Daniel Hameed, Bryan D Springer, Arthur L Malkani, Michael A Mont
{"title":"The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series.","authors":"Daniel Hameed, Bryan D Springer, Arthur L Malkani, Michael A Mont","doi":"10.52198/24.STI.44.OS1799","DOIUrl":null,"url":null,"abstract":"<p><p>Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/24.STI.44.OS1799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.