Detectability of Breast Cancer in Dedicated Breast CT Compared With Mammography Dependent on Breast Density.

IF 7 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Investigative Radiology Pub Date : 2024-07-05 DOI:10.1097/RLI.0000000000001105
Matthias Wetzl, Theresa Heilingbrunner, Felix Heindl, Evelyn Wenkel, Michael Uder, Sabine Ohlmeyer
{"title":"Detectability of Breast Cancer in Dedicated Breast CT Compared With Mammography Dependent on Breast Density.","authors":"Matthias Wetzl, Theresa Heilingbrunner, Felix Heindl, Evelyn Wenkel, Michael Uder, Sabine Ohlmeyer","doi":"10.1097/RLI.0000000000001105","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the detectability of non-contrast-enhanced and contrast-enhanced spiral breast computed tomography ([non]-CE-SBCT) compared with mammography. Secondary objectives are to determine detectability depending on breast density and to evaluate appearance of breast malignancies according to BI-RADS descriptors.</p><p><strong>Methods: </strong>This retrospective institutional review board-approved study included 90 women with 105 biopsy-proven malignant breast lesions. Breast density, BI-RADS descriptors, and detectability were evaluated by 2 independent readers. Diagnostic confidence was rated on a 4-point Likert scale.</p><p><strong>Results: </strong>For readers 1 and 2, detectability was 83.8% and 80.0% for mammography, 99.1% and 99.1% for CE-SBCT ( P < 0.05), and 66.7% and 61.9% for non-CE-SBCT ( P < 0.05). With both readers, detectability in CE-SBCT was high for density A/B/C/D (both 100%/100%/100%/87.5%). Detectability of readers declined with increasing density for mammography (density A = 100%, B = 89.1% and 95.1%, C = 73.1%, D = 50.0% and 71.4%; P < 0.05) and for non-CE-SBCT (density A = 87.5% and 90.7%, B = 65.5% and 69.1%, C = 54.8% and 60.0%, D = 37.5%; P < 0.05). Mass lesions were detected with CT as often as with mammography, whereas architectural distortions and microcalcifications were detected less often with SBCT. Diagnostic confidence was very high or high in 97.2% for CE-SBCT, in 74.1% for non-CE-SBCT, and in 81.4% for mammography.</p><p><strong>Conclusions: </strong>Detectability and diagnostic confidence were very high in CE-SBCT, regardless of breast density. The detectability of non-CE-SBCT was lower than that of mammography and declined with increasing breast density.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":null,"pages":null},"PeriodicalIF":7.0000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001105","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the detectability of non-contrast-enhanced and contrast-enhanced spiral breast computed tomography ([non]-CE-SBCT) compared with mammography. Secondary objectives are to determine detectability depending on breast density and to evaluate appearance of breast malignancies according to BI-RADS descriptors.

Methods: This retrospective institutional review board-approved study included 90 women with 105 biopsy-proven malignant breast lesions. Breast density, BI-RADS descriptors, and detectability were evaluated by 2 independent readers. Diagnostic confidence was rated on a 4-point Likert scale.

Results: For readers 1 and 2, detectability was 83.8% and 80.0% for mammography, 99.1% and 99.1% for CE-SBCT ( P < 0.05), and 66.7% and 61.9% for non-CE-SBCT ( P < 0.05). With both readers, detectability in CE-SBCT was high for density A/B/C/D (both 100%/100%/100%/87.5%). Detectability of readers declined with increasing density for mammography (density A = 100%, B = 89.1% and 95.1%, C = 73.1%, D = 50.0% and 71.4%; P < 0.05) and for non-CE-SBCT (density A = 87.5% and 90.7%, B = 65.5% and 69.1%, C = 54.8% and 60.0%, D = 37.5%; P < 0.05). Mass lesions were detected with CT as often as with mammography, whereas architectural distortions and microcalcifications were detected less often with SBCT. Diagnostic confidence was very high or high in 97.2% for CE-SBCT, in 74.1% for non-CE-SBCT, and in 81.4% for mammography.

Conclusions: Detectability and diagnostic confidence were very high in CE-SBCT, regardless of breast density. The detectability of non-CE-SBCT was lower than that of mammography and declined with increasing breast density.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
专用乳腺 CT 与乳腺 X 射线照相术对乳腺癌的检测能力取决于乳腺密度。
目的评估非对比度增强型和对比度增强型螺旋乳腺计算机断层扫描([non]-CE-SBCT)与乳腺放射摄影的可探测性。次要目标是根据乳腺密度确定可探测性,并根据 BI-RADS 描述评估乳腺恶性肿瘤的外观:这项经机构审查委员会批准的回顾性研究包括 90 名妇女,她们有 105 个经活检证实的乳腺恶性病变。由两名独立读者对乳腺密度、BI-RADS描述指标和可探测性进行评估。诊断信心采用 4 点李克特量表评分:对于读者 1 和读者 2,乳腺 X 射线摄影的可探测性分别为 83.8% 和 80.0%,CE-SBCT 的可探测性分别为 99.1% 和 99.1%(P < 0.05),非 CE-SBCT 的可探测性分别为 66.7% 和 61.9%(P < 0.05)。使用两种读取器,CE-SBCT 对密度 A/B/C/D 的检出率都很高(均为 100%/100%/100%/87.5%)。对于乳腺 X 线照相术(密度 A = 100%,B = 89.1% 和 95.1%,C = 73.1%,D = 50.0% 和 71.4%;P <0.05)和非 CE-SBCT (密度 A = 87.5% 和 90.7%,B = 65.5% 和 69.1%,C = 54.8% 和 60.0%,D = 37.5%;P <0.05),读者的检出率随着密度的增加而下降。CT 与乳腺 X 射线照相一样能发现肿块病变,而 SBCT 则较少发现建筑变形和微小钙化。97.2%的 CE-SBCT 诊断可信度很高或很高,74.1%的非 CE-SBCT 诊断可信度很高或很高,81.4%的乳腺放射摄影诊断可信度很高或很高:结论:无论乳腺密度如何,CE-SBCT 的检出率和诊断可信度都非常高。结论:无论乳腺密度如何,CE-SBCT 的检出率和诊断可信度都非常高,而非 CE-SBCT 的检出率低于乳腺 X 线照相术,并且随着乳腺密度的增加而下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
期刊最新文献
Editorial: Hot Topics in Diagnostic Imaging-Encompassing Advances in MR, Photon-Counting CT, and Ultrasound. Implementation of an AI Algorithm in Clinical Practice to Reduce Missed Incidental Pulmonary Embolisms on Chest CT and Its Impact on Short-Term Survival. Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries: Comparison to Iodine in a Cardiovascular Phantom. Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study. Countering Calcium Blooming With Personalized Contrast Media Injection Protocols: The 1-2-3 Rule for Photon-Counting Detector CCTA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1