Comparison of plasma clearance of [51Cr]CrEDTA based on three, two and single samples to measure the glomerular filtration rate in patients with solid tumors: a prospective cross-sectional analysis
Anne C. Gomes , George B. Coura Filho , Luiz A. Gil Junior , Renato A. Caires , Emmanuel A. Burdmann , Carlos A. Buchpiguel , Veronica T. Costa e Silva , Marcelo T. Sapienza
{"title":"Comparison of plasma clearance of [51Cr]CrEDTA based on three, two and single samples to measure the glomerular filtration rate in patients with solid tumors: a prospective cross-sectional analysis","authors":"Anne C. Gomes , George B. Coura Filho , Luiz A. Gil Junior , Renato A. Caires , Emmanuel A. Burdmann , Carlos A. Buchpiguel , Veronica T. Costa e Silva , Marcelo T. Sapienza","doi":"10.1016/j.clinsp.2024.100427","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>[<sup>51</sup>Cr]CrEDTA is used to measure the Glomerular Filtration Rate (GFR) in different clinical conditions. However, there is no consensus on the ideal number of blood samples to be taken and at what time points to measure its clearance. This study aimed to compare Slope Intercept (SI) and Single-Sample (SS) methods for measuring GFR in patients with solid tumors, stratified by age, GFR, and Body Mass Index (BMI).</p></div><div><h3>Methods</h3><p>1,174 patients with cancer were enrolled in this prospective study. GFR was calculated by the SI method using blood samples drawn 2-, 4-, and 6-hours after [<sup>51</sup>Cr]CrEDTA injection (246-GFR). GFR was also measured using the SI method with samples at 2 and 4 hours (24-GFR) and at 4 and 6 hours (46-GFR), and SS methods according to Groth (4Gr-GFR) and Fleming (4Fl-GFR). Statistical analysis was performed to assess the accuracy, precision, and bias of the methods.</p></div><div><h3>Results</h3><p>Mean 246-GFR was 79.2 ± 21.9 mL/min/1.73 m<sup>2</sup>. ANOVA indicated a significant difference between 4Gr-GFR and the reference 246-GFR. Bias was lower than 5 mL/min/1.73 m<sup>2</sup> for all methods, except for SS methods in subgroups BMI > 40 kg/m<sup>2</sup>; GFR > 105 or < 45. Precision was adequate and accuracy of 30 % was above 98% for all methods, except for SS methods in subgroup GFR < 45.</p></div><div><h3>Conclusion</h3><p>46-GFR and 246-GFR have high agreement and may be used to evaluate kidney function in patients with solid tumors. Single-sample methods can be adopted in specific situations, for non-obese patients with expected normal GFR.</p></div>","PeriodicalId":10472,"journal":{"name":"Clinics","volume":"79 ","pages":"Article 100427"},"PeriodicalIF":2.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1807593224001042/pdfft?md5=b0dc14970dc906a28748994c3cd941e0&pid=1-s2.0-S1807593224001042-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1807593224001042","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
[51Cr]CrEDTA is used to measure the Glomerular Filtration Rate (GFR) in different clinical conditions. However, there is no consensus on the ideal number of blood samples to be taken and at what time points to measure its clearance. This study aimed to compare Slope Intercept (SI) and Single-Sample (SS) methods for measuring GFR in patients with solid tumors, stratified by age, GFR, and Body Mass Index (BMI).
Methods
1,174 patients with cancer were enrolled in this prospective study. GFR was calculated by the SI method using blood samples drawn 2-, 4-, and 6-hours after [51Cr]CrEDTA injection (246-GFR). GFR was also measured using the SI method with samples at 2 and 4 hours (24-GFR) and at 4 and 6 hours (46-GFR), and SS methods according to Groth (4Gr-GFR) and Fleming (4Fl-GFR). Statistical analysis was performed to assess the accuracy, precision, and bias of the methods.
Results
Mean 246-GFR was 79.2 ± 21.9 mL/min/1.73 m2. ANOVA indicated a significant difference between 4Gr-GFR and the reference 246-GFR. Bias was lower than 5 mL/min/1.73 m2 for all methods, except for SS methods in subgroups BMI > 40 kg/m2; GFR > 105 or < 45. Precision was adequate and accuracy of 30 % was above 98% for all methods, except for SS methods in subgroup GFR < 45.
Conclusion
46-GFR and 246-GFR have high agreement and may be used to evaluate kidney function in patients with solid tumors. Single-sample methods can be adopted in specific situations, for non-obese patients with expected normal GFR.
期刊介绍:
CLINICS is an electronic journal that publishes peer-reviewed articles in continuous flow, of interest to clinicians and researchers in the medical sciences. CLINICS complies with the policies of funding agencies which request or require deposition of the published articles that they fund into publicly available databases. CLINICS supports the position of the International Committee of Medical Journal Editors (ICMJE) on trial registration.