{"title":"Evaluation of cardiac output in neonatal sepsis","authors":"Angana Bhattacharjee, Saugata Chaudhuri, Maitreyi Basu","doi":"10.3126/ajms.v15i7.65989","DOIUrl":null,"url":null,"abstract":"Background: Neonatal sepsis is a clinical syndrome characterized by signs and symptoms of infection with or without accompanying bacteremia in the 1st month of life imposing significant cardiovascular compromise which poses a huge burden of morbidity. The essential objective of functional neonatal echocardiography is to recognize features of cardiovascular compromise earlier and help in timely institution of management. This study provides an overview regarding the variability of cardiac output (CO) in neonates with culture-positive sepsis.\nAims and Objectives: The aims and objectives of the study are to assess the variability of CO in term neonates with Gram-positive sepsis and Gram-negative sepsis.\nMaterials and Methods: The observational cross-sectional study was conducted in the Department of Paediatrics for 18 months in a tertiary care center. 2D echocardiography was performed on all the neonates who came positive for sepsis screen within the first 2 days of institution of antibiotics. CO was calculated from the echocardiographic finding of Aortic Root Diameter (d), Velocity Time Integral, and Heart Rate recorded at the same time. Normal range of left ventricular output has been defined as 150–300 mL/kg/min each.\nResults: In Gram-negative group, the mean CO (Mean±SD) of patients was 386.4545±34.2284 mL/kg/min while in Gram-positive group, the mean CO (Mean±SD) of patients was 345.1532±37.6044 mL/kg/min and the variation stands significant at P<0.0001.\nConclusion: This research confers about hyperdynamic circulatory status of neonatal sepsis as reflected by increased CO beyond the normal limit in septic neonates. On comparison, a strikingly higher CO was observed in Gram-negative sepsis group than Gram-positive group.","PeriodicalId":8522,"journal":{"name":"Asian Journal of Medical Sciences","volume":"468 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/ajms.v15i7.65989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Neonatal sepsis is a clinical syndrome characterized by signs and symptoms of infection with or without accompanying bacteremia in the 1st month of life imposing significant cardiovascular compromise which poses a huge burden of morbidity. The essential objective of functional neonatal echocardiography is to recognize features of cardiovascular compromise earlier and help in timely institution of management. This study provides an overview regarding the variability of cardiac output (CO) in neonates with culture-positive sepsis.
Aims and Objectives: The aims and objectives of the study are to assess the variability of CO in term neonates with Gram-positive sepsis and Gram-negative sepsis.
Materials and Methods: The observational cross-sectional study was conducted in the Department of Paediatrics for 18 months in a tertiary care center. 2D echocardiography was performed on all the neonates who came positive for sepsis screen within the first 2 days of institution of antibiotics. CO was calculated from the echocardiographic finding of Aortic Root Diameter (d), Velocity Time Integral, and Heart Rate recorded at the same time. Normal range of left ventricular output has been defined as 150–300 mL/kg/min each.
Results: In Gram-negative group, the mean CO (Mean±SD) of patients was 386.4545±34.2284 mL/kg/min while in Gram-positive group, the mean CO (Mean±SD) of patients was 345.1532±37.6044 mL/kg/min and the variation stands significant at P<0.0001.
Conclusion: This research confers about hyperdynamic circulatory status of neonatal sepsis as reflected by increased CO beyond the normal limit in septic neonates. On comparison, a strikingly higher CO was observed in Gram-negative sepsis group than Gram-positive group.