Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction.
Ronuk M Modi, Marianna Lozano Cruz Marquez, Shu Yang, Robert N D'Angelo, Timothy R Maher, Bahij Kreidieh, Nicholas O Palmeri, Hans F Stabenau, Dana Goldense, Emily Wacks, Patricia Tung, Andre d'Avila, Jonathan Waks, Peter Zimetbaum, Andrew H Locke
{"title":"Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction.","authors":"Ronuk M Modi, Marianna Lozano Cruz Marquez, Shu Yang, Robert N D'Angelo, Timothy R Maher, Bahij Kreidieh, Nicholas O Palmeri, Hans F Stabenau, Dana Goldense, Emily Wacks, Patricia Tung, Andre d'Avila, Jonathan Waks, Peter Zimetbaum, Andrew H Locke","doi":"10.19102/icrm.2024.15071","DOIUrl":null,"url":null,"abstract":"<p><p>With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.</p>","PeriodicalId":36299,"journal":{"name":"Journal of Innovations in Cardiac Rhythm Management","volume":"15 7","pages":"5930-5934"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11238887/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Cardiac Rhythm Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19102/icrm.2024.15071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.