Sophia S Goller, Georg W Kajdi, Georg C Feuerriegel, Reto Sutter
{"title":"Radiopalmar ganglion cysts: prevalence, morphology, and clinical significance in wrist MRI.","authors":"Sophia S Goller, Georg W Kajdi, Georg C Feuerriegel, Reto Sutter","doi":"10.1007/s00330-024-10884-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess radiopalmar ganglion cysts' (RPG) prevalence, morphology, and clinical significance in consecutive patients.</p><p><strong>Materials and methods: </strong>In this retrospective single-center study, two radiologists assessed the presence of RPG and morphologic features on wrist MRI. Radiopalmar complaints and scapholunate ligament (SLL) tears were evaluated.</p><p><strong>Results: </strong>A total of 1053 wrists in 909 patients (mean age 43.4 ± 15.5 years, 602 females) were evaluated. All 308 RPG (Group 1; 308 patients, 29.2%) originated from the palmar capsule; 49 were unilocular, 95 oligolocular, and 164 multilocular; 745 wrists had no RPG (Group 2; 601 patients). One hundred and twenty-six RPG showed internal debris. The mean diameter was 8.5 ± 5.6 mm (cranio-caudal) (1.0-32.9 mm), 8.0 ± 4.1 mm (medio-lateral) (1.0-31.9 mm), and 3.7 ± 2.3 mm (dorso-palmar) (0.4-16.0 mm). 168 RPG showed direct contact with the radial vascular bundle, 24 with the flexor carpi radialis tendon, and 123 with the flexor pollicis longus tendon. In Group 1, significantly more patients showed partial (82/308) [group 2: 45/745, p < 0.001] or complete SLL tears (22/308) [group 2: 20/745, p < 0.001]. Of the patients with RPG, 15.3% presented with radiopalmar complaints. Only the dorso-palmar RPG diameter was positively correlated with radiopalmar complaints (for readers 1 and 2: r<sub>s</sub> = 0.66/0.61, p < 0.001, respectively), and the best dorso-palmar diameter cut-off value for the probability of having radiopalmar complaints was defined at 3 mm (area under the curve (AUC) 0.74). Other morphologic features were not eligible to discriminate symptomatic patients (AUC range 0.53-0.61).</p><p><strong>Conclusion: </strong>This study found RPG in 29% of patients, most of them asymptomatic. However, a dorso-palmar cyst diameter > 3 mm may be clinically significant.</p><p><strong>Clinical relevance statement: </strong>Radiopalmar ganglion cysts, observed in 29% of wrist MR examinations, are mostly asymptomatic, but those with a larger dorso-palmar diameter may be associated with radiopalmar complaints.</p><p><strong>Key points: </strong>Radiopalmar ganglion cysts are found in 29% of patients undergoing wrist MRI. Most patients with evidence of radiopalmar ganglion cysts do not show radiopalmar symptoms (85%). A dorso-palmar cyst diameter > 3 mm may be associated with radiopalmar complaints.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":"7869-7877"},"PeriodicalIF":4.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11557648/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-024-10884-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To assess radiopalmar ganglion cysts' (RPG) prevalence, morphology, and clinical significance in consecutive patients.
Materials and methods: In this retrospective single-center study, two radiologists assessed the presence of RPG and morphologic features on wrist MRI. Radiopalmar complaints and scapholunate ligament (SLL) tears were evaluated.
Results: A total of 1053 wrists in 909 patients (mean age 43.4 ± 15.5 years, 602 females) were evaluated. All 308 RPG (Group 1; 308 patients, 29.2%) originated from the palmar capsule; 49 were unilocular, 95 oligolocular, and 164 multilocular; 745 wrists had no RPG (Group 2; 601 patients). One hundred and twenty-six RPG showed internal debris. The mean diameter was 8.5 ± 5.6 mm (cranio-caudal) (1.0-32.9 mm), 8.0 ± 4.1 mm (medio-lateral) (1.0-31.9 mm), and 3.7 ± 2.3 mm (dorso-palmar) (0.4-16.0 mm). 168 RPG showed direct contact with the radial vascular bundle, 24 with the flexor carpi radialis tendon, and 123 with the flexor pollicis longus tendon. In Group 1, significantly more patients showed partial (82/308) [group 2: 45/745, p < 0.001] or complete SLL tears (22/308) [group 2: 20/745, p < 0.001]. Of the patients with RPG, 15.3% presented with radiopalmar complaints. Only the dorso-palmar RPG diameter was positively correlated with radiopalmar complaints (for readers 1 and 2: rs = 0.66/0.61, p < 0.001, respectively), and the best dorso-palmar diameter cut-off value for the probability of having radiopalmar complaints was defined at 3 mm (area under the curve (AUC) 0.74). Other morphologic features were not eligible to discriminate symptomatic patients (AUC range 0.53-0.61).
Conclusion: This study found RPG in 29% of patients, most of them asymptomatic. However, a dorso-palmar cyst diameter > 3 mm may be clinically significant.
Clinical relevance statement: Radiopalmar ganglion cysts, observed in 29% of wrist MR examinations, are mostly asymptomatic, but those with a larger dorso-palmar diameter may be associated with radiopalmar complaints.
Key points: Radiopalmar ganglion cysts are found in 29% of patients undergoing wrist MRI. Most patients with evidence of radiopalmar ganglion cysts do not show radiopalmar symptoms (85%). A dorso-palmar cyst diameter > 3 mm may be associated with radiopalmar complaints.
期刊介绍:
European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field.
This is the Journal of the European Society of Radiology, and the official journal of a number of societies.
From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.