Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5-7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial.

IF 1.6 3区 医学 Q2 SURGERY BMC Surgery Pub Date : 2024-07-19 DOI:10.1186/s12893-024-02497-x
Xipeng Wang, Chengqiang Li, Junqiang Fan, Jian Hu, Mingsong Wang, Hecheng Li
{"title":"Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5-7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial.","authors":"Xipeng Wang, Chengqiang Li, Junqiang Fan, Jian Hu, Mingsong Wang, Hecheng Li","doi":"10.1186/s12893-024-02497-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The ultrasonic scalpel is widely used during surgery. It is safe and effective to close the pulmonary artery branch vessels of 7 mm or below with an ultrasonic energy device as reported. However, there have been no multicenter randomized clinical trial to assess the safety and effectiveness of using ultrasonic scalpel to coagulate 5-7 mm blood vessels in thoracic surgery.</p><p><strong>Methods: </strong>This is a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. A total of 144 eligible patients planning to undergo lung or esophageal surgery will be randomly allocated to the experimental group and the control group. The investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) will be used in each group. The primary endpoint is the success rate of coagulating target blood vessels during surgery. Secondary endpoints include postoperative rebleeding, intraoperative bleeding volume, drainage volume, surgical duration, etc. Postoperative follow-up before and after discharge will be performed.</p><p><strong>Discussion: </strong>This clinical trial aims to evaluate the safety and effectiveness of using the investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and that of the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) to coagulate 5-7 mm blood vessels in thoracic surgery.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov: NCT06002737. The trial was prospectively registered on 16 August 2023, https://www.</p><p><strong>Clinicaltrials: </strong>gov/study/NCT06002737 .</p>","PeriodicalId":49229,"journal":{"name":"BMC Surgery","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11264468/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12893-024-02497-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The ultrasonic scalpel is widely used during surgery. It is safe and effective to close the pulmonary artery branch vessels of 7 mm or below with an ultrasonic energy device as reported. However, there have been no multicenter randomized clinical trial to assess the safety and effectiveness of using ultrasonic scalpel to coagulate 5-7 mm blood vessels in thoracic surgery.

Methods: This is a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. A total of 144 eligible patients planning to undergo lung or esophageal surgery will be randomly allocated to the experimental group and the control group. The investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) will be used in each group. The primary endpoint is the success rate of coagulating target blood vessels during surgery. Secondary endpoints include postoperative rebleeding, intraoperative bleeding volume, drainage volume, surgical duration, etc. Postoperative follow-up before and after discharge will be performed.

Discussion: This clinical trial aims to evaluate the safety and effectiveness of using the investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and that of the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) to coagulate 5-7 mm blood vessels in thoracic surgery.

Trial registration: ClinicalTrials.gov: NCT06002737. The trial was prospectively registered on 16 August 2023, https://www.

Clinicaltrials: gov/study/NCT06002737 .

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用一次性超声波剪凝固 5-7 毫米血管的安全性和有效性:前瞻性、多中心、随机、平行对照、非劣效性临床试验方案。
背景:超声刀在外科手术中被广泛使用。据报道,使用超声波能量装置关闭 7 毫米或以下的肺动脉分支血管是安全有效的。然而,目前还没有多中心随机临床试验来评估在胸外科手术中使用超声刀凝固 5-7 毫米血管的安全性和有效性:这是一项前瞻性、多中心、随机、平行对照、非劣效性临床试验。共有 144 名符合条件的计划接受肺部或食管手术的患者将被随机分配到实验组和对照组。每组都将使用研究产品(Reach Surgical 公司生产的一次性超声波剪)和对照产品(Harmonic Ace + 7,直径 5 毫米高级止血剪)。主要终点是手术中凝固靶血管的成功率。次要终点包括术后再出血、术中出血量、引流量、手术时间等。出院前后将进行术后随访:本临床试验旨在评估在胸外科手术中使用研究产品(Reach Surgical 公司生产的一次性超声波剪)和对照产品(Harmonic Ace + 7,直径 5 毫米高级止血剪)凝固 5-7 毫米血管的安全性和有效性:试验注册:ClinicalTrials.gov:试验注册:ClinicalTrials.gov:NCT06002737。该试验于 2023 年 8 月 16 日进行了前瞻性注册,https://www.Clinicaltrials:gov/study/NCT06002737 。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Surgery
BMC Surgery SURGERY-
CiteScore
2.90
自引率
5.30%
发文量
391
审稿时长
58 days
期刊介绍: BMC Surgery is an open access, peer-reviewed journal that considers articles on surgical research, training, and practice.
期刊最新文献
Real-world study on the application of enhanced recovery after surgery protocol in video-assisted thoracoscopic day surgery for pulmonary nodule resection. The seven-day cumulative post-esophagectomy inflammatory response predicts cancer recurrence. Seprafilm® and adhesive small bowel obstruction in colorectal/abdominal surgery: an updated systematic review. The safety and efficacy of stapler method for transection of the pancreatic parenchyma during pancreatoduodenectomy (STRAP-PD trial): study protocol for a randomized control trial. Challenges and opportunities for Mohs surgery implementation in African healthcare systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1