Comparison of the effectiveness of contrast-enhanced mammography in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.

Polish journal of radiology Pub Date : 2024-05-15 eCollection Date: 2024-01-01 DOI:10.5114/pjr/186180
Anna Grażyńska, Agnieszka Niewiadomska, Aleksander J Owczarek, Mateusz Winder, Jakub Hołda, Olga Zwolińska, Anna Barczyk-Gutkowska, Sandra Modlińska, Andrzej Lorek, Aleksandra Kuźbińska, Katarzyna Steinhof-Radwańska
{"title":"Comparison of the effectiveness of contrast-enhanced mammography in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.","authors":"Anna Grażyńska, Agnieszka Niewiadomska, Aleksander J Owczarek, Mateusz Winder, Jakub Hołda, Olga Zwolińska, Anna Barczyk-Gutkowska, Sandra Modlińska, Andrzej Lorek, Aleksandra Kuźbińska, Katarzyna Steinhof-Radwańska","doi":"10.5114/pjr/186180","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the effectiveness of contrast-enhanced mammography (CEM) recombinant images in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.</p><p><strong>Material and methods: </strong>792 patients with 808 breast lesions, in whom the final decision on core-needle biopsy was made based on CEM, and who received the result of histopathological examination, were qualified for a single-centre, retrospective study. Patient electronic records and imaging examinations were reviewed to establish demographics, clinical and imaging findings, and histopathology results. The CEM images were reassessed and assigned to the appropriate American College of Radiology (ACR) density categories.</p><p><strong>Results: </strong>Extremely dense breasts were present in 86 (10.9%) patients. Histopathological examination confirmed the presence of malignant lesions in 52.6% of cases in the entire group of patients and 43% in the group of extremely dense breasts. CEM incorrectly classified the lesion as false negative in 16/425 (3.8%) cases for the whole group, and in 1/37 (2.7%) cases for extremely dense breasts. The sensitivity of CEM for the group of all patients was 96.2%, specificity - 60%, positive predictive values (PPV) - 72.8%, and negative predictive values (NPV) - 93.5%. In the group of patients with extremely dense breasts, the sensitivity of the method was 97.3%, specificity - 59.2%, PPV - 64.3%, and NPV - 96.7%.</p><p><strong>Conclusions: </strong>CEM is characterised by high sensitivity and NPV in detecting malignant lesions regardless of the type of breast density. In patients with extremely dense breasts, CEM could serve as a complementary or additional examination in the absence or low availability of MRI.</p>","PeriodicalId":94174,"journal":{"name":"Polish journal of radiology","volume":"89 ","pages":"e240-e248"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11210381/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish journal of radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr/186180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the effectiveness of contrast-enhanced mammography (CEM) recombinant images in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.

Material and methods: 792 patients with 808 breast lesions, in whom the final decision on core-needle biopsy was made based on CEM, and who received the result of histopathological examination, were qualified for a single-centre, retrospective study. Patient electronic records and imaging examinations were reviewed to establish demographics, clinical and imaging findings, and histopathology results. The CEM images were reassessed and assigned to the appropriate American College of Radiology (ACR) density categories.

Results: Extremely dense breasts were present in 86 (10.9%) patients. Histopathological examination confirmed the presence of malignant lesions in 52.6% of cases in the entire group of patients and 43% in the group of extremely dense breasts. CEM incorrectly classified the lesion as false negative in 16/425 (3.8%) cases for the whole group, and in 1/37 (2.7%) cases for extremely dense breasts. The sensitivity of CEM for the group of all patients was 96.2%, specificity - 60%, positive predictive values (PPV) - 72.8%, and negative predictive values (NPV) - 93.5%. In the group of patients with extremely dense breasts, the sensitivity of the method was 97.3%, specificity - 59.2%, PPV - 64.3%, and NPV - 96.7%.

Conclusions: CEM is characterised by high sensitivity and NPV in detecting malignant lesions regardless of the type of breast density. In patients with extremely dense breasts, CEM could serve as a complementary or additional examination in the absence or low availability of MRI.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对比造影剂增强型乳腺 X 射线照相术在检测极致密乳房患者恶性病变方面与所有致密人群的效果。
目的:与所有致密人群相比,评估造影剂增强乳腺X线摄影(CEM)重组图像在检测极致密乳房患者恶性病变方面的有效性。材料与方法:792例808个乳房病变的患者符合单中心回顾性研究的条件,这些患者根据CEM最终决定进行核心针活检,并获得了组织病理学检查结果。研究人员查阅了患者的电子病历和影像学检查,以确定人口统计学、临床和影像学检查结果以及组织病理学检查结果。对CEM图像进行重新评估,并将其归入相应的美国放射学会(ACR)密度类别:结果:86 例(10.9%)患者的乳房密度极高。组织病理学检查证实,整组患者中有 52.6% 的病例存在恶性病变,极致密乳房组中有 43% 的病例存在恶性病变。在整组患者中,CEM 错误地将病变归类为假阴性的有 16/425 例(3.8%),在极致密乳房患者中,CEM 错误地将病变归类为假阴性的有 1/37 例(2.7%)。在所有患者中,CEM 的灵敏度为 96.2%,特异性为 60%,阳性预测值 (PPV) 为 72.8%,阴性预测值 (NPV) 为 93.5%。在乳房密度极高的患者组中,该方法的灵敏度为 97.3%,特异性为 59.2%,PPV 为 64.3%,NPV 为 96.7%:无论乳腺密度类型如何,CEM 在检测恶性病变方面都具有高灵敏度和 NPV 的特点。对于乳腺密度极高的患者,CEM可在没有磁共振成像或磁共振成像可用性低的情况下作为补充或额外检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Advancing radiology education for medical students: leveraging digital tools and resources. Application of ultrasound-guided intranodal lymphangiography in the diagnosis and treatment of chylous ascites after abdominal surgery. Medication-induced changes on magnetic resonance imaging of the brain. The peritumoral brain zone in glioblastoma: a review of the pretreatment approach. Comparative efficacy of contrast-enhanced ultrasound versus B-mode ultrasound in the diagnosis and monitoring of hepatic abscesses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1