Comparative analysis of a bulk optode based on a valinomycin ionophore and a nano-optode in micelles with pluronic F-127 for the quantification of potassium in aqueous solutions.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-07-01 DOI:10.1039/d4ay00581c
Miguel Villanueva, Jaime Vega-Chacón, Gino Picasso
{"title":"Comparative analysis of a bulk optode based on a valinomycin ionophore and a nano-optode in micelles with pluronic F-127 for the quantification of potassium in aqueous solutions.","authors":"Miguel Villanueva, Jaime Vega-Chacón, Gino Picasso","doi":"10.1039/d4ay00581c","DOIUrl":null,"url":null,"abstract":"<p><p>In this work, two types of optical sensors were prepared for the quantification of potassium: the bulk optode (BO) and nano-optode (NO). The BO was prepared using three main components: the ionophore valinomycin, the ion exchanger tetrakis(4-chlorophenyl) potassium borate (K-TCPB), and the chromoionophore ETH 5294 (CHI). The optimal composition was found to be in a ratio of [1 : 1 : 1]. The NO was prepared by miniaturizing the BO through sonication in surfactant Pluronic F-127. The working range for the linear calibration model of BO was from 10<sup>-6</sup> to 1.0 M K<sup>+</sup> with a LOD<sub>BO</sub> = 0.31 μM, meanwhile for NO was from 10<sup>-4</sup> to 1.0 M K<sup>+</sup> with a LOD<sub>NO</sub> = 30.3 μM. Both optodes were tested for selectivity towards K<sup>+</sup> in the presence of alkaline and alkaline earth ions, with a selectivity coefficient > 1.0. Furthermore, precision and stability studies of BO and NO were performed for three levels of K<sup>+</sup> concentrations, 10<sup>-6</sup>, 10<sup>-3</sup>, 1.0 M for BO and 10<sup>-4</sup>, 10<sup>-2</sup>, 1.0 M for NO, showing a good homogeneity of the NO in the whole concentration range. However, an excessive variability was obtained for BO at 1.0 M K<sup>+</sup>. Therefore, the NO represents a potential tool for quantification of K<sup>+</sup>.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay00581c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, two types of optical sensors were prepared for the quantification of potassium: the bulk optode (BO) and nano-optode (NO). The BO was prepared using three main components: the ionophore valinomycin, the ion exchanger tetrakis(4-chlorophenyl) potassium borate (K-TCPB), and the chromoionophore ETH 5294 (CHI). The optimal composition was found to be in a ratio of [1 : 1 : 1]. The NO was prepared by miniaturizing the BO through sonication in surfactant Pluronic F-127. The working range for the linear calibration model of BO was from 10-6 to 1.0 M K+ with a LODBO = 0.31 μM, meanwhile for NO was from 10-4 to 1.0 M K+ with a LODNO = 30.3 μM. Both optodes were tested for selectivity towards K+ in the presence of alkaline and alkaline earth ions, with a selectivity coefficient > 1.0. Furthermore, precision and stability studies of BO and NO were performed for three levels of K+ concentrations, 10-6, 10-3, 1.0 M for BO and 10-4, 10-2, 1.0 M for NO, showing a good homogeneity of the NO in the whole concentration range. However, an excessive variability was obtained for BO at 1.0 M K+. Therefore, the NO represents a potential tool for quantification of K+.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较分析基于缬氨霉素离子源的块状光电管和含有pluronic F-127胶束的纳米光电管在水溶液中的钾定量。
在这项工作中,我们制备了两种用于定量检测钾的光学传感器:块状光电极(BO)和纳米光电极(NO)。大块光电二极管(BO)由三种主要成分制备而成:离子体缬诺霉素、离子交换剂四(4-氯苯基)硼酸钾(K-TCPB)和发色团 ETH 5294(CHI)。最佳成分比例为 [1:1:1]。NO 是在表面活性剂 Pluronic F-127 中通过超声使 BO 微型化而制备的。BO 的线性校准模型工作范围为 10-6 至 1.0 M K+,LODBO = 0.31 μM;NO 的线性校准模型工作范围为 10-4 至 1.0 M K+,LODNO = 30.3 μM。在碱性离子和碱土离子存在的情况下,这两种光电二极管对 K+ 的选择性均大于 1.0。此外,还对三个 K+浓度水平(BO 为 10-6、10-3、1.0 M,NO 为 10-4、10-2、1.0 M)的 BO 和 NO 进行了精度和稳定性研究,结果表明 NO 在整个浓度范围内具有良好的均匀性。然而,在 1.0 M K+ 时,BO 的变异性过大。因此,NO 是一种潜在的 K+ 定量工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
Binary split fluorescent biosensor based on lettuce DNA aptamer for label-free and enzyme-free analysis of hepatitis B viral DNA. Determination of ethylene-bis-dithiocarbamates and their degradation product ethylenethiourea in dry herbs by UHPLC-MS/MS. Study on the creation of boronate affinity-based oriented imprinted silica nanoparticles and their selective recognition toward glycopeptide antibiotics in food and water. Transmission electron imaging and diffraction of asbestos fibers in a scanning electron microscope. A rapid and convenient sample treatment method based on the dissolvable polyacrylamide gel for S-acylation proteomics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1