{"title":"High-resolution and highly accelerated MRI T2 mapping as a tool to characterise renal tumour subtypes and grades.","authors":"Ines Horvat-Menih, Hao Li, Andrew N Priest, Shaohang Li, Andrew B Gill, Iosif A Mendichovszky, Susan T Francis, Anne Y Warren, Brent O'Carrigan, Sarah J Welsh, James O Jones, Antony C P Riddick, James N Armitage, Thomas J Mitchell, Grant D Stewart, Ferdia A Gallagher","doi":"10.1186/s41747-024-00476-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Clinical imaging tools to probe aggressiveness of renal masses are lacking, and T2-weighted imaging as an integral part of magnetic resonance imaging protocol only provides qualitative information. We developed high-resolution and accelerated T2 mapping methods based on echo merging and using k-t undersampling and reduced flip angles (TEMPURA) and tested their potential to quantify differences between renal tumour subtypes and grades.</p><p><strong>Methods: </strong>Twenty-four patients with treatment-naïve renal tumours were imaged: seven renal oncocytomas (RO); one eosinophilic/oncocytic renal cell carcinoma; two chromophobe RCCs (chRCC); three papillary RCCs (pRCC); and twelve clear cell RCCs (ccRCC). Median, kurtosis, and skewness of T2 were quantified in tumours and in the normal-adjacent kidney cortex and were compared across renal tumour subtypes and between ccRCC grades.</p><p><strong>Results: </strong>High-resolution TEMPURA depicted the tumour structure at improved resolution compared to conventional T2-weighted imaging. The lowest median T2 values were present in pRCC (high-resolution, 51 ms; accelerated, 45 ms), which was significantly lower than RO (high-resolution; accelerated, p = 0.012) and ccRCC (high-resolution, p = 0.019; accelerated, p = 0.008). ROs showed the lowest kurtosis (high-resolution, 3.4; accelerated, 4.0), suggestive of low intratumoural heterogeneity. Lower T2 values were observed in higher compared to lower grade ccRCCs (grades 2, 3 and 4 on high-resolution, 209 ms, 151 ms, and 106 ms; on accelerated, 172 ms, 160 ms, and 102 ms, respectively), with accelerated TEMPURA showing statistical significance in comparison (p = 0.037).</p><p><strong>Conclusions: </strong>Both high-resolution and accelerated TEMPURA showed marked potential to quantify differences across renal tumour subtypes and between ccRCC grades.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov, NCT03741426 . Registered on 13 November 2018.</p><p><strong>Relevance statement: </strong>The newly developed T<sub>2</sub> mapping methods have improved resolution, shorter acquisition times, and promising quantifiable readouts to characterise incidental renal masses.</p>","PeriodicalId":36926,"journal":{"name":"European Radiology Experimental","volume":"8 1","pages":"76"},"PeriodicalIF":3.7000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11233479/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41747-024-00476-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Clinical imaging tools to probe aggressiveness of renal masses are lacking, and T2-weighted imaging as an integral part of magnetic resonance imaging protocol only provides qualitative information. We developed high-resolution and accelerated T2 mapping methods based on echo merging and using k-t undersampling and reduced flip angles (TEMPURA) and tested their potential to quantify differences between renal tumour subtypes and grades.

Methods: Twenty-four patients with treatment-naïve renal tumours were imaged: seven renal oncocytomas (RO); one eosinophilic/oncocytic renal cell carcinoma; two chromophobe RCCs (chRCC); three papillary RCCs (pRCC); and twelve clear cell RCCs (ccRCC). Median, kurtosis, and skewness of T2 were quantified in tumours and in the normal-adjacent kidney cortex and were compared across renal tumour subtypes and between ccRCC grades.

Results: High-resolution TEMPURA depicted the tumour structure at improved resolution compared to conventional T2-weighted imaging. The lowest median T2 values were present in pRCC (high-resolution, 51 ms; accelerated, 45 ms), which was significantly lower than RO (high-resolution; accelerated, p = 0.012) and ccRCC (high-resolution, p = 0.019; accelerated, p = 0.008). ROs showed the lowest kurtosis (high-resolution, 3.4; accelerated, 4.0), suggestive of low intratumoural heterogeneity. Lower T2 values were observed in higher compared to lower grade ccRCCs (grades 2, 3 and 4 on high-resolution, 209 ms, 151 ms, and 106 ms; on accelerated, 172 ms, 160 ms, and 102 ms, respectively), with accelerated TEMPURA showing statistical significance in comparison (p = 0.037).

Conclusions: Both high-resolution and accelerated TEMPURA showed marked potential to quantify differences across renal tumour subtypes and between ccRCC grades.

Trial registration: ClinicalTrials.gov, NCT03741426 . Registered on 13 November 2018.

Relevance statement: The newly developed T2 mapping methods have improved resolution, shorter acquisition times, and promising quantifiable readouts to characterise incidental renal masses.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高分辨率和高度加速的磁共振成像 T2 图是描述肾脏肿瘤亚型和分级的工具。
背景:目前还缺乏探查肾脏肿块侵袭性的临床成像工具,T2加权成像作为磁共振成像方案中不可或缺的一部分,只能提供定性信息。我们开发了基于回波合并、使用 k-t 欠采样和减小翻转角度(TEMPURA)的高分辨率加速 T2 映射方法,并测试了其量化肾脏肿瘤亚型和分级差异的潜力:对24例未接受过治疗的肾肿瘤患者进行了成像:7例肾肿瘤细胞瘤(RO)、1例嗜酸性/单核细胞肾细胞癌、2例嗜铬性RCC(chRCC)、3例乳头状RCC(pRCC)和12例透明细胞RCC(ccRCC)。对肿瘤和正常邻近肾皮质的 T2 中位数、峰度和偏度进行了量化,并对不同肾肿瘤亚型和不同级别的 ccRCC 进行了比较:与传统的 T2 加权成像相比,高分辨率 TEMPURA 能以更高的分辨率显示肿瘤结构。中位 T2 值最低的是 pRCC(高分辨率,51 毫秒;加速成像,45 毫秒),明显低于 RO(高分辨率;加速成像,p = 0.012)和 ccRCC(高分辨率,p = 0.019;加速成像,p = 0.008)。RO的峰度最低(高分辨率,3.4;加速度,4.0),表明瘤内异质性较低。与低级别ccRCC相比,高级别ccRCC的T2值更低(2、3和4级在高分辨率下分别为209毫秒、151毫秒和106毫秒;在加速TEMPURA下分别为172毫秒、160毫秒和102毫秒),加速TEMPURA与之相比具有统计学意义(p = 0.037):结论:高分辨率和加速 TEMPURA 在量化肾脏肿瘤亚型和 ccRCC 分级之间的差异方面都显示出明显的潜力:ClinicalTrials.gov, NCT03741426 .注册时间:2018年11月13日.相关性声明:新开发的T2映射方法具有更高的分辨率、更短的采集时间和有前景的可量化读数,可用于描述附带肾肿块的特征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Radiology Experimental
European Radiology Experimental Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
6.70
自引率
2.60%
发文量
56
审稿时长
18 weeks
期刊最新文献
An AI deep learning algorithm for detecting pulmonary nodules on ultra-low-dose CT in an emergency setting: a reader study. Evaluation of pulmonary artery pressure, blood indices, and myocardial microcirculation in rats returning from high altitude to moderate altitude. Image biomarkers and explainable AI: handcrafted features versus deep learned features. Technical feasibility of automated blur detection in digital mammography using convolutional neural network. Quantification of breast biopsy clip marker artifact on routine breast MRI sequences: a phantom study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1