Klemens Paul Kaiser, Tyll Jandewerth, Julian Bucur, Thomas Kohnen, Christoph Lwowski
{"title":"Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept-source optical coherence tomography-based biometer.","authors":"Klemens Paul Kaiser, Tyll Jandewerth, Julian Bucur, Thomas Kohnen, Christoph Lwowski","doi":"10.1111/ceo.14418","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To assess changes in ocular biometry of the phakic eye after pars-plana-vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.</p><p><strong>Methods: </strong>This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000-centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept-source optical coherence tomography-based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.</p><p><strong>Results: </strong>The mean age was 62.1 ± 8.3 years (range: 37-85). After PPV with SO fill, there was an increase in K<sub>mean</sub> (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to -0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.</p><p><strong>Conclusions: </strong>While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.</p>","PeriodicalId":55253,"journal":{"name":"Clinical and Experimental Ophthalmology","volume":null,"pages":null},"PeriodicalIF":4.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ceo.14418","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: To assess changes in ocular biometry of the phakic eye after pars-plana-vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.
Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000-centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept-source optical coherence tomography-based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.
Results: The mean age was 62.1 ± 8.3 years (range: 37-85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to -0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.
Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.
期刊介绍:
Clinical & Experimental Ophthalmology is the official journal of The Royal Australian and New Zealand College of Ophthalmologists. The journal publishes peer-reviewed original research and reviews dealing with all aspects of clinical practice and research which are international in scope and application. CEO recognises the importance of collaborative research and welcomes papers that have a direct influence on ophthalmic practice but are not unique to ophthalmology.