Hinrich Rahlfs, Markus Hüllebrand, Sebastian Schmitter, Christoph Strecker, Andreas Harloff, Anja Hennemuth
{"title":"Learning carotid vessel wall segmentation in black-blood MRI using sparsely sampled cross-sections from 3D data.","authors":"Hinrich Rahlfs, Markus Hüllebrand, Sebastian Schmitter, Christoph Strecker, Andreas Harloff, Anja Hennemuth","doi":"10.1117/1.JMI.11.4.044503","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Atherosclerosis of the carotid artery is a major risk factor for stroke. Quantitative assessment of the carotid vessel wall can be based on cross-sections of three-dimensional (3D) black-blood magnetic resonance imaging (MRI). To increase reproducibility, a reliable automatic segmentation in these cross-sections is essential.</p><p><strong>Approach: </strong>We propose an automatic segmentation of the carotid artery in cross-sections perpendicular to the centerline to make the segmentation invariant to the image plane orientation and allow a correct assessment of the vessel wall thickness (VWT). We trained a residual U-Net on eight sparsely sampled cross-sections per carotid artery and evaluated if the model can segment areas that are not represented in the training data. We used 218 MRI datasets of 121 subjects that show hypertension and plaque in the ICA or CCA measuring <math><mrow><mo>≥</mo> <mn>1.5</mn> <mtext> </mtext> <mi>mm</mi></mrow> </math> in ultrasound.</p><p><strong>Results: </strong>The model achieves a high mean Dice coefficient of 0.948/0.859 for the vessel's lumen/wall, a low mean Hausdorff distance of <math><mrow><mn>0.417</mn> <mo>/</mo> <mn>0.660</mn> <mtext> </mtext> <mi>mm</mi></mrow> </math> , and a low mean average contour distance of <math><mrow><mn>0.094</mn> <mo>/</mo> <mn>0.119</mn> <mtext> </mtext> <mi>mm</mi></mrow> </math> on the test set. The model reaches similar results for regions of the carotid artery that are not incorporated in the training set and on MRI of young, healthy subjects. The model also achieves a low median Hausdorff distance of <math><mrow><mn>0.437</mn> <mo>/</mo> <mn>0.552</mn> <mtext> </mtext> <mi>mm</mi></mrow> </math> on the 2021 Carotid Artery Vessel Wall Segmentation Challenge test set.</p><p><strong>Conclusions: </strong>The proposed method can reduce the effort for carotid artery vessel wall assessment. Together with human supervision, it can be used for clinical applications, as it allows a reliable measurement of the VWT for different patient demographics and MRI acquisition settings.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11245174/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.4.044503","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Atherosclerosis of the carotid artery is a major risk factor for stroke. Quantitative assessment of the carotid vessel wall can be based on cross-sections of three-dimensional (3D) black-blood magnetic resonance imaging (MRI). To increase reproducibility, a reliable automatic segmentation in these cross-sections is essential.
Approach: We propose an automatic segmentation of the carotid artery in cross-sections perpendicular to the centerline to make the segmentation invariant to the image plane orientation and allow a correct assessment of the vessel wall thickness (VWT). We trained a residual U-Net on eight sparsely sampled cross-sections per carotid artery and evaluated if the model can segment areas that are not represented in the training data. We used 218 MRI datasets of 121 subjects that show hypertension and plaque in the ICA or CCA measuring in ultrasound.
Results: The model achieves a high mean Dice coefficient of 0.948/0.859 for the vessel's lumen/wall, a low mean Hausdorff distance of , and a low mean average contour distance of on the test set. The model reaches similar results for regions of the carotid artery that are not incorporated in the training set and on MRI of young, healthy subjects. The model also achieves a low median Hausdorff distance of on the 2021 Carotid Artery Vessel Wall Segmentation Challenge test set.
Conclusions: The proposed method can reduce the effort for carotid artery vessel wall assessment. Together with human supervision, it can be used for clinical applications, as it allows a reliable measurement of the VWT for different patient demographics and MRI acquisition settings.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.