Clinical Applicability and Safety of Conventional Frame-Based Stereotactic Techniques for Stereoelectroencephalography.

IF 1.4 4区 医学 Q4 CLINICAL NEUROLOGY Journal of Korean Neurosurgical Society Pub Date : 2024-07-11 DOI:10.3340/jkns.2023.0246
Junhyung Kim, Seok Ho Hong, Hyun-Jin Kim, Mi-Sun Yum, Tae Sung Ko, Yong Seo Koo, Sang-Ahm Lee
{"title":"Clinical Applicability and Safety of Conventional Frame-Based Stereotactic Techniques for Stereoelectroencephalography.","authors":"Junhyung Kim, Seok Ho Hong, Hyun-Jin Kim, Mi-Sun Yum, Tae Sung Ko, Yong Seo Koo, Sang-Ahm Lee","doi":"10.3340/jkns.2023.0246","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Stereoelectroencephalography (SEEG) is increasingly being recognized as an important invasive modality for presurgical evaluation of epilepsy. This study focuses on the clinical and technical considerations of SEEG investigations when using conventional frame-based stereotaxy, drawing on institutional experience and a comprehensive review of relevant literature.</p><p><strong>Methods: </strong>This retrospective observational study encompassed the surgical implantation of 201 SEEG electrodes in 16 epilepsy patients using a frame-based stereotactic instrument at a single tertiary-level center. We provide detailed descriptions of the operative procedures and technical nuances for bilateral and multiple SEEG insertions, along with several illustrative cases. Additionally, we present a literature review on the technical aspects of the SEEG procedure, discussing its clinical implications and potential risks.</p><p><strong>Results: </strong>Frame-based SEEG electrode placements were successfully performed through sagittal arc application, with the majority (81.2%) of cases being bilateral and involving up to 18 electrodes in a single operation. The median skin-to-skin operation time was 162 minutes (interquartile range [IQR], 145-200), with a median of 13 minutes (IQR, 12-15) per electrode placement for time efficiency. There were two occurrences (1.0%) of electrode misplacement and one instance (0.5%) of a postoperative complication, which manifested as a delayed intraparenchymal hemorrhage. Following SEEG investigation, 11 patients proceeded with surgical intervention, resulting in favorable seizure outcomes for nine (81.8%) and complete remission for eight cases (72.7%).</p><p><strong>Conclusion: </strong>Conventional frame-based stereotactic techniques remain a reliable and effective option for bilateral and multiple SEEG electrode placements. While SEEG is a suitable approach for selected patients who are strong candidates for epilepsy surgery, it is important to remain vigilant concerning the potential risks of electrode misplacement and hemorrhagic complications.</p>","PeriodicalId":16283,"journal":{"name":"Journal of Korean Neurosurgical Society","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Korean Neurosurgical Society","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3340/jkns.2023.0246","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Stereoelectroencephalography (SEEG) is increasingly being recognized as an important invasive modality for presurgical evaluation of epilepsy. This study focuses on the clinical and technical considerations of SEEG investigations when using conventional frame-based stereotaxy, drawing on institutional experience and a comprehensive review of relevant literature.

Methods: This retrospective observational study encompassed the surgical implantation of 201 SEEG electrodes in 16 epilepsy patients using a frame-based stereotactic instrument at a single tertiary-level center. We provide detailed descriptions of the operative procedures and technical nuances for bilateral and multiple SEEG insertions, along with several illustrative cases. Additionally, we present a literature review on the technical aspects of the SEEG procedure, discussing its clinical implications and potential risks.

Results: Frame-based SEEG electrode placements were successfully performed through sagittal arc application, with the majority (81.2%) of cases being bilateral and involving up to 18 electrodes in a single operation. The median skin-to-skin operation time was 162 minutes (interquartile range [IQR], 145-200), with a median of 13 minutes (IQR, 12-15) per electrode placement for time efficiency. There were two occurrences (1.0%) of electrode misplacement and one instance (0.5%) of a postoperative complication, which manifested as a delayed intraparenchymal hemorrhage. Following SEEG investigation, 11 patients proceeded with surgical intervention, resulting in favorable seizure outcomes for nine (81.8%) and complete remission for eight cases (72.7%).

Conclusion: Conventional frame-based stereotactic techniques remain a reliable and effective option for bilateral and multiple SEEG electrode placements. While SEEG is a suitable approach for selected patients who are strong candidates for epilepsy surgery, it is important to remain vigilant concerning the potential risks of electrode misplacement and hemorrhagic complications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于框架的传统立体定向技术在立体脑电图中的临床适用性和安全性。
目的:立体脑电图(SEEG)越来越被认为是癫痫手术前评估的一种重要侵入性方式。本研究借鉴各机构的经验,并全面回顾了相关文献,重点探讨了使用传统框架立体定向法进行 SEEG 检查时的临床和技术注意事项:这项回顾性观察研究包括在一家三级医疗中心使用框架式立体定向器械为 16 名癫痫患者手术植入 201 个 SEEG 电极。我们详细描述了双侧和多侧 SEEG 植入的手术过程和技术上的细微差别,并提供了几个示例病例。此外,我们还对 SEEG 手术的技术方面进行了文献综述,讨论了其临床意义和潜在风险:通过矢状弧应用成功进行了基于框架的 SEEG 电极置入,大多数病例(81.2%)为双侧,单次手术最多涉及 18 个电极。皮对皮手术时间的中位数为 162 分钟(四分位数间距 [IQR],145-200),每次电极置入的时间效率中位数为 13 分钟(IQR,12-15)。有两例(1.0%)电极错位,一例(0.5%)术后并发症,表现为延迟性实质内出血。在进行 SEEG 检查后,11 名患者接受了手术治疗,其中 9 例(81.8%)患者的癫痫发作结果良好,8 例(72.7%)患者的癫痫发作完全缓解:结论:传统的基于框架的立体定向技术仍然是双侧和多 SEEG 电极放置的可靠而有效的选择。虽然 SEEG 是一种适用于选定的癫痫手术患者的方法,但必须对电极错位和出血并发症的潜在风险保持警惕。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
6.20%
发文量
109
审稿时长
3-8 weeks
期刊介绍: The Journal of Korean Neurosurgical Society (J Korean Neurosurg Soc) is the official journal of the Korean Neurosurgical Society, and published bimonthly (1st day of January, March, May, July, September, and November). It launched in October 31, 1972 with Volume 1 and Number 1. J Korean Neurosurg Soc aims to allow neurosurgeons from around the world to enrich their knowledge of patient management, education, and clinical or experimental research, and hence their professionalism. This journal publishes Laboratory Investigations, Clinical Articles, Review Articles, Case Reports, Technical Notes, and Letters to the Editor. Our field of interest involves clinical neurosurgery (cerebrovascular disease, neuro-oncology, skull base neurosurgery, spine, pediatric neurosurgery, functional neurosurgery, epilepsy, neuro-trauma, and peripheral nerve disease) and laboratory work in neuroscience.
期刊最新文献
Epidemiology and Functional Outcome of Acute Stroke Patients in Korea using Nationwide data. Integration of Palliative Care in Neurosurgical Critical Care : Insights from a Single-Center Perspective. Assessing and Charting the Future Path : Addressing the Decline of Brain Tumor Specialists in Korea - Insights from the Korea Brain Tumor Society (KBTS) Future Strategy Committee of 2023. Surgical Thrombectomy for Extensive Cerebral Venous Sinus Thrombosis after COVID-19 Vaccination : A Novel Surgical Technique and Literature Review. Neuro-Restorative Effect of Nimodipine and Calcitriol in 1-Methyl 4-Phenyl 1,2,3,6 Tetrahydropyridine-Induced Zebrafish Parkinson's Disease Model.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1