Contrast enhanced digital mammography as a predictor of breast cancer in patient with pathological nipple discharge

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Egyptian Journal of Radiology and Nuclear Medicine Pub Date : 2024-06-28 DOI:10.1186/s43055-024-01296-x
Lamiaa M. R. Khalaf, Mostafa A. M. El-Sharkawy, Mohamed Zedan, Khaled Rezk, Marwa Mosaed, Hosam M. Kamel
{"title":"Contrast enhanced digital mammography as a predictor of breast cancer in patient with pathological nipple discharge","authors":"Lamiaa M. R. Khalaf, Mostafa A. M. El-Sharkawy, Mohamed Zedan, Khaled Rezk, Marwa Mosaed, Hosam M. Kamel","doi":"10.1186/s43055-024-01296-x","DOIUrl":null,"url":null,"abstract":"Pathological nipple discharge (PND) commonly caused by benign diseases, but occasionally it signifies a major medical concern. Ultrasonography, in addition to mammography, is regarded as the standard imaging modality in the diagnosis of PND but their sensitivity in some cases are low, subsequently we used a contrast enhanced mammography (CEDM) as supplementary diagnostic modality in patients with PND. The purpose of our study was to investigate the diagnostic efficacy of CEDM in evaluating PND patients, added values of incorporating the CEDM in the diagnostic workup of patients with PND and to demonstrate its diagnostic significance as a predictor of malignancy in these patients as there have been few studies that have addressed the role of CEDM in the evaluation of PND. Forty seven patients with PND were enrolled in this prospective study and underwent CEDM. The CEDM had high specificity (83.2%) compared to the combined sonomammography (SM) (59.3%), as there was a decrease in the number of false positive cases detected by the CEDM (6 cases) compared to the combined SM (11 cases). Combined (SM) had a moderate degree of agreement (55%, P = 0.01) with the final diagnosis, whereas CEDM had a strong degree of agreement (75%, P < 0.001). Additionally, the combined SM reported 76.6% accuracy with an area under the curve of 0.8, whereas the CEDM had 87.2% accuracy with an area under the curve of 0.89. CEDM had higher specificity, positive predictive value, and accuracy than SM in PND patients, along with its stronger agreement with the final pathology results, subsequently reduce the rate of false positive cases and the rate of recall back, making it a highly accurate malignancy predictor in those patients and can be an invaluable diagnostic imaging tool for identifying associated malignancies.","PeriodicalId":11540,"journal":{"name":"Egyptian Journal of Radiology and Nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Radiology and Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43055-024-01296-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Pathological nipple discharge (PND) commonly caused by benign diseases, but occasionally it signifies a major medical concern. Ultrasonography, in addition to mammography, is regarded as the standard imaging modality in the diagnosis of PND but their sensitivity in some cases are low, subsequently we used a contrast enhanced mammography (CEDM) as supplementary diagnostic modality in patients with PND. The purpose of our study was to investigate the diagnostic efficacy of CEDM in evaluating PND patients, added values of incorporating the CEDM in the diagnostic workup of patients with PND and to demonstrate its diagnostic significance as a predictor of malignancy in these patients as there have been few studies that have addressed the role of CEDM in the evaluation of PND. Forty seven patients with PND were enrolled in this prospective study and underwent CEDM. The CEDM had high specificity (83.2%) compared to the combined sonomammography (SM) (59.3%), as there was a decrease in the number of false positive cases detected by the CEDM (6 cases) compared to the combined SM (11 cases). Combined (SM) had a moderate degree of agreement (55%, P = 0.01) with the final diagnosis, whereas CEDM had a strong degree of agreement (75%, P < 0.001). Additionally, the combined SM reported 76.6% accuracy with an area under the curve of 0.8, whereas the CEDM had 87.2% accuracy with an area under the curve of 0.89. CEDM had higher specificity, positive predictive value, and accuracy than SM in PND patients, along with its stronger agreement with the final pathology results, subsequently reduce the rate of false positive cases and the rate of recall back, making it a highly accurate malignancy predictor in those patients and can be an invaluable diagnostic imaging tool for identifying associated malignancies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对比度增强型数字乳腺 X 射线照相术作为病理性乳头溢液患者乳腺癌的预测指标
病理性乳头溢液(PND)通常由良性疾病引起,但偶尔也会引发重大的医学问题。除了乳房 X 光检查外,超声波检查也被认为是诊断 PND 的标准成像方式,但在某些病例中,超声波检查的灵敏度较低,因此我们使用对比增强乳房 X 光检查(CEDM)作为 PND 患者的辅助诊断方式。我们的研究旨在探讨对比增强乳腺 X 线造影在评估 PND 患者中的诊断效果、将对比增强乳腺 X 线造影纳入 PND 患者诊断工作中的附加价值,并证明对比增强乳腺 X 线造影作为这些患者恶性肿瘤预测指标的诊断意义,因为目前很少有研究探讨对比增强乳腺 X 线造影在评估 PND 中的作用。在这项前瞻性研究中,47 名 PND 患者接受了 CEDM 检查。CEDM 的特异性(83.2%)高于联合超声造影(59.3%),因为 CEDM 检测出的假阳性病例(6 例)少于联合超声造影(11 例)。联合(SM)与最终诊断的吻合程度为中等(55%,P = 0.01),而 CEDM 的吻合程度很高(75%,P < 0.001)。此外,联合 SM 的准确率为 76.6%,曲线下面积为 0.8,而 CEDM 的准确率为 87.2%,曲线下面积为 0.89。在PND患者中,CEDM比SM具有更高的特异性、阳性预测值和准确性,而且它与最终病理结果的一致性更强,从而降低了假阳性病例率和回访率,使其成为这些患者中高度准确的恶性肿瘤预测指标,并可成为鉴别相关恶性肿瘤的宝贵影像诊断工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Egyptian Journal of Radiology and Nuclear Medicine
Egyptian Journal of Radiology and Nuclear Medicine Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.70
自引率
10.00%
发文量
233
审稿时长
27 weeks
期刊最新文献
Fetal hemochromatosis: rare case of hepatic and extrahepatic siderosis involving thyroid on fetal MRI Ultrasound-guided combined intra-articular corticosteroids injection and suprascapular nerve block for pain control in patients with frozen shoulder Pharmacomechanical thrombectomy in management of pulmonary embolism Role of intravoxel incoherent motion diffusion-weighted MRI in differentiation of renal cell carcinoma subtypes Explainability, transparency and black box challenges of AI in radiology: impact on patient care in cardiovascular radiology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1