Energy Efficient Downsizing of Ribbed Confinements for Heat Exchange Applications

IF 1.6 4区 工程技术 Q3 ENGINEERING, MECHANICAL Journal of Thermal Science and Engineering Applications Pub Date : 2024-07-03 DOI:10.1115/1.4065896
Prabhav Agrawala, Yatharth Lilhare, Amit Arora
{"title":"Energy Efficient Downsizing of Ribbed Confinements for Heat Exchange Applications","authors":"Prabhav Agrawala, Yatharth Lilhare, Amit Arora","doi":"10.1115/1.4065896","DOIUrl":null,"url":null,"abstract":"\n Downsizing double-pipe heat exchangers is possible by deploying ribs on the two sides of the heat exchangers. The shape of these ribs, along with two key geometric variables – pitch and height, are crucial in the selection of energy-efficient rib configurations. This is because, the enhancement in heat transfer performance comes at the cost of increased pressure drop. Thus, the goal of this three-dimensional numerical investigation is to identify favourable rib shapes and explore the effect of truncation on triangular ribs, something which is missing from existing literature. Truncation is expected to greatly affect the performance of triangular ribs, either adversely or favorably. To explore this conclusively, an unbiased and exhaustive analysis is carried out by comparing the performance of confinements with modified and regular triangular ribs, keeping plain confinements as the baseline. Furthermore, the effects of two principal design variables – rib height and rib pitch are explored for each shape. Separate results are presented for the inner and outer confinements of the double-pipe heat exchangers (pipes and annuli) to allow for the extrapolation of results for a wide range of applications employing internal flows in pipes and annuli. A phenomenological model is developed to classify the thermo-hydraulic performance of each confinement and identify optimal geometrical configuration and identify best performing design(s). Once optimal rib pitch-height combinations are identified, performance at this optimal combination is evaluated at different Reynolds numbers, spanning from 10,000 to 30,000.","PeriodicalId":17404,"journal":{"name":"Journal of Thermal Science and Engineering Applications","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Science and Engineering Applications","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4065896","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Downsizing double-pipe heat exchangers is possible by deploying ribs on the two sides of the heat exchangers. The shape of these ribs, along with two key geometric variables – pitch and height, are crucial in the selection of energy-efficient rib configurations. This is because, the enhancement in heat transfer performance comes at the cost of increased pressure drop. Thus, the goal of this three-dimensional numerical investigation is to identify favourable rib shapes and explore the effect of truncation on triangular ribs, something which is missing from existing literature. Truncation is expected to greatly affect the performance of triangular ribs, either adversely or favorably. To explore this conclusively, an unbiased and exhaustive analysis is carried out by comparing the performance of confinements with modified and regular triangular ribs, keeping plain confinements as the baseline. Furthermore, the effects of two principal design variables – rib height and rib pitch are explored for each shape. Separate results are presented for the inner and outer confinements of the double-pipe heat exchangers (pipes and annuli) to allow for the extrapolation of results for a wide range of applications employing internal flows in pipes and annuli. A phenomenological model is developed to classify the thermo-hydraulic performance of each confinement and identify optimal geometrical configuration and identify best performing design(s). Once optimal rib pitch-height combinations are identified, performance at this optimal combination is evaluated at different Reynolds numbers, spanning from 10,000 to 30,000.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于热交换应用的带肋密闭装置的节能缩减
通过在热交换器的两侧配置肋片,可以缩小双管热交换器的尺寸。这些肋片的形状以及两个关键的几何变量--间距和高度--是选择节能肋片配置的关键。这是因为,提高传热性能的代价是增加压降。因此,本次三维数值研究的目标是确定有利的肋条形状,并探索截断对三角形肋条的影响,这是现有文献中所缺乏的。截断预计会极大地影响三角筋的性能,无论是不利还是有利。为了对这一问题进行深入探讨,我们进行了无偏见的详尽分析,比较了带有改进型和常规型三角筋的约束性能,并将普通约束作为基线。此外,还探讨了肋高和肋间距这两个主要设计变量对每种形状的影响。针对双管热交换器(管道和环形结构)的内部和外部约束条件分别给出了结果,以便对管道和环形结构中采用内部流动的各种应用进行推断。我们开发了一个现象学模型,用于对每种封闭装置的热流体力学性能进行分类,并确定最佳几何配置和最佳性能设计。一旦确定了最佳肋片间距-高度组合,就会在 10,000 到 30,000 之间的不同雷诺数下对该最佳组合的性能进行评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Thermal Science and Engineering Applications
Journal of Thermal Science and Engineering Applications THERMODYNAMICSENGINEERING, MECHANICAL -ENGINEERING, MECHANICAL
CiteScore
3.60
自引率
9.50%
发文量
120
期刊介绍: Applications in: Aerospace systems; Gas turbines; Biotechnology; Defense systems; Electronic and photonic equipment; Energy systems; Manufacturing; Refrigeration and air conditioning; Homeland security systems; Micro- and nanoscale devices; Petrochemical processing; Medical systems; Energy efficiency; Sustainability; Solar systems; Combustion systems
期刊最新文献
Design of the Cooling Water System Upgrade for 42T Resistive Magnet at the CHMFL Energy Efficient Downsizing of Ribbed Confinements for Heat Exchange Applications Enhancing Computational Efficiency in Porous Media Analysis: Integrating Machine Learning with Monte Carlo Ray Tracing SIMULATIONS WITH COMPRESSIBLE MULTIPHASE FORMULATION ON HEAT TRANSFER STUDIES IN A ROCKET THRUST CHAMBER WITH EXPERIMENTAL VALIDATION Influence of the presence of different signatures on the heat transfer profile of laminar flow inside a microchannel.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1