{"title":"PVDF transducer shape optimization for the characterization of anisotropic materials","authors":"Diego Cowes, Ignacio Mieza, Martín Gómez","doi":"arxiv-2406.12749","DOIUrl":null,"url":null,"abstract":"In the context of the ultrasonic determination of mechanical properties, it\nis common to use oblique incident waves to characterize fluid-immersed\nanisotropic samples. The lateral displacement of the ultrasonic field owing to\nleaky guided wave phenomena poses a challenge for data inversion because beam\nspreading is rarely well represented by plane-wave models. In this study, a\nfinite beam model based on the angular spectrum method was developed to\nestimate the influence of the transducer shape and position on the transmitted\nsignals. Additionally, anisotropic solids were considered so that the beam\nskewing effect was contemplated. A small-emitter large-receiver configuration\nwas chosen, and the ideal shape and position of the receiving transducer were\nobtained through a meta-heuristic optimization approach with the goal of\nachieving a measurement system that sufficiently resembles plane-wave\npropagation. A polyvinylidene fluoride receiver was fabricated and tested in\nthree cases: a single-crystal silicon wafer, a lightly anisotropic\nstainless-steel plate, and a highly anisotropic composite plate. Good agreement\nwas found between the measurements and the plane-wave model.","PeriodicalId":501482,"journal":{"name":"arXiv - PHYS - Classical Physics","volume":"176 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Classical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2406.12749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In the context of the ultrasonic determination of mechanical properties, it
is common to use oblique incident waves to characterize fluid-immersed
anisotropic samples. The lateral displacement of the ultrasonic field owing to
leaky guided wave phenomena poses a challenge for data inversion because beam
spreading is rarely well represented by plane-wave models. In this study, a
finite beam model based on the angular spectrum method was developed to
estimate the influence of the transducer shape and position on the transmitted
signals. Additionally, anisotropic solids were considered so that the beam
skewing effect was contemplated. A small-emitter large-receiver configuration
was chosen, and the ideal shape and position of the receiving transducer were
obtained through a meta-heuristic optimization approach with the goal of
achieving a measurement system that sufficiently resembles plane-wave
propagation. A polyvinylidene fluoride receiver was fabricated and tested in
three cases: a single-crystal silicon wafer, a lightly anisotropic
stainless-steel plate, and a highly anisotropic composite plate. Good agreement
was found between the measurements and the plane-wave model.