{"title":"Compensation method of the spiral bevel gear tooth surface error based on eight tooth-surface fitting","authors":"Lihua Zhou, Suping Fang, Yongsheng Liu, Yuan Li, Ryohei Takeda, Tetsuya Taguchi","doi":"10.1088/1361-6501/ad5ea8","DOIUrl":null,"url":null,"abstract":"\n The misalignment error between the gear theoretical coordinate system and actual gear coordinate system is illustrated, as well as its influence on the measurement of tooth surface deviation is discussed. On the analysis of the tooth convex and concave surface error measurement process, the measured points in the theoretical coordinate system are transformed from the actual measured points in the actual coordinate system. Then, an eight tooth-surface fitting method is utilized to calculate the misalignment error and the compensation method is given. Finally, actual measurements of three different spiral bevel gears are analyzed, and the misalignment error are calculated. Using the proposed compensation method, both the eccentricity and tilt are compensated to some extent. And the machining suggestions of each spiral bevel gear are also given according to its compensated tooth surface error distribution.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"195 4","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6501/ad5ea8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
The misalignment error between the gear theoretical coordinate system and actual gear coordinate system is illustrated, as well as its influence on the measurement of tooth surface deviation is discussed. On the analysis of the tooth convex and concave surface error measurement process, the measured points in the theoretical coordinate system are transformed from the actual measured points in the actual coordinate system. Then, an eight tooth-surface fitting method is utilized to calculate the misalignment error and the compensation method is given. Finally, actual measurements of three different spiral bevel gears are analyzed, and the misalignment error are calculated. Using the proposed compensation method, both the eccentricity and tilt are compensated to some extent. And the machining suggestions of each spiral bevel gear are also given according to its compensated tooth surface error distribution.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.