E. Bouquerel, T. Adama, C. Maazouzi, E. Traykov, P. Graehling, C. Mathieu
{"title":"LEEx-B: Low Energy Experimental Bench Development at IPHC-CNRS Strasbourg","authors":"E. Bouquerel, T. Adama, C. Maazouzi, E. Traykov, P. Graehling, C. Mathieu","doi":"arxiv-2407.02107","DOIUrl":null,"url":null,"abstract":"As a part of future developments of beam diagnostics, a low energy\nexperimental bench (LEEx-B) has been recently designed, built and commissioned\nat IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on\na HV platform and providing beams up to 25 keV. A beam profiler and an\nAllison-type emittance-meter allow the qualification of the setup and also the\ncharacterization of the beam. During the commissioning process, the\nelectronics, and the control system were upgraded in order to push the limits\ntowards low beam currents measured by the emittance-meter.","PeriodicalId":501318,"journal":{"name":"arXiv - PHYS - Accelerator Physics","volume":"59 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Accelerator Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2407.02107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
As a part of future developments of beam diagnostics, a low energy
experimental bench (LEEx-B) has been recently designed, built and commissioned
at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on
a HV platform and providing beams up to 25 keV. A beam profiler and an
Allison-type emittance-meter allow the qualification of the setup and also the
characterization of the beam. During the commissioning process, the
electronics, and the control system were upgraded in order to push the limits
towards low beam currents measured by the emittance-meter.