Radiomics model based on dual-energy CT can determine the source of thrombus in strokes with middle cerebral artery occlusion.

IF 2.4 3区 医学 Q2 CLINICAL NEUROLOGY Neuroradiology Pub Date : 2024-10-01 Epub Date: 2024-07-10 DOI:10.1007/s00234-024-03422-y
Yuzhu Ma, Yao Dai, Ying Zhao, Ziyang Song, Chunhong Hu, Yu Zhang
{"title":"Radiomics model based on dual-energy CT can determine the source of thrombus in strokes with middle cerebral artery occlusion.","authors":"Yuzhu Ma, Yao Dai, Ying Zhao, Ziyang Song, Chunhong Hu, Yu Zhang","doi":"10.1007/s00234-024-03422-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop thrombus radiomics models based on dual-energy CT (DECT) for predicting etiologic cause of stroke.</p><p><strong>Methods: </strong>We retrospectively enrolled patients with occlusion of the middle cerebral artery who underwent computed tomography (NCCT) and DECT angiography (DECTA). 70 keV virtual monoenergetic images (simulate conventional 120kVp CTA images) and iodine overlay maps (IOM) were reconstructed for analysis. Five logistic regression radiomics models for predicting cardioembolism (CE) were built based on the features extracted from NCCT, CTA and IOM images. From these, the best one was selected to integrate with clinical information for further construction of the combined model. The performance of the different models was evaluated and compared using ROC curve analysis, clinical decision curves (DCA), calibration curves and Delong test.</p><p><strong>Results: </strong>Among all the radiomic models, model <sub>NCCT+IOM</sub> performed the best, with AUC = 0.95 significantly higher than model <sub>NCCT,</sub> model <sub>CTA</sub>, model <sub>IOM</sub> and model <sub>NCCT+CTA</sub> in the training set (AUC = 0.88, 0.78, 0.90,0.87, respectively, P < 0.05), and AUC = 0.92 in the testing set, significantly higher than model <sub>CTA</sub> (AUC = 0.71, P < 0.05). Smoking and NIHSS score were independent predictors of CE (P < 0.05). The combined model performed similarly to the model <sub>NCCT+IOM</sub>, with no statistically significant difference in AUC either in the training or test sets. (0.96 vs. 0.95; 0.94 vs. 0.92, both P > 0.05).</p><p><strong>Conclusion: </strong>Radiomics models constructed based on NCCT and IOM images can effectively determine the source of thrombus in stroke without relying on clinical information.</p>","PeriodicalId":19422,"journal":{"name":"Neuroradiology","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-024-03422-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop thrombus radiomics models based on dual-energy CT (DECT) for predicting etiologic cause of stroke.

Methods: We retrospectively enrolled patients with occlusion of the middle cerebral artery who underwent computed tomography (NCCT) and DECT angiography (DECTA). 70 keV virtual monoenergetic images (simulate conventional 120kVp CTA images) and iodine overlay maps (IOM) were reconstructed for analysis. Five logistic regression radiomics models for predicting cardioembolism (CE) were built based on the features extracted from NCCT, CTA and IOM images. From these, the best one was selected to integrate with clinical information for further construction of the combined model. The performance of the different models was evaluated and compared using ROC curve analysis, clinical decision curves (DCA), calibration curves and Delong test.

Results: Among all the radiomic models, model NCCT+IOM performed the best, with AUC = 0.95 significantly higher than model NCCT, model CTA, model IOM and model NCCT+CTA in the training set (AUC = 0.88, 0.78, 0.90,0.87, respectively, P < 0.05), and AUC = 0.92 in the testing set, significantly higher than model CTA (AUC = 0.71, P < 0.05). Smoking and NIHSS score were independent predictors of CE (P < 0.05). The combined model performed similarly to the model NCCT+IOM, with no statistically significant difference in AUC either in the training or test sets. (0.96 vs. 0.95; 0.94 vs. 0.92, both P > 0.05).

Conclusion: Radiomics models constructed based on NCCT and IOM images can effectively determine the source of thrombus in stroke without relying on clinical information.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于双能 CT 的放射组学模型可确定大脑中动脉闭塞性脑卒中的血栓来源。
目的:开发基于双能 CT(DECT)的血栓放射组学模型,用于预测脑卒中的病因:我们回顾性研究了接受计算机断层扫描(NCCT)和 DECT 血管造影(DECTA)的大脑中动脉闭塞患者。对 70 keV 虚拟单能图像(模拟常规 120kVp CTA 图像)和碘覆盖图 (IOM) 进行了重建分析。根据从 NCCT、CTA 和 IOM 图像中提取的特征,建立了五个用于预测心肌栓塞(CE)的逻辑回归放射组学模型。从中选出最佳模型与临床信息相结合,进一步构建综合模型。使用 ROC 曲线分析、临床决策曲线(DCA)、校准曲线和 Delong 检验对不同模型的性能进行了评估和比较:在所有放射学模型中,NCCT+IOM 模型表现最佳,其 AUC = 0.95 明显高于训练集中的 NCCT、CTA、IOM 和 NCCT+CTA 模型(AUC 分别为 0.88、0.78、0.90、0.87,P CTA(AUC = 0.71,P NCCT+IOM,无论是训练集还是测试集,AUC 均无显著统计学差异。(结论:结论:基于 NCCT 和 IOM 图像构建的放射组学模型可有效确定脑卒中血栓的来源,而无需依赖临床信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Neuroradiology
Neuroradiology 医学-核医学
CiteScore
5.30
自引率
3.60%
发文量
214
审稿时长
4-8 weeks
期刊介绍: Neuroradiology aims to provide state-of-the-art medical and scientific information in the fields of Neuroradiology, Neurosciences, Neurology, Psychiatry, Neurosurgery, and related medical specialities. Neuroradiology as the official Journal of the European Society of Neuroradiology receives submissions from all parts of the world and publishes peer-reviewed original research, comprehensive reviews, educational papers, opinion papers, and short reports on exceptional clinical observations and new technical developments in the field of Neuroimaging and Neurointervention. The journal has subsections for Diagnostic and Interventional Neuroradiology, Advanced Neuroimaging, Paediatric Neuroradiology, Head-Neck-ENT Radiology, Spine Neuroradiology, and for submissions from Japan. Neuroradiology aims to provide new knowledge about and insights into the function and pathology of the human nervous system that may help to better diagnose and treat nervous system diseases. Neuroradiology is a member of the Committee on Publication Ethics (COPE) and follows the COPE core practices. Neuroradiology prefers articles that are free of bias, self-critical regarding limitations, transparent and clear in describing study participants, methods, and statistics, and short in presenting results. Before peer-review all submissions are automatically checked by iThenticate to assess for potential overlap in prior publication.
期刊最新文献
Machine learning based classification of spontaneous intracranial hemorrhages using radiomics features. Pineal gland ADC values in children aged 0 to 4 years: normative data and usefulness in the differential diagnosis with trilateral retinoblastoma. MR-Neurography of the facial nerve in parotid tumors: intra-parotid nerve visualization and surgical correlation. A Comparative Study of AI-Based Automated and Manual Postprocessing of Head and Neck CT Angiography: An Independent External Validation with Multi-Vendor and Multi-Center Data. CT-guided radiofrequency ablation of facial and mandibular nerves in the treatment of compound Meige's syndrome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1