Ahmed A. M. AL-Shaar, Ibrahim S. I. Harba, Abdulkhalik J. Abdulridha
{"title":"Nonlinear finite element analysis of steel moment-resisting frames with shear fuse under seismic loading","authors":"Ahmed A. M. AL-Shaar, Ibrahim S. I. Harba, Abdulkhalik J. Abdulridha","doi":"10.1007/s42107-024-01117-6","DOIUrl":null,"url":null,"abstract":"<div><p>This study investigates the impact of shear fuse link length and position on the seismic response of multi-story steel frames. Pushover evaluation and nonlinear time history analysis were applied to steel frames with varied link lengths (0.5 m, 0.75 m, 1 m) and locations (all beams, side beams, and middle beams) to predict earthquake effects. The numerical study assessed the seismic performance of 4, 8, and 12-story steel moment-resistant frames. In the investigation, 30 models will be tested using three earthquakes: Halabjah, EL-Centro, and Northridge. The data show that increasing shear fuse link length improves lateral displacements and drifts for all building heights (four, eight, and twelve stories), especially during high-intensity earthquakes. In contrast, the impact on base shear ability is exceedingly complex, most likely varying with building height and earthquake characteristics. In some circumstances, shorter links benefit low-rise frames, while longer links may favor taller frames. Shear fuse-links can significantly improve the seismic performance of steel frames by distributing energy and introducing protective structural elements. Shorter connections may be desirable for displacement management in low-story (4-story) constructions, whereas more extended linkages are likely required to maintain base shear capacity in taller (8-story) frames. Positioning linkages in all beams maximizes energy dissipation while achieving optimal displacement and drift. Pushover testing demonstrates the effectiveness of shear fuse linkages in increasing energy dissipation and safeguarding various structural parts.</p></div>","PeriodicalId":8513,"journal":{"name":"Asian Journal of Civil Engineering","volume":"25 7","pages":"5349 - 5375"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1007/s42107-024-01117-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
This study investigates the impact of shear fuse link length and position on the seismic response of multi-story steel frames. Pushover evaluation and nonlinear time history analysis were applied to steel frames with varied link lengths (0.5 m, 0.75 m, 1 m) and locations (all beams, side beams, and middle beams) to predict earthquake effects. The numerical study assessed the seismic performance of 4, 8, and 12-story steel moment-resistant frames. In the investigation, 30 models will be tested using three earthquakes: Halabjah, EL-Centro, and Northridge. The data show that increasing shear fuse link length improves lateral displacements and drifts for all building heights (four, eight, and twelve stories), especially during high-intensity earthquakes. In contrast, the impact on base shear ability is exceedingly complex, most likely varying with building height and earthquake characteristics. In some circumstances, shorter links benefit low-rise frames, while longer links may favor taller frames. Shear fuse-links can significantly improve the seismic performance of steel frames by distributing energy and introducing protective structural elements. Shorter connections may be desirable for displacement management in low-story (4-story) constructions, whereas more extended linkages are likely required to maintain base shear capacity in taller (8-story) frames. Positioning linkages in all beams maximizes energy dissipation while achieving optimal displacement and drift. Pushover testing demonstrates the effectiveness of shear fuse linkages in increasing energy dissipation and safeguarding various structural parts.
期刊介绍:
The Asian Journal of Civil Engineering (Building and Housing) welcomes articles and research contributions on topics such as:- Structural analysis and design - Earthquake and structural engineering - New building materials and concrete technology - Sustainable building and energy conservation - Housing and planning - Construction management - Optimal design of structuresPlease note that the journal will not accept papers in the area of hydraulic or geotechnical engineering, traffic/transportation or road making engineering, and on materials relevant to non-structural buildings, e.g. materials for road making and asphalt. Although the journal will publish authoritative papers on theoretical and experimental research works and advanced applications, it may also feature, when appropriate: a) tutorial survey type papers reviewing some fields of civil engineering; b) short communications and research notes; c) book reviews and conference announcements.