Effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength of composite to ceramic.

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2024-06-01 Epub Date: 2024-06-25 DOI:10.4047/jap.2024.16.3.163
Armaghan Naghili, Amirparsa Ghasemi, Amir Ghasemi, Narges Panahandeh
{"title":"Effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength of composite to ceramic.","authors":"Armaghan Naghili, Amirparsa Ghasemi, Amir Ghasemi, Narges Panahandeh","doi":"10.4047/jap.2024.16.3.163","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study assessed the effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength (µSBS) of composite to ceramic.</p><p><strong>Materials and methods: </strong>This study was conducted on 60 sintered zirconia and 60 feldspathic porcelain blocks. Half of the specimens (n = 30) were subjected to surface treatment with the single-bottle Clearfil ceramic primer (n = 15) and two-bottle experimental primer (n = 15) after 24 hours. The remaining half received the same surface treatments after 6 months storage in distilled water. Composite cylinders were bonded to the ceramics, and they were then subjected to µSBS test. Also, the primers underwent Fourier-transform infrared spectroscopy (FTIR) after 24 hours and 6 months to assess their chemical structure. Data were analyzed with 3-way ANOVA and adjusted Bonferroni test (alpha = 0.05).</p><p><strong>Results: </strong>The µSBS of both ceramics significantly decreased at 6 months in one-bottle ceramic primer group (<i>P</i> = .001), but it was not significantly different from the two-bottle experimental primer group (<i>P</i> = .635). FTIR showed hydrolysis of single-bottle primer, cleavage of silane and 10-MDP bonds, and formation of siloxane bonds after 6 months.</p><p><strong>Conclusion: </strong>Six months of storage caused significant degradation of single-bottle ceramic primer, and consequently had an adverse effect on µSBS.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 3","pages":"163-173"},"PeriodicalIF":2.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11215035/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2024.16.3.163","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study assessed the effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength (µSBS) of composite to ceramic.

Materials and methods: This study was conducted on 60 sintered zirconia and 60 feldspathic porcelain blocks. Half of the specimens (n = 30) were subjected to surface treatment with the single-bottle Clearfil ceramic primer (n = 15) and two-bottle experimental primer (n = 15) after 24 hours. The remaining half received the same surface treatments after 6 months storage in distilled water. Composite cylinders were bonded to the ceramics, and they were then subjected to µSBS test. Also, the primers underwent Fourier-transform infrared spectroscopy (FTIR) after 24 hours and 6 months to assess their chemical structure. Data were analyzed with 3-way ANOVA and adjusted Bonferroni test (alpha = 0.05).

Results: The µSBS of both ceramics significantly decreased at 6 months in one-bottle ceramic primer group (P = .001), but it was not significantly different from the two-bottle experimental primer group (P = .635). FTIR showed hydrolysis of single-bottle primer, cleavage of silane and 10-MDP bonds, and formation of siloxane bonds after 6 months.

Conclusion: Six months of storage caused significant degradation of single-bottle ceramic primer, and consequently had an adverse effect on µSBS.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
储存时间对单瓶和双瓶实验性陶瓷底漆化学结构以及复合材料与陶瓷微剪切粘接强度的影响。
目的:本研究评估了储存时间对单瓶和双瓶实验性陶瓷底漆的化学结构以及复合材料与陶瓷的微剪切粘接强度(µSBS)的影响:这项研究是在 60 个烧结氧化锆和 60 个长石瓷块上进行的。一半试样(n = 30)在 24 小时后用单瓶 Clearfil 陶瓷底漆(n = 15)和双瓶实验底漆(n = 15)进行表面处理。其余一半在蒸馏水中存放 6 个月后接受相同的表面处理。将复合材料圆柱体粘合到陶瓷上,然后对它们进行 µSBS 测试。此外,在 24 小时和 6 个月后,还对引物进行了傅立叶变换红外光谱(FTIR)分析,以评估其化学结构。数据分析采用 3 方方差分析和调整的 Bonferroni 检验(α = 0.05):结果:6 个月后,单瓶陶瓷底漆组两种陶瓷的 µSBS 都明显下降(P = .001),但与双瓶实验底漆组相比无明显差异(P = .635)。傅立叶变换红外光谱显示,6 个月后,单瓶底漆发生水解,硅烷和 10-MDP 键断裂,硅氧烷键形成:结论:6 个月的储存会导致单瓶陶瓷底漆发生明显降解,从而对 µSBS 产生不利影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A study to evaluate the influence of non-axial forces on tooth - a split mouth cross-sectional study. Comparison of osseointegration in commercial SLA-treated dental implants with different surface roughness: a pilot study in beagle dogs. Effect of scan path on accuracy of complete arch intraoral scan. Erratum - Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches. Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an in-vitro study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1