Ocular biometry and anthropometric measurements in young myopes – A case–control study

Venipriya Sigamani, Viswesh Kathavarayan, Lalithambigai Chellamuthu, Ravichandran Kandasamy, H. Prasanth
{"title":"Ocular biometry and anthropometric measurements in young myopes – A case–control study","authors":"Venipriya Sigamani, Viswesh Kathavarayan, Lalithambigai Chellamuthu, Ravichandran Kandasamy, H. Prasanth","doi":"10.3126/ajms.v15i7.64751","DOIUrl":null,"url":null,"abstract":"Background: The prevalence of myopia in the 5–15-year age group in India has been 7.5% over the past four decades. While ocular growth and physical growth occur simultaneously during early life, the existence of a common regulatory system for both is still debated.\nAims and Objectives: This study aims to analyze the ocular biometry and anthropometric values of young myopes and emmetropes aged 18–25 years.\nMaterials and Methods: This case–control study involved a sample size of 86 participants. Corneal curvature was measured using keratometry, while A-scan ultrasonography was utilized to measure axial length, lens thickness, anterior chamber depth, and vitreous chamber depth.\nResults: The results indicated that there were no significant differences in ocular biometry and anthropometric values between the case and control groups, except for corneal thickness and axial length. The mean corneal thickness was found to be 549.64 μm in the case group and 566.05 μm in the control group, while the mean axial length was 24.70 mm in the case group and 23.41 mm in the control group. An increase in height was correlated with longer axial length in myopes.\nConclusion: There was no difference in anthropometry and ocular biometry in emmetropes and myopes in the age group of 18–25 years of age. Myopes tend to have thinner corneas, which should be taken into consideration before performing refractive surgeries. The presence of thin corneas in individuals with myopia can result in inaccurately low measurements of intraocular pressure, potentially hampering the early detection of glaucoma within this high-risk demographic.","PeriodicalId":8522,"journal":{"name":"Asian Journal of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/ajms.v15i7.64751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The prevalence of myopia in the 5–15-year age group in India has been 7.5% over the past four decades. While ocular growth and physical growth occur simultaneously during early life, the existence of a common regulatory system for both is still debated. Aims and Objectives: This study aims to analyze the ocular biometry and anthropometric values of young myopes and emmetropes aged 18–25 years. Materials and Methods: This case–control study involved a sample size of 86 participants. Corneal curvature was measured using keratometry, while A-scan ultrasonography was utilized to measure axial length, lens thickness, anterior chamber depth, and vitreous chamber depth. Results: The results indicated that there were no significant differences in ocular biometry and anthropometric values between the case and control groups, except for corneal thickness and axial length. The mean corneal thickness was found to be 549.64 μm in the case group and 566.05 μm in the control group, while the mean axial length was 24.70 mm in the case group and 23.41 mm in the control group. An increase in height was correlated with longer axial length in myopes. Conclusion: There was no difference in anthropometry and ocular biometry in emmetropes and myopes in the age group of 18–25 years of age. Myopes tend to have thinner corneas, which should be taken into consideration before performing refractive surgeries. The presence of thin corneas in individuals with myopia can result in inaccurately low measurements of intraocular pressure, potentially hampering the early detection of glaucoma within this high-risk demographic.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
青少年近视患者的眼部生物测量和人体测量--病例对照研究
背景:过去 40 年间,印度 5-15 岁年龄组的近视率为 7.5%。虽然眼部发育和身体发育在生命早期同时发生,但两者是否存在一个共同的调节系统仍存在争议:本研究旨在分析 18-25 岁青少年近视和散光患者的眼部生物测量和人体测量值:这项病例对照研究的样本量为 86 人。使用角膜曲率计测量角膜曲率,同时使用 A 型超声波扫描仪测量轴长、晶状体厚度、前房深度和玻璃体腔深度:结果表明,除角膜厚度和眼轴长度外,病例组和对照组的眼部生物测量和人体测量值无明显差异。病例组的平均角膜厚度为 549.64 μm,对照组为 566.05 μm;病例组的平均轴长为 24.70 mm,对照组为 23.41 mm。结论:结论:18-25 岁年龄组的近视眼和散光眼在人体测量和眼部生物测量方面没有差异。近视者的角膜往往较薄,在进行屈光手术前应考虑到这一点。近视患者的角膜较薄,可能导致眼压测量值过低,从而影响对这一高危人群青光眼的早期发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
A comparative study of efficacy of intravenous dexmedetomidine with perineural dexmedetomidine as adjuvant to ropivacaine in supraclavicular brachial plexus block in upper limb surgery Efficacy and safety of low-dose celecoxib with chemoradiation in locally advanced head-and-neck squamous cell carcinoma Comparison between mini-percutaneous nephrolithotomy and retrograde intra renal surgery for the management of lower calyceal calculi of size less than 1.5 cm : Our institutional experience A study on clinicoradiological profile of patients with hydropneumothorax in a tertiary care hospital in Eastern India Role of low-dose deflazacort with tamsulosin versus tamsulosin alone for medical expulsive therapy of ureteric stone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1