{"title":"Assessing the efficacy of electrolyzed water for sanitizing contaminated stainless-steel surfaces in the meat industry","authors":"Nurul Izzah Khalid , Nurul Shaqirah Sulaiman , Norashikin Ab Aziz , Farah Saleena Taip , Mahmud Ab Rashid Nor-Khaizura , Shafreeza Sobri , Muhamad Hafiz Abd Rahim","doi":"10.1016/j.jfoodeng.2024.112199","DOIUrl":null,"url":null,"abstract":"<div><p>Electrolyzed water (EW) presents promising potential as an alternative sanitation solution, offering cost savings and eliminating the need for harsh chemicals in food factories. This study investigates EW's efficacy in cleaning contaminated stainless-steel plates. Some plates were covered with meat residues, and the upper side of the plate's surfaces were inoculated with <em>Escherichia coli</em> ATCC 10536. Plates were then immersed in sterile distilled water (SDW) (pH: 7 ± 1), acidic electrolyzed water (AcEW) (free chlorine: 4.21 ± 0.05 mg/L, oxidation-reduction potential (ORP): 1168 ± 3.54 mV, pH: 2.74 ± 0.03), or alkaline electrolyzed water (AlEW) (ORP: 817 ± 8.49 mV, pH: 11.38 ± 0.01), at different temperatures (30 or 50 °C) for 30 s. The cleanliness of plates was confirmed microbiologically when no <em>E</em>. <em>coli</em> was detected, (below 1.0 log CFU/cm<sup>2</sup>). Treatment with SDW resulted in a modest reduction of the <em>E. coli</em> by 1.67 ± 0.84 log CFU/cm<sup>2</sup> (±70% of the survived population). At 30 °C, <em>E. coli</em> was undetectable when AlEW was used without meat residue. At 50 °C, <em>E. coli</em> was undetectable when either AcEW or AlEW was used without meat residue. Visual and tactile inspections were conducted to validate cleanliness. The visual examination was performed after cleaning the plates with EW to ensure they appeared clean. However, tactile inspection indicated the presence of residues. Subsequent microbial analysis revealed 1.50 ± 0.87 log CFU/100 cm<sup>2</sup> (±36% of the surviving population) of <em>E. coli</em>. This study demonstrated that meat residues on food-contact surfaces create a barrier to sanitation, necessitating mechanical action and heat for improved cleanliness.</p></div>","PeriodicalId":359,"journal":{"name":"Journal of Food Engineering","volume":null,"pages":null},"PeriodicalIF":5.3000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Engineering","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0260877424002656","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Electrolyzed water (EW) presents promising potential as an alternative sanitation solution, offering cost savings and eliminating the need for harsh chemicals in food factories. This study investigates EW's efficacy in cleaning contaminated stainless-steel plates. Some plates were covered with meat residues, and the upper side of the plate's surfaces were inoculated with Escherichia coli ATCC 10536. Plates were then immersed in sterile distilled water (SDW) (pH: 7 ± 1), acidic electrolyzed water (AcEW) (free chlorine: 4.21 ± 0.05 mg/L, oxidation-reduction potential (ORP): 1168 ± 3.54 mV, pH: 2.74 ± 0.03), or alkaline electrolyzed water (AlEW) (ORP: 817 ± 8.49 mV, pH: 11.38 ± 0.01), at different temperatures (30 or 50 °C) for 30 s. The cleanliness of plates was confirmed microbiologically when no E. coli was detected, (below 1.0 log CFU/cm2). Treatment with SDW resulted in a modest reduction of the E. coli by 1.67 ± 0.84 log CFU/cm2 (±70% of the survived population). At 30 °C, E. coli was undetectable when AlEW was used without meat residue. At 50 °C, E. coli was undetectable when either AcEW or AlEW was used without meat residue. Visual and tactile inspections were conducted to validate cleanliness. The visual examination was performed after cleaning the plates with EW to ensure they appeared clean. However, tactile inspection indicated the presence of residues. Subsequent microbial analysis revealed 1.50 ± 0.87 log CFU/100 cm2 (±36% of the surviving population) of E. coli. This study demonstrated that meat residues on food-contact surfaces create a barrier to sanitation, necessitating mechanical action and heat for improved cleanliness.
期刊介绍:
The journal publishes original research and review papers on any subject at the interface between food and engineering, particularly those of relevance to industry, including:
Engineering properties of foods, food physics and physical chemistry; processing, measurement, control, packaging, storage and distribution; engineering aspects of the design and production of novel foods and of food service and catering; design and operation of food processes, plant and equipment; economics of food engineering, including the economics of alternative processes.
Accounts of food engineering achievements are of particular value.