Gamze Ergin Kizilçay, Sena Çağlar Andaç, Sıdıka Ertürk Toker
{"title":"Fast Determination of Fat-soluble Vitamins in Pharmaceutical Preparations by High-Performance Liquid Chromatography","authors":"Gamze Ergin Kizilçay, Sena Çağlar Andaç, Sıdıka Ertürk Toker","doi":"10.2174/0115734110314921240622111849","DOIUrl":null,"url":null,"abstract":"Background: Vitamins are needed for the healthy functioning of the body. When these vitamins are not in sufficient amounts in the body, they are usually taken externally with pharmaceutical preparations. Taking vitamins into the body in the right amounts is possible by analyzing the amounts in pharmaceutical preparations with validated methods. Methods: In this study, a fast, simple, easily applicable, and selective normal-phase HPLC method was developed for the simultaneous determination of fat-soluble A, D3, E, and K1 vitamins in pharmaceutical preparations from syrup and tablets. Separation of the vitamins was carried out on a Zorbax CN column (250 x 4.6 mm, 5 µm) using a mixture of hexane-isopropyl alcohol (98:2, v/v) at 30°C column temperature and 1 ml/min flow rate. The detection wavelength is 280 nm. The developed method has been validated according to ICH Harmonised Tripartite Guideline Validation of Analytical Procedures: Text and Methodology Q2(R1) rules. Results: Calibration graphs are linear over the range of 10-1000 µg ml-1 , 1-50 µg ml-1 , 10-2000 µg ml-1 , 0.5-20 µg ml-1, and the limit of detection values were found to be 1.496, 0.280, 1.388 and 0.040 µg ml-1 for A, D3, E and K1 vitamins, respectively. Relative standard deviation values, which express within-day and between-day repeatability, were found below 2.54%. Average recovery values were also found at about 100.28, 101.46, 100.65, and 100.29% for A, D3, E, and K1 vitamins, respectively Conclusion: The developed and validated method was successfully applied to the simultaneous analysis of fat-soluble vitamins A, D3, E, and K1 in pharmaceutical preparations in syrup and tablet form.","PeriodicalId":10742,"journal":{"name":"Current Analytical Chemistry","volume":"4 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.2174/0115734110314921240622111849","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Vitamins are needed for the healthy functioning of the body. When these vitamins are not in sufficient amounts in the body, they are usually taken externally with pharmaceutical preparations. Taking vitamins into the body in the right amounts is possible by analyzing the amounts in pharmaceutical preparations with validated methods. Methods: In this study, a fast, simple, easily applicable, and selective normal-phase HPLC method was developed for the simultaneous determination of fat-soluble A, D3, E, and K1 vitamins in pharmaceutical preparations from syrup and tablets. Separation of the vitamins was carried out on a Zorbax CN column (250 x 4.6 mm, 5 µm) using a mixture of hexane-isopropyl alcohol (98:2, v/v) at 30°C column temperature and 1 ml/min flow rate. The detection wavelength is 280 nm. The developed method has been validated according to ICH Harmonised Tripartite Guideline Validation of Analytical Procedures: Text and Methodology Q2(R1) rules. Results: Calibration graphs are linear over the range of 10-1000 µg ml-1 , 1-50 µg ml-1 , 10-2000 µg ml-1 , 0.5-20 µg ml-1, and the limit of detection values were found to be 1.496, 0.280, 1.388 and 0.040 µg ml-1 for A, D3, E and K1 vitamins, respectively. Relative standard deviation values, which express within-day and between-day repeatability, were found below 2.54%. Average recovery values were also found at about 100.28, 101.46, 100.65, and 100.29% for A, D3, E, and K1 vitamins, respectively Conclusion: The developed and validated method was successfully applied to the simultaneous analysis of fat-soluble vitamins A, D3, E, and K1 in pharmaceutical preparations in syrup and tablet form.
期刊介绍:
Current Analytical Chemistry publishes full-length/mini reviews and original research articles on the most recent advances in analytical chemistry. All aspects of the field are represented, including analytical methodology, techniques, and instrumentation in both fundamental and applied research topics of interest to the broad readership of the journal. Current Analytical Chemistry strives to serve as an authoritative source of information in analytical chemistry and in related applications such as biochemical analysis, pharmaceutical research, quantitative biological imaging, novel sensors, and nanotechnology.