{"title":"Investigation of Different Miniscrew Head Designs by Finite Element Analysis.","authors":"Samet Çıklaçandır, Gökçenur Gökçe Kara, Yalçın İşler","doi":"10.4274/TurkJOrthod.2023.2022.189","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the optimum miniscrew head design in orthodontic treatments for primary stability and compare stress distribution on a representative bone structure.</p><p><strong>Methods: </strong>Miniscrews with cross heads, mushroom-shaped heads, button heads, bracket heads, and through-hole heads were compared using finite element analysis. Miniscrews, whose three-dimensional drawings were completed using the SolidWorks computer-aided software package, were inserted in the bone block. Orthodontic force was applied to the head, and stress distributions, strains, and total deformations were investigated.</p><p><strong>Results: </strong>The lowest von Mises stress of 5.67 MPa was obtained using the bracket head. On the other hand, the highest von Mises stress of 22.4 MPa was found with the button head. Through mesh convergence analysis, the most appropriate mesh size was determined to be 0.5 mm; approximately 230,000 elements were formed for each model.</p><p><strong>Conclusion: </strong>Because the need for low stress is substantial for the primary stability of the miniscrew, this study demonstrated that the bracket head miniscrew is the optimal head design. In addition, it is posited that the success rate of orthodontic anchorage treatments will increase when bracket head miniscrews are used.</p>","PeriodicalId":37013,"journal":{"name":"Turkish Journal of Orthodontics","volume":"37 2","pages":"98-103"},"PeriodicalIF":0.8000,"publicationDate":"2024-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11589244/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/TurkJOrthod.2023.2022.189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To determine the optimum miniscrew head design in orthodontic treatments for primary stability and compare stress distribution on a representative bone structure.

Methods: Miniscrews with cross heads, mushroom-shaped heads, button heads, bracket heads, and through-hole heads were compared using finite element analysis. Miniscrews, whose three-dimensional drawings were completed using the SolidWorks computer-aided software package, were inserted in the bone block. Orthodontic force was applied to the head, and stress distributions, strains, and total deformations were investigated.

Results: The lowest von Mises stress of 5.67 MPa was obtained using the bracket head. On the other hand, the highest von Mises stress of 22.4 MPa was found with the button head. Through mesh convergence analysis, the most appropriate mesh size was determined to be 0.5 mm; approximately 230,000 elements were formed for each model.

Conclusion: Because the need for low stress is substantial for the primary stability of the miniscrew, this study demonstrated that the bracket head miniscrew is the optimal head design. In addition, it is posited that the success rate of orthodontic anchorage treatments will increase when bracket head miniscrews are used.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过有限元分析研究不同的微型螺旋头设计
目的确定在正畸治疗中实现初级稳定性的最佳微型螺钉头设计,并比较代表性骨结构上的应力分布:采用有限元分析法比较了十字头、蘑菇头、按钮头、托槽头和通孔头的微型螺钉。使用 SolidWorks 计算机辅助软件包完成了微型螺钉的三维绘图,并将其插入骨块中。对头部施加正畸力,并研究应力分布、应变和总变形:结果:使用托槽头获得的最低 von Mises 应力为 5.67 兆帕。另一方面,扣式封头的 von Mises 应力最大,为 22.4 兆帕。通过网格收敛分析,确定最合适的网格尺寸为 0.5 毫米;每个模型都形成了约 230,000 个元素:由于微型螺钉的主要稳定性对低应力的需求很大,本研究表明,托架头微型螺钉是最佳的头部设计。此外,还假设使用托槽头微型螺钉后,正畸锚固治疗的成功率将会提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Turkish Journal of Orthodontics
Turkish Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.10
自引率
9.10%
发文量
34
期刊最新文献
Bibliometric Analysis of Maxillary Expansion Publications Trends. Corrosion Behavior of Nickel-Titanium Arch Wires Following the Use of Different Mouthwashes: An In Vivo Study. Effect of Different Liquids and Thermal Aging Procedures on the Shear Bond Strength of APC II, APC Flash-Free, and Conventional Ceramic Brackets: An In Vitro Study. Evaluation of Maxillary Protraction Using a Mini Screw-Retained Palatal C-Shaped Plate and Face Mask. Evaluation of the Effects of Orthopedic Treatment on the Dentofacial Structure and Upper Airway of Subjects with Skeletal Class III Malocclusion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1