{"title":"The effect of illumination on the visibility of steps and ramps for people with low vision.","authors":"Quan Lei, Rachel Gage, Daniel Kersten, Gordon E Legge","doi":"10.1097/OPX.0000000000002146","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Poor visibility of indoor features such as steps and ramps can pose mobility hazards for people with low vision. For purposes of architectural design, it is important to understand how design parameters such as the illumination level of an indoor space affect the visibility of steps and ramps.</p><p><strong>Purpose: </strong>This study was aimed to examine the effect of typical variation in photopic illumination level in an indoor space on the visibility of steps and ramps for individuals with low vision.</p><p><strong>Methods: </strong>Steps and ramps were constructed in a large windowless room illuminated by overhead lights. Subjects with low vision completed a 5-alternative forced choice task to recognize the targets at three levels of photopic illumination, i.e., 800, 80, and 8 lux, and gave confidence ratings about their judgments on a 5-point scale. Acuities and contrast sensitivities of the subjects were also measured at each illumination level. For comparison, a group of normally sighted subjects with simulated acuity reduction also completed the step-and-ramp recognition task.</p><p><strong>Results: </strong>For both groups of subjects, recognition accuracy was not affected by illumination level. For subjects with low vision, however, there was a significant effect of illumination level on confidence rating: subjects became more confident about their judgments with increasing illumination. There was also a weak effect of illumination level on acuity and contrast sensitivity, both worsening with decreasing illumination. Recognition performance was best predicted by contrast sensitivity, whereas confidence was best predicted by visual acuity.</p><p><strong>Conclusions: </strong>Illumination variation over a typical photopic range in an indoor space had minimal effect on the objective visibility of steps and ramps for people with low vision. However, illumination level affected subjects' confidence in hazard recognition. Design decisions on parameters such as illumination should consider the consequences on both the objective and the subjective accessibility of a space.</p>","PeriodicalId":19649,"journal":{"name":"Optometry and Vision Science","volume":"101 6","pages":"399-407"},"PeriodicalIF":1.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry and Vision Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/OPX.0000000000002146","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Significance: Poor visibility of indoor features such as steps and ramps can pose mobility hazards for people with low vision. For purposes of architectural design, it is important to understand how design parameters such as the illumination level of an indoor space affect the visibility of steps and ramps.
Purpose: This study was aimed to examine the effect of typical variation in photopic illumination level in an indoor space on the visibility of steps and ramps for individuals with low vision.
Methods: Steps and ramps were constructed in a large windowless room illuminated by overhead lights. Subjects with low vision completed a 5-alternative forced choice task to recognize the targets at three levels of photopic illumination, i.e., 800, 80, and 8 lux, and gave confidence ratings about their judgments on a 5-point scale. Acuities and contrast sensitivities of the subjects were also measured at each illumination level. For comparison, a group of normally sighted subjects with simulated acuity reduction also completed the step-and-ramp recognition task.
Results: For both groups of subjects, recognition accuracy was not affected by illumination level. For subjects with low vision, however, there was a significant effect of illumination level on confidence rating: subjects became more confident about their judgments with increasing illumination. There was also a weak effect of illumination level on acuity and contrast sensitivity, both worsening with decreasing illumination. Recognition performance was best predicted by contrast sensitivity, whereas confidence was best predicted by visual acuity.
Conclusions: Illumination variation over a typical photopic range in an indoor space had minimal effect on the objective visibility of steps and ramps for people with low vision. However, illumination level affected subjects' confidence in hazard recognition. Design decisions on parameters such as illumination should consider the consequences on both the objective and the subjective accessibility of a space.
期刊介绍:
Optometry and Vision Science is the monthly peer-reviewed scientific publication of the American Academy of Optometry, publishing original research since 1924. Optometry and Vision Science is an internationally recognized source for education and information on current discoveries in optometry, physiological optics, vision science, and related fields. The journal considers original contributions that advance clinical practice, vision science, and public health. Authors should remember that the journal reaches readers worldwide and their submissions should be relevant and of interest to a broad audience. Topical priorities include, but are not limited to: clinical and laboratory research, evidence-based reviews, contact lenses, ocular growth and refractive error development, eye movements, visual function and perception, biology of the eye and ocular disease, epidemiology and public health, biomedical optics and instrumentation, novel and important clinical observations and treatments, and optometric education.