{"title":"Biomechanical Effects of Titanium and Carbon Fiber Reinforced PEEK as Dental Implant Material: A Finite Element Analysis.","authors":"Engin Ediboğlu, Sıdıka Sinem Akdeniz, Esra Beyler","doi":"10.11607/jomi.10954","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study is to examine the stresses on the peri-implant bone under occlusal forces of 30% Carbon fiber reinforced PEEK (Cfr-PEEK) and 60% Cfr-PEEK materials that can be used as an alternative to titanium dental implants by finite element analysis.</p><p><strong>Materials and methods: </strong>Single-tooth implants of 30% Cfr-PEEK, 60% Cfr-PEEK and titanium were modeled in each of the maxillary anterior, maxilla posterior, mandibular posterior regions. As a result of the applied vertical and oblique forces; Von Misses stress, maximum principal stress and minimum principal stress values and stress distributions in the implant, cortical bone and spongious bone in each of the models were examined.</p><p><strong>Results: </strong>30% Cfr-PEEK implants stress in the surrounding bone was higher than titanium and 60% Cfr-PEEK implants. The 60% Cfr-PEEK material displayed lower stress distribution on both cortical and spongious peri-implant bone in all models.</p><p><strong>Conclusion: </strong>Titanium and 60% Cfr- PEEK implants exhibited biomechanically similar behavior and these implants conducted stresses to bone more homogeneous than the 30% Cfr-PEEK implants. Overall, oblique forces had more destructive effect than vertical forces and denser bone structure showed better stress distribution against incoming forces. For the routine use of Cfr-PEEK material as dental implant material; animal and long-term clinical studies are needed.</p>","PeriodicalId":94230,"journal":{"name":"The International journal of oral & maxillofacial implants","volume":"0 0","pages":"1-17"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral & maxillofacial implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/jomi.10954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study is to examine the stresses on the peri-implant bone under occlusal forces of 30% Carbon fiber reinforced PEEK (Cfr-PEEK) and 60% Cfr-PEEK materials that can be used as an alternative to titanium dental implants by finite element analysis.

Materials and methods: Single-tooth implants of 30% Cfr-PEEK, 60% Cfr-PEEK and titanium were modeled in each of the maxillary anterior, maxilla posterior, mandibular posterior regions. As a result of the applied vertical and oblique forces; Von Misses stress, maximum principal stress and minimum principal stress values and stress distributions in the implant, cortical bone and spongious bone in each of the models were examined.

Results: 30% Cfr-PEEK implants stress in the surrounding bone was higher than titanium and 60% Cfr-PEEK implants. The 60% Cfr-PEEK material displayed lower stress distribution on both cortical and spongious peri-implant bone in all models.

Conclusion: Titanium and 60% Cfr- PEEK implants exhibited biomechanically similar behavior and these implants conducted stresses to bone more homogeneous than the 30% Cfr-PEEK implants. Overall, oblique forces had more destructive effect than vertical forces and denser bone structure showed better stress distribution against incoming forces. For the routine use of Cfr-PEEK material as dental implant material; animal and long-term clinical studies are needed.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
钛和碳纤维增强聚醚醚酮作为牙科植入材料的生物力学效应:有限元分析
目的:本研究的目的是通过有限元分析,研究30%碳纤维增强PEEK(Cfr-PEEK)和60%Cfr-PEEK材料在咬合力作用下对种植体周围牙槽骨的应力:分别在上颌前部、上颌后部和下颌后部对 30% Cfr-PEEK、60% Cfr-PEEK 和钛的单牙种植体进行建模。在垂直和倾斜力作用下,对每个模型的 Von Misses 应力、最大主应力和最小主应力值以及种植体、皮质骨和海绵骨中的应力分布进行了研究:结果:30% Cfr-PEEK 种植体在周围骨中的应力高于钛和 60% Cfr-PEEK 种植体。在所有模型中,60% Cfr-PEEK 材料在皮质和海绵状种植体周围骨中的应力分布都较低:结论:钛和 60% Cfr-PEEK 种植体表现出相似的生物力学行为,与 30% Cfr-PEEK 种植体相比,这些种植体对骨的应力传导更为均匀。总体而言,斜向作用力比垂直作用力更具破坏性,而密度较高的骨结构对传入作用力的应力分布更好。要将 Cfr-PEEK 材料常规用作牙科植入材料,还需要进行动物实验和长期临床研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Horizontal Guided Bone Regeneration: L-PRF Bone-Block Vs A Mixture of Autogenous Bone with Deproteinized Bovine Bone Mineral. A Split-Mouth RCT Study with 25 Months Follow-Up. Influence of Dental Implant Diameters on Prosthesis Complications: a Systematic Review and Meta-analysis. Qualitative Analysis of Implant-Bone Interface After Implant Placement Implementing Condensation Technique In Vitro. Thermal Changes During Digital Guided Implant Surgery Using the Conventional and Single Drill Protocols. Effect of Primary Stability on Short vs. Conventional -Implants with Reverse Concave Neck.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1