Safety and performance of the new med-el total ossicular replacement prostheses.

IF 1.9 3区 医学 Q2 OTORHINOLARYNGOLOGY European Archives of Oto-Rhino-Laryngology Pub Date : 2024-11-01 Epub Date: 2024-07-13 DOI:10.1007/s00405-024-08784-w
Esther Schimanski, Thomas Lenarz, Susan Busch, Susan Arndt, Christian Offergeld, Christoph Arnoldner, Dominik Riss, Joachim Hornung, Lava Taha, Paul Martin Zwittag, Nina Rubicz, Dirk Beutner, Nicholas Bevis, Benjamin Loader, Franz Windisch, Georg Sprinzl, Astrid Magele, Wendelin Wolfram, Lisa Niederwanger, Łukasz Plichta, Piotr H Skarżyński
{"title":"Safety and performance of the new med-el total ossicular replacement prostheses.","authors":"Esther Schimanski, Thomas Lenarz, Susan Busch, Susan Arndt, Christian Offergeld, Christoph Arnoldner, Dominik Riss, Joachim Hornung, Lava Taha, Paul Martin Zwittag, Nina Rubicz, Dirk Beutner, Nicholas Bevis, Benjamin Loader, Franz Windisch, Georg Sprinzl, Astrid Magele, Wendelin Wolfram, Lisa Niederwanger, Łukasz Plichta, Piotr H Skarżyński","doi":"10.1007/s00405-024-08784-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP).</p><p><strong>Methods: </strong>Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA<sub>4</sub>). The post-operative PTA<sub>4</sub> air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined.</p><p><strong>Results: </strong>103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA<sub>4</sub> ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA<sub>4</sub> ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA<sub>4</sub> ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA<sub>4</sub> (post-operative minus pre-operative BC PTA<sub>4</sub>) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA<sub>4</sub> deterioration of 11.3 dB HL.</p><p><strong>Conclusion: </strong>The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00405-024-08784-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP).

Methods: Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined.

Results: 103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA4 ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA4 ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA4 ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA4 (post-operative minus pre-operative BC PTA4) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA4 deterioration of 11.3 dB HL.

Conclusion: The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型 med-el 全骨关节置换假体的安全性和性能。
目的:这项多中心回顾性研究提供了 MED-EL 全耳廓置换假体(TORP)的安全性和性能数据:患者使用 mXACT 中心型全人工耳蜗、mXACT 非中心型全人工耳蜗或 mXACT PRO 全人工耳蜗进行鼓室成形术。对临床数据进行回顾性分析。随访检查包括查阅患者的医疗记录(了解不良事件)、耳显微镜检查和纯音测听,以确定术后 0.5、1、2 和 3 kHz 频率的纯音平均值(PTA4)。术后 PTA4 气骨间隙(ABG)用于评估听力结果。没有规定术后最短和最长随访时间:结果:103 名患者植入了 TORP。对 102 名患者(88 名成人,14 名儿童;37 名 CHL,64 名 MHL,1 名不详)进行了安全性分析,对 92 名患者(79 名成人,13 名儿童)进行了假体性能分析。不良事件结果(n = 102):1例患者(儿童,mXACT全假体偏离中心)出现假体脱位,需要进行翻修手术。没有假体挤出或移位的报告。听力结果(n = 92):92 名患者中有 49 人(53.3%)的 PTA4 ABG≤20 分贝,因此康复成功。所有 92 名患者的术后 PTA4 ABG 平均值为 21.0 ± 9.7 dB。达到了第一个终点,即术后 PTA4 ABG 改善≤ 20 dB 的患者比例≥ 25%。91名患者(98.9%)的个人Δ BC PTA4(术后减去术前 BC PTA4)阈值保持稳定(± 5 dB HL以内)。1 名患者的 BC PTA4 下降了 11.3 dB HL:结论:MED-EL TORPs 用于中耳重建安全有效。试验注册号 NCT05565339,2022 年 9 月 09 日,回顾性注册。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
7.70%
发文量
537
审稿时长
2-4 weeks
期刊介绍: Official Journal of European Union of Medical Specialists – ORL Section and Board Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery "European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level. European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.
期刊最新文献
Correction: A novel olfactory sorting task. Scale for the assessment of mucosal wave dynamics of the free edges during stroboscopic examination: clinical validation study and analysis of results. Drug induced sleep endoscopy and simultaneous polysomnography to predict the effectiveness of mandibular advancement device in obstructive sleep apnea treatment. Endoscopic revision surgery for ossicular chain reconstruction: intraoperative findings and functional outcomes. AI in oncology: comparing the diagnostic and therapeutic potential of claude 3 opus and ChatGPT 4.0 in HNSCC management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1