Sirawich Chaiparnich, O. Poachanukoon, Natcha Manasilp, N. Saiphoklang, C. Tantibundhit, P. Vatcharavongvan, Pattapol Kunumpol, Phongpan Plienphanich, A. Pugongchai, K. Leelasittikul, Nantavat Prompoom
{"title":"The comparison study on accuracy of peak expiratory flow rate measurement by PRAAN, spirometry, and the mini-Wright peak flow meter Â","authors":"Sirawich Chaiparnich, O. Poachanukoon, Natcha Manasilp, N. Saiphoklang, C. Tantibundhit, P. Vatcharavongvan, Pattapol Kunumpol, Phongpan Plienphanich, A. Pugongchai, K. Leelasittikul, Nantavat Prompoom","doi":"10.12688/f1000research.144927.1","DOIUrl":null,"url":null,"abstract":"Background PRAAN, a digital peak flow meter, was developed to measure peak expiratory flow rate (PEFR) for asthma monitoring. This study aimed to compare PRAAN’s accuracy to that of spirometry and the mini-Wright peak flow meter for PEFR measurement. Methods Two cross-sectional studies were conducted in 106 healthy adult participants. Study A (n=56) compared PRAAN with spirometry, while study B (n=50) compared PRAAN with the mini-Wright peak flow meter. PEFR values were collected using crossover studies. Pearson’s correlation and Bland-Altman plots were used to report the relationship and agreement between two measurements, respectively. Results In study A, 51.8% were female, mean age was 24.3±5.6 years, and PEFR was 480.3±86.8 L/min. PEFR measured by PRAAN had very strongly positive correlation with spirometry (r=0.980, P<0.001). Bland-Altman analysis showed that there was good agreement between them, with a low mean difference of -7.07 liters/minute (95% CI: -40.58 to 26.44 liters/minute) and 92.9%, which were within the limit of agreement (LOA). In study B, 54.0% were female, mean age was 23.5±2.4 years, and PEFR was 495.1±82.7 L/min. PEFR measured by PRAAN and by the mini-Wright peak flow meter showed very strongly positive correlation (r=0.971, P<0.001). Bland-Altman comparison of PEFR between these two measurements showed that there was a very good agreement between them, with a low mean difference of 0.84 liters/minute (95% CI: -38.68 to 40.38 liters/minute) and 94.0%, which were within LOA. Conclusions The accuracy of PRAAN is in the agreement with spirometry and the mini-Wright peak flow meter. The clinical application of PRAAN may potentially lead to a monitoring strategy that healthcare providers can use to improve the management of asthma.","PeriodicalId":12260,"journal":{"name":"F1000Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"F1000Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/f1000research.144927.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0
Abstract
Background PRAAN, a digital peak flow meter, was developed to measure peak expiratory flow rate (PEFR) for asthma monitoring. This study aimed to compare PRAAN’s accuracy to that of spirometry and the mini-Wright peak flow meter for PEFR measurement. Methods Two cross-sectional studies were conducted in 106 healthy adult participants. Study A (n=56) compared PRAAN with spirometry, while study B (n=50) compared PRAAN with the mini-Wright peak flow meter. PEFR values were collected using crossover studies. Pearson’s correlation and Bland-Altman plots were used to report the relationship and agreement between two measurements, respectively. Results In study A, 51.8% were female, mean age was 24.3±5.6 years, and PEFR was 480.3±86.8 L/min. PEFR measured by PRAAN had very strongly positive correlation with spirometry (r=0.980, P<0.001). Bland-Altman analysis showed that there was good agreement between them, with a low mean difference of -7.07 liters/minute (95% CI: -40.58 to 26.44 liters/minute) and 92.9%, which were within the limit of agreement (LOA). In study B, 54.0% were female, mean age was 23.5±2.4 years, and PEFR was 495.1±82.7 L/min. PEFR measured by PRAAN and by the mini-Wright peak flow meter showed very strongly positive correlation (r=0.971, P<0.001). Bland-Altman comparison of PEFR between these two measurements showed that there was a very good agreement between them, with a low mean difference of 0.84 liters/minute (95% CI: -38.68 to 40.38 liters/minute) and 94.0%, which were within LOA. Conclusions The accuracy of PRAAN is in the agreement with spirometry and the mini-Wright peak flow meter. The clinical application of PRAAN may potentially lead to a monitoring strategy that healthcare providers can use to improve the management of asthma.
F1000ResearchPharmacology, Toxicology and Pharmaceutics-Pharmacology, Toxicology and Pharmaceutics (all)
CiteScore
5.00
自引率
0.00%
发文量
1646
审稿时长
1 weeks
期刊介绍:
F1000Research publishes articles and other research outputs reporting basic scientific, scholarly, translational and clinical research across the physical and life sciences, engineering, medicine, social sciences and humanities. F1000Research is a scholarly publication platform set up for the scientific, scholarly and medical research community; each article has at least one author who is a qualified researcher, scholar or clinician actively working in their speciality and who has made a key contribution to the article. Articles must be original (not duplications). All research is suitable irrespective of the perceived level of interest or novelty; we welcome confirmatory and negative results, as well as null studies. F1000Research publishes different type of research, including clinical trials, systematic reviews, software tools, method articles, and many others. Reviews and Opinion articles providing a balanced and comprehensive overview of the latest discoveries in a particular field, or presenting a personal perspective on recent developments, are also welcome. See the full list of article types we accept for more information.