{"title":"Incisura tangent method to determine the transsyndesmotic axis for syndesmotic fixation.","authors":"Toshinari Mashu, Satoshi Yamaguchi, Seiji Kimura, Hirofumi Nakajima, Manato Horii, Shotaro Watanabe, Ryu Ito, Takahisa Sasho, Seiji Ohtori","doi":"10.1016/j.fas.2024.06.008","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods.</p><p><strong>Methods: </strong>We analyzed computed tomographic images of 43 normal ankles. The IT view was simulated using a digitally reconstructed radiograph, in which the anterior and posterior fibular incisura tubercles overlapped on the internally rotated anteroposterior view. The interaxis angle between the TS and the axes determined by the IT method was measured on the axial computed tomographic image corresponding to the radiographic image. The same procedure was repeated using the CC and TL methods. The measured values were compared between the three methods using a one-factor analysis of variance. Furthermore, the measurements of the anteverted and retroverted incisurae were compared for each fluoroscopic method.</p><p><strong>Results: </strong>The mean interaxis angles between the TS were - 0.5 degrees, 6.3 degrees, and - 1.8 degrees for the IT, CC, and TL methods, respectively, with a significantly larger value for the CC method than for the IT and TL methods (P < .001). No significant difference was found in the interaxis angle in the anteverted (-0.1 degrees) and retroverted (-1.0 degrees) incisurae when using the IT method (P = .15). The angles in the retroverted incisurae were larger than those of the anteverted incisurae for the CC and TL methods.</p><p><strong>Conclusion: </strong>The fluoroscopic IT method accurately estimated the TS axis. The interaxis angles were consistent, regardless of the incisura anatomy. The fluoroscopic method can be used to clamp and fix the syndesmosis along the TS axis.</p><p><strong>Level of evidence: </strong>Ⅳ.</p>","PeriodicalId":48743,"journal":{"name":"Foot and Ankle Surgery","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.fas.2024.06.008","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods.
Methods: We analyzed computed tomographic images of 43 normal ankles. The IT view was simulated using a digitally reconstructed radiograph, in which the anterior and posterior fibular incisura tubercles overlapped on the internally rotated anteroposterior view. The interaxis angle between the TS and the axes determined by the IT method was measured on the axial computed tomographic image corresponding to the radiographic image. The same procedure was repeated using the CC and TL methods. The measured values were compared between the three methods using a one-factor analysis of variance. Furthermore, the measurements of the anteverted and retroverted incisurae were compared for each fluoroscopic method.
Results: The mean interaxis angles between the TS were - 0.5 degrees, 6.3 degrees, and - 1.8 degrees for the IT, CC, and TL methods, respectively, with a significantly larger value for the CC method than for the IT and TL methods (P < .001). No significant difference was found in the interaxis angle in the anteverted (-0.1 degrees) and retroverted (-1.0 degrees) incisurae when using the IT method (P = .15). The angles in the retroverted incisurae were larger than those of the anteverted incisurae for the CC and TL methods.
Conclusion: The fluoroscopic IT method accurately estimated the TS axis. The interaxis angles were consistent, regardless of the incisura anatomy. The fluoroscopic method can be used to clamp and fix the syndesmosis along the TS axis.
期刊介绍:
Foot and Ankle Surgery is essential reading for everyone interested in the foot and ankle and its disorders. The approach is broad and includes all aspects of the subject from basic science to clinical management. Problems of both children and adults are included, as is trauma and chronic disease. Foot and Ankle Surgery is the official journal of European Foot and Ankle Society.
The aims of this journal are to promote the art and science of ankle and foot surgery, to publish peer-reviewed research articles, to provide regular reviews by acknowledged experts on common problems, and to provide a forum for discussion with letters to the Editors. Reviews of books are also published. Papers are invited for possible publication in Foot and Ankle Surgery on the understanding that the material has not been published elsewhere or accepted for publication in another journal and does not infringe prior copyright.