Jakub Maksym, Piotr Scisło, Agnieszka Kapłon-Cieślicka, Zenon Huczek, Michał Marchel, Janusz Kochman, Karol Zbroński, Grzegorz Opolski, Marcin Grabowski, Tomasz Mazurek
{"title":"Incidence and predictors of device-related thrombus after left atrial appendage closure with Watchman device.","authors":"Jakub Maksym, Piotr Scisło, Agnieszka Kapłon-Cieślicka, Zenon Huczek, Michał Marchel, Janusz Kochman, Karol Zbroński, Grzegorz Opolski, Marcin Grabowski, Tomasz Mazurek","doi":"10.5114/aic.2024.140315","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Left atrial appendage closure (LAAC) with Watchman device prevents thromboembolism in patients with atrial fibrillation (AF). However, thrombus may develop on the atrial surface of the device.</p><p><strong>Aim: </strong>To investigate the incidence and predictors of device-related thrombus (DRT) in patients with AF who were treated with LAAC.</p><p><strong>Material and methods: </strong>Ninety-one consecutive patients with AF underwent LAAC procedure using first-generation Watchman 2.5 device followed by antiplatelet therapy. In our analysis we have included all patients (<i>n</i> = 78) who had clinical follow-up visits with transesophageal echocardiography (TEE) after the procedure.</p><p><strong>Results: </strong>The median (IQR) CHA<sub>2</sub>DS<sub>2</sub>-VASc score was 4 (4.0-6.0) and HAS-BLED score was 3 (3.0-4.0). DRTs were observed in 5 (6.4%) patients. When compared with patients without DRT, those with DRT presented more often with lower median ejection fraction (40% (23.5-45.5) versus 55% (48.0-60.0); <i>p</i> = 0.005), lower emptying velocity of LAA (25 cm/s (17.5-27.0) versus 53 cm/s (26.5-78.0); <i>p</i> = 0.009), and with greater depth of implantation (18 mm (14.0-20.5) versus 8 mm (5.0-11.0); <i>p</i> < 0.001). Furthermore, patients with DRT had greater depth of LAA (35 mm (29.5-41.0) versus 29 mm (25.5-31.0); <i>p</i> = 0.003), greater mean (SD) dimension in 90<sup>0</sup> (22.4 mm (3.2) versus 19 mm (2.7); <i>p</i> = 0.02). Patients with DRT were also younger than those without DRT (67.4 years (7) versus 75 years (8.3), <i>p</i> = 0.045).</p><p><strong>Conclusions: </strong>The DRT after Watchman device implantation remains a rare complication. Its formation was related to several patient and procedural characteristics, which need to be confirmed in larger studies.</p>","PeriodicalId":49678,"journal":{"name":"Postepy W Kardiologii Interwencyjnej","volume":"20 2","pages":"164-171"},"PeriodicalIF":1.5000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249867/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Postepy W Kardiologii Interwencyjnej","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/aic.2024.140315","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Left atrial appendage closure (LAAC) with Watchman device prevents thromboembolism in patients with atrial fibrillation (AF). However, thrombus may develop on the atrial surface of the device.
Aim: To investigate the incidence and predictors of device-related thrombus (DRT) in patients with AF who were treated with LAAC.
Material and methods: Ninety-one consecutive patients with AF underwent LAAC procedure using first-generation Watchman 2.5 device followed by antiplatelet therapy. In our analysis we have included all patients (n = 78) who had clinical follow-up visits with transesophageal echocardiography (TEE) after the procedure.
Results: The median (IQR) CHA2DS2-VASc score was 4 (4.0-6.0) and HAS-BLED score was 3 (3.0-4.0). DRTs were observed in 5 (6.4%) patients. When compared with patients without DRT, those with DRT presented more often with lower median ejection fraction (40% (23.5-45.5) versus 55% (48.0-60.0); p = 0.005), lower emptying velocity of LAA (25 cm/s (17.5-27.0) versus 53 cm/s (26.5-78.0); p = 0.009), and with greater depth of implantation (18 mm (14.0-20.5) versus 8 mm (5.0-11.0); p < 0.001). Furthermore, patients with DRT had greater depth of LAA (35 mm (29.5-41.0) versus 29 mm (25.5-31.0); p = 0.003), greater mean (SD) dimension in 900 (22.4 mm (3.2) versus 19 mm (2.7); p = 0.02). Patients with DRT were also younger than those without DRT (67.4 years (7) versus 75 years (8.3), p = 0.045).
Conclusions: The DRT after Watchman device implantation remains a rare complication. Its formation was related to several patient and procedural characteristics, which need to be confirmed in larger studies.
期刊介绍:
Postępy w Kardiologii Interwencyjnej/Advances in Interventional Cardiology is indexed in:
Index Copernicus, Ministry of Science and Higher Education Index (MNiSW).
Advances in Interventional Cardiology is a quarterly aimed at specialists, mainly at cardiologists and cardiosurgeons.
Official journal of the Association on Cardiovascular Interventions of the Polish Cardiac Society.