in performance and mechanisms Assessing the influence of environmental variables on energy efficiency changes in the provision of drinking water services
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1