Quantification of the contribution of individual coagulation factors to haemostasis using a microchip flow chamber system and reconstituted blood from deficient plasma.
{"title":"Quantification of the contribution of individual coagulation factors to haemostasis using a microchip flow chamber system and reconstituted blood from deficient plasma.","authors":"Akihiro Fuchizaki, Kazuta Yasui, Tomoya Hayashi, Yoshihiro Fujimura, Chiaki Oyamada, Tomoko Ohnishi-Wada, Kazuya Hosokawa, Kazushige Shimogaki, Takafumi Kimura, Fumiya Hirayama, Yoshihiro Takihara","doi":"10.1111/vox.13709","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Quantifying the contribution of individual coagulation factors to haemostasis may aid our understanding of the haemostatic function in patients with rare coagulation deficiencies (RCDs) and the exploration of suitable treatments.</p><p><strong>Materials and methods: </strong>Reconstituted blood prepared from specific coagulation factor-deficient plasma (factor [F]II; prothrombin, FV, FVII, FVIII, FIX, FX, FXI or FXII) and red blood cell/platelet products were used to simulate the whole blood of patients with RCD. We prepared in vitro treatment models for patients with prothrombin deficiency using coagulation factor agents and fresh frozen plasma. Haemostatic function was measured using a microchip flow chamber system at 600 s<sup>-1</sup>.</p><p><strong>Results: </strong>The haemostatic function was low, especially in blood samples reconstituted with prothrombin- and FX-deficient plasma. In a plasma transfusion model of prothrombin deficiency, haemostatic function recovered after 10% replacement with normal plasma and reached a plateau at ≧60% replacement. A treatment model of prothrombin deficiency with prothrombin complex concentrates revealed dose-dependent therapeutic effects in the range of 0-50 IU/kg.</p><p><strong>Conclusion: </strong>Microchip flow chamber system-based quantification of haemostatic function using reconstituted blood could predict haemostasis and therapeutic effects of treatments in patients with prothrombin deficiency.</p>","PeriodicalId":23631,"journal":{"name":"Vox Sanguinis","volume":" ","pages":"1065-1071"},"PeriodicalIF":1.8000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vox Sanguinis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/vox.13709","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objectives: Quantifying the contribution of individual coagulation factors to haemostasis may aid our understanding of the haemostatic function in patients with rare coagulation deficiencies (RCDs) and the exploration of suitable treatments.
Materials and methods: Reconstituted blood prepared from specific coagulation factor-deficient plasma (factor [F]II; prothrombin, FV, FVII, FVIII, FIX, FX, FXI or FXII) and red blood cell/platelet products were used to simulate the whole blood of patients with RCD. We prepared in vitro treatment models for patients with prothrombin deficiency using coagulation factor agents and fresh frozen plasma. Haemostatic function was measured using a microchip flow chamber system at 600 s-1.
Results: The haemostatic function was low, especially in blood samples reconstituted with prothrombin- and FX-deficient plasma. In a plasma transfusion model of prothrombin deficiency, haemostatic function recovered after 10% replacement with normal plasma and reached a plateau at ≧60% replacement. A treatment model of prothrombin deficiency with prothrombin complex concentrates revealed dose-dependent therapeutic effects in the range of 0-50 IU/kg.
Conclusion: Microchip flow chamber system-based quantification of haemostatic function using reconstituted blood could predict haemostasis and therapeutic effects of treatments in patients with prothrombin deficiency.
期刊介绍:
Vox Sanguinis reports on important, novel developments in transfusion medicine. Original papers, reviews and international fora are published on all aspects of blood transfusion and tissue transplantation, comprising five main sections:
1) Transfusion - Transmitted Disease and its Prevention:
Identification and epidemiology of infectious agents transmissible by blood;
Bacterial contamination of blood components;
Donor recruitment and selection methods;
Pathogen inactivation.
2) Blood Component Collection and Production:
Blood collection methods and devices (including apheresis);
Plasma fractionation techniques and plasma derivatives;
Preparation of labile blood components;
Inventory management;
Hematopoietic progenitor cell collection and storage;
Collection and storage of tissues;
Quality management and good manufacturing practice;
Automation and information technology.
3) Transfusion Medicine and New Therapies:
Transfusion thresholds and audits;
Haemovigilance;
Clinical trials regarding appropriate haemotherapy;
Non-infectious adverse affects of transfusion;
Therapeutic apheresis;
Support of transplant patients;
Gene therapy and immunotherapy.
4) Immunohaematology and Immunogenetics:
Autoimmunity in haematology;
Alloimmunity of blood;
Pre-transfusion testing;
Immunodiagnostics;
Immunobiology;
Complement in immunohaematology;
Blood typing reagents;
Genetic markers of blood cells and serum proteins: polymorphisms and function;
Genetic markers and disease;
Parentage testing and forensic immunohaematology.
5) Cellular Therapy:
Cell-based therapies;
Stem cell sources;
Stem cell processing and storage;
Stem cell products;
Stem cell plasticity;
Regenerative medicine with cells;
Cellular immunotherapy;
Molecular therapy;
Gene therapy.