Nico Erhard MD, Florian Englert MD, Simon Prommersberger MD, Miruna Popa MD, Felix Bourier MD, Tilko Reents MD, Hannah Kraft MD, Alex Tunsch Martinez MD, Jan Syväri MD, Madeleine Tydecks MD, Edison Abdiu MD, Eva Koops MD, Theresa Reiter MD, Marta Telishevska MD, Sarah Lengauer MD, Gabriele Hessling MD, Isabel Deisenhofer MD, FHRS, Fabian Bahlke MD
{"title":"Focal pulsed field ablation in complex atrial tachycardia: First clinical experience and 1-year outcome","authors":"Nico Erhard MD, Florian Englert MD, Simon Prommersberger MD, Miruna Popa MD, Felix Bourier MD, Tilko Reents MD, Hannah Kraft MD, Alex Tunsch Martinez MD, Jan Syväri MD, Madeleine Tydecks MD, Edison Abdiu MD, Eva Koops MD, Theresa Reiter MD, Marta Telishevska MD, Sarah Lengauer MD, Gabriele Hessling MD, Isabel Deisenhofer MD, FHRS, Fabian Bahlke MD","doi":"10.1016/j.hrthm.2024.07.024","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique.</div></div><div><h3>Objective</h3><div>The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT).</div></div><div><h3>Methods</h3><div>All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force–sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner.</div></div><div><h3>Results</h3><div>Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation.</div></div><div><h3>Conclusion</h3><div>Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.</div></div>","PeriodicalId":12886,"journal":{"name":"Heart rhythm","volume":"22 1","pages":"Pages 57-64"},"PeriodicalIF":5.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart rhythm","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1547527124029059","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique.
Objective
The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT).
Methods
All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force–sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner.
Results
Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation.
Conclusion
Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.
期刊介绍:
HeartRhythm, the official Journal of the Heart Rhythm Society and the Cardiac Electrophysiology Society, is a unique journal for fundamental discovery and clinical applicability.
HeartRhythm integrates the entire cardiac electrophysiology (EP) community from basic and clinical academic researchers, private practitioners, engineers, allied professionals, industry, and trainees, all of whom are vital and interdependent members of our EP community.
The Heart Rhythm Society is the international leader in science, education, and advocacy for cardiac arrhythmia professionals and patients, and the primary information resource on heart rhythm disorders. Its mission is to improve the care of patients by promoting research, education, and optimal health care policies and standards.