Case report: Inferior valved for non-valved glaucoma drainage device exchange for glaucoma control and cosmesis.

Frontiers in ophthalmology Pub Date : 2024-05-31 eCollection Date: 2024-01-01 DOI:10.3389/fopht.2024.1361898
Abdullah M Khan, Maram E A Abdalla Elsayed, Rizwan Malik
{"title":"Case report: Inferior valved for non-valved glaucoma drainage device exchange for glaucoma control and cosmesis.","authors":"Abdullah M Khan, Maram E A Abdalla Elsayed, Rizwan Malik","doi":"10.3389/fopht.2024.1361898","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>While the exchange of a superior valved glaucoma drainage device (GDD) for a non-valved GDD has been reported for achieving glaucoma control, inferior GDD exchange for improving the cosmetic appearance of the eyes due to poor appearance caused by encapsulated GDDs has not been previously documented. Here, we report on two patients with inferior valved GDDs who underwent an exchange for non-valved devices for glaucoma control and cosmetic improvement.</p><p><strong>Case description: </strong>We report on the case of a 23-year-old gentleman and that of an 8-year-old girl, both of whom had inferior valved GDDs with uncontrolled intraocular pressure and unsightly appearance due to encapsulated GDD plates within the palpebral aperture. Both patients were unhappy about the appearance of their eyes. In each case, improvements in both glaucoma control and cosmesis were achieved by exchanging the valved GDDs for non-valved ones.</p><p><strong>Conclusion: </strong>Exchanging a valved for a non-valved GDD might help improve the cosmetic appearance of the eyes, in addition to providing glaucoma control.</p>","PeriodicalId":73096,"journal":{"name":"Frontiers in ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11182133/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fopht.2024.1361898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: While the exchange of a superior valved glaucoma drainage device (GDD) for a non-valved GDD has been reported for achieving glaucoma control, inferior GDD exchange for improving the cosmetic appearance of the eyes due to poor appearance caused by encapsulated GDDs has not been previously documented. Here, we report on two patients with inferior valved GDDs who underwent an exchange for non-valved devices for glaucoma control and cosmetic improvement.

Case description: We report on the case of a 23-year-old gentleman and that of an 8-year-old girl, both of whom had inferior valved GDDs with uncontrolled intraocular pressure and unsightly appearance due to encapsulated GDD plates within the palpebral aperture. Both patients were unhappy about the appearance of their eyes. In each case, improvements in both glaucoma control and cosmesis were achieved by exchanging the valved GDDs for non-valved ones.

Conclusion: Exchanging a valved for a non-valved GDD might help improve the cosmetic appearance of the eyes, in addition to providing glaucoma control.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
病例报告:下阀式青光眼引流装置与无阀式青光眼引流装置互换,以控制青光眼并改善外观。
导言:将上瓣膜青光眼引流装置(GDD)换成无瓣膜 GDD 以达到控制青光眼的目的已有报道,但将下瓣膜青光眼引流装置换成无瓣膜 GDD 以改善包膜 GDD 造成的外观不佳而导致的眼部外观不佳的情况还未见报道。在此,我们报告了两名患有下瓣膜 GDD 的患者,他们接受了无瓣膜装置的交换手术,从而控制了青光眼并改善了外观:我们报告了一名 23 岁男性和一名 8 岁女孩的病例,这两名患者都患有下瓣膜 GDD,眼压无法控制,而且由于 GDD 板被包裹在睑板孔内,外观难看。这两名患者都对自己的眼睛外观不满意。通过将带阀 GDD 换成无阀 GDD,两例患者的青光眼控制和外观都得到了改善:结论:将有瓣膜的 GDD 换成无瓣膜的,除了能控制青光眼外,还有助于改善眼睛的外观。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
期刊最新文献
Comparison of the PlusoptiX A16 and vision screener V100. UV light and the ocular lens: a review of exposure models and resulting biomolecular changes. Diagnostic accuracy of a modularized, virtual-reality-based automated pupillometer for detection of relative afferent pupillary defect in unilateral optic neuropathies. Advances in the management of intraocular foreign bodies. Large animal model species in pluripotent stem cell therapy research and development for retinal diseases: a systematic review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1