Outcomes of Corneal Compound Hyperopic Astigmatism With Presbyopia by Zeiss PRESBYOND Laser Blended Vision LASIK Using Default Custom Refractive Software Master Target Refractions for Reduced Anisometropia.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2024-07-01 DOI:10.3928/1081597X-20240506-02
Julia Hernández-Lucena, Federico Alonso-Aliste, Jonatan Amián-Cordero, José-María Sánchez-González
{"title":"Outcomes of Corneal Compound Hyperopic Astigmatism With Presbyopia by Zeiss PRESBYOND Laser Blended Vision LASIK Using Default Custom Refractive Software Master Target Refractions for Reduced Anisometropia.","authors":"Julia Hernández-Lucena, Federico Alonso-Aliste, Jonatan Amián-Cordero, José-María Sánchez-González","doi":"10.3928/1081597X-20240506-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period.</p><p><strong>Methods: </strong>A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes.</p><p><strong>Results: </strong>Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery.</p><p><strong>Conclusions: </strong>This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. <b>[ <i>J Refract Surg.</i> 2024;40(7):e480-e489.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 7","pages":"e480-e489"},"PeriodicalIF":2.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240506-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period.

Methods: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes.

Results: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery.

Conclusions: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
蔡司 PRESBYOND 激光混合视力 LASIK 使用默认自定义屈光软件主目标屈光度以减少散光的角膜复合远视散光与老花的疗效。
目的:评估修改后的 PRESBYOND 激光混合视力方案(卡尔蔡司医疗股份公司)的有效性、安全性和稳定性,该方案使用定制屈光软件 Master(CRSM)靶向矫正远视散光和老花眼,为期 6 个月:共有 318 名患者的 636 只眼睛符合纳入和排除标准,他们的平均年龄为 51.05 ± 4.71 岁(40 至 60 岁)。所有患者均完成了为期 6 个月的随访。使用 CRSM 软件为 MEL90 准分子激光器(卡尔蔡司医疗技术股份公司)生成消融曲线。主眼的目标屈光度为各向同性,近眼的目标屈光度为-0.75至-1.12屈光度(D):视力和屈光结果分别由优势眼和非优势眼进行研究。球面等效屈光矫正的平均尝试值为 +2.17 ± 1.16 D(范围:-1.00 至 +5.37 D)。平均尝试的圆柱度为 -0.60 ± 0.75 D(范围:-4.00 至 0.00 D)。屈光治疗后,所有单眼的未矫正远视力(UDVA)均达到或优于 20/25,其中 88% 达到 20/20。双眼视力均达到 20/25 或更高,96.54% 达到 20/20。98%的患者保持了手术前的矫正远视力和手术后 6 个月的 UDVA:采用PRESBYOND激光混合视力技术治疗远视性小散光是一种有效、安全、耐受性良好的屈光治疗方法。它是一种有效的手术,在 UDVA 和未矫正近视力方面效果极佳,并证明了双眼相加的存在。[J Refract Surg. 2024;40(7):e480-e489]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer. Clipped Topography-Guided Treatments: A Different Approach to Custom Corrections. Comparison of the Visual Outcomes and Optical Quality of Small Incision Lenticule Extraction and Toric Implantable Collamer Lens Implantation to Correct High Astigmatism. Effects and Related Factors of Short-time Accommodation Training on Measuring Consistency of InnovEyes Sitemap, Autorefraction, and Subjective Refraction. Effects of Ocular Residual Astigmatism on Refractive Outcomes for Myopia Correction After Keratorefractive Lenticule Extraction Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1