Effect of a 3-second Off-label Exposure on the Depth of Cure of Eight Resin-based Composites.

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Operative dentistry Pub Date : 2024-07-01 DOI:10.2341/23-155-L
Mth Ribeiro, C Maucoski, R B Price, C J Soares
{"title":"Effect of a 3-second Off-label Exposure on the Depth of Cure of Eight Resin-based Composites.","authors":"Mth Ribeiro, C Maucoski, R B Price, C J Soares","doi":"10.2341/23-155-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds.</p><p><strong>Methods: </strong>Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be photocured in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (α=0.05).</p><p><strong>Results: </strong>There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) when photocured off-label using the 3-second high irradiance mode.</p><p><strong>Conclusion: </strong>Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"421-431"},"PeriodicalIF":1.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-155-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds.

Methods: Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be photocured in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (α=0.05).

Results: There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) when photocured off-label using the 3-second high irradiance mode.

Conclusion: Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3 秒标签外曝光对八种树脂基复合材料固化深度的影响
目标:本研究评估了八种树脂基复合材料(RBC)的固化深度(DoC),光固化时使用一个多峰值光固化装置(LCU),在制造商推荐的 RBC 曝光时间内使用标准输出设置,并在较高的辐照度下照射 3 秒钟:方法:三种传统 RBC:方法:三种传统 RBC:Tetric EvoCeram (Evo)、Tetric N-Ceram (Cer)、Tetric Prime (Pri);五种散装填充:Tetric N-Ceram Bulk Fill (CerBF)、Opus Bulk Fill APS (OpusBF)、Opus Bulk Fill Flow APS (OpusF)、Tetric PowerFill (PFill) 和 Tetric PowerFlow (PFlow)。只有 PFill 和 PFlow 可在 3 秒钟内完成光固化。将 RBC 装入金属模具中,使用 Bluephase PowerCure LCU 按照 RBC 制造商建议的曝光时间,在标准模式和 3 秒高辐照度模式下进行光固化。光固化后,将试样浸入溶剂中 1 小时。数据分析采用双向方差分析(ANOVA),然后进行 Tukey 后多重比较检验(α=0.05):使用 3 秒高辐照度方案进行光固化时,PFill 和 PFlow 的 DoC 值与低辐照度标准模式方案相比没有明显差异。所有其他 RBC 的 DoC 值都明显较低(p 结论:在测试的八种 RBC 中,只有 PFill 和 PFlow 在使用 3 秒钟高辐照度固化方法时,其 DoC 值与使用较长的低辐照度固化方法时相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
期刊最新文献
3D Printed Dual Reduction Guide: A Feasible Alternative for Conservative Gingivectomy and Minimally Invasive Preparation for Ceramic Veneers. A Novel Isolation Technique Using Polytetrafluoroethylene Tape and Split Dam Isolation for Cementation in Bridge Restorations. Bacterial Adhesion and In Situ Biodegradation of Preheated Resin Composite Used as a Luting Agent for Indirect Restorations. Biomechanical and Physical Characteristics of Dental Dam Sheets Used for Absolute Isolation. Bonding and Cleaning Effects of Irrigation Protocols Using Calcium Hypochlorite on the Post-space Radicular Dentin.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1