Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and its Application in the Postoperative Fitting Process.

IF 1.2 4区 综合性期刊 Q3 MULTIDISCIPLINARY SCIENCES Jove-Journal of Visualized Experiments Pub Date : 2024-06-21 DOI:10.3791/66526
Maria Magdalena Mair, Ruth Schröcksnadel, Kurt Stephan, Josef Seebacher, Philipp Zelger, Franz Muigg, Timo Gottfried, Annett Franke-Trieger, Joachim Schmutzhard
{"title":"Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and its Application in the Postoperative Fitting Process.","authors":"Maria Magdalena Mair, Ruth Schröcksnadel, Kurt Stephan, Josef Seebacher, Philipp Zelger, Franz Muigg, Timo Gottfried, Annett Franke-Trieger, Joachim Schmutzhard","doi":"10.3791/66526","DOIUrl":null,"url":null,"abstract":"<p><p>Measuring the electrically evoked stapedius reflex during the fitting of cochlear implants (CIs) provides a reliable estimation of maximum comfort levels, resulting in the programming of the CI with high hearing comfort and good speech understanding. Detection of the stapedius reflex and the required stimulation level on each implant channel is already being performed during surgery, whereby intraoperative stapedius reflexes are observed through the surgical microscope. Intraoperative stapedius reflex detection is both an indicator that the auditory nerve is responding to electrical stimulation up to the brainstem and a test for the ability to perform postoperative stapedius reflex measurements. Postoperative stapedius reflex thresholds can be used to estimate upper stimulation levels in the CI fitting process. In particular, in children or patients unable to provide feedback on loudness perception, this method avoids inadequate stimulation with the CI, which can result in poor hearing performance. In addition, overstimulation can be avoided, which could even lead to refusal to use the device.</p>","PeriodicalId":48787,"journal":{"name":"Jove-Journal of Visualized Experiments","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jove-Journal of Visualized Experiments","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3791/66526","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Measuring the electrically evoked stapedius reflex during the fitting of cochlear implants (CIs) provides a reliable estimation of maximum comfort levels, resulting in the programming of the CI with high hearing comfort and good speech understanding. Detection of the stapedius reflex and the required stimulation level on each implant channel is already being performed during surgery, whereby intraoperative stapedius reflexes are observed through the surgical microscope. Intraoperative stapedius reflex detection is both an indicator that the auditory nerve is responding to electrical stimulation up to the brainstem and a test for the ability to perform postoperative stapedius reflex measurements. Postoperative stapedius reflex thresholds can be used to estimate upper stimulation levels in the CI fitting process. In particular, in children or patients unable to provide feedback on loudness perception, this method avoids inadequate stimulation with the CI, which can result in poor hearing performance. In addition, overstimulation can be avoided, which could even lead to refusal to use the device.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工耳蜗植入术中的镫骨反射电诱发测量及其在术后装配过程中的应用。
在安装人工耳蜗(CI)时,通过测量电诱发的镫骨反射,可以可靠地估计最大舒适度,从而使人工耳蜗的编程具有较高的听力舒适度和良好的言语理解能力。在手术过程中,通过手术显微镜观察术中镫骨反射,并确定每个植入通道所需的刺激水平。术中镫骨反射检测既是听神经对直至脑干的电刺激做出反应的指标,也是对术后镫骨反射测量能力的测试。术后镫骨反射阈值可用于估计 CI 装配过程中的上限刺激水平。特别是对于无法提供响度感知反馈的儿童或患者,这种方法可以避免 CI 刺激不足,从而导致听力表现不佳。此外,还可以避免过度刺激,因为过度刺激甚至会导致患者拒绝使用设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Jove-Journal of Visualized Experiments
Jove-Journal of Visualized Experiments MULTIDISCIPLINARY SCIENCES-
CiteScore
2.10
自引率
0.00%
发文量
992
期刊介绍: JoVE, the Journal of Visualized Experiments, is the world''s first peer reviewed scientific video journal. Established in 2006, JoVE is devoted to publishing scientific research in a visual format to help researchers overcome two of the biggest challenges facing the scientific research community today; poor reproducibility and the time and labor intensive nature of learning new experimental techniques.
期刊最新文献
A Rapid Method to Confine and Safely Handle Bees in the Field. Characterizing Mediated Extracellular Electron Transfer in Lactic Acid Bacteria with a Three-Electrode, Two-Chamber Bioelectrochemical System. Consistent Delivery of Adeno-Associated Virus via Lateral Tail-Vein Injection in Adult Mice. Detection of DNA Breaks in Dividing Human Cells by Neutral Comet Assay. Effective Detection of Hoechst Side Population Cells by Flow Cytometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1