Umbilical cord blood as a substitute for neonatal blood in measuring serum albumin and immunoglobulin G levels.

IF 2.3 4区 医学 Q2 PATHOLOGY American journal of clinical pathology Pub Date : 2025-01-28 DOI:10.1093/ajcp/aqae089
Toshihiko Ikuta, Sota Iwatani, Seiji Yoshimoto
{"title":"Umbilical cord blood as a substitute for neonatal blood in measuring serum albumin and immunoglobulin G levels.","authors":"Toshihiko Ikuta, Sota Iwatani, Seiji Yoshimoto","doi":"10.1093/ajcp/aqae089","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>In this study, we investigated the clinical feasibility of using umbilical cord blood as an alternative to neonatal blood for measuring serum albumin and immunoglobulin G (IgG) levels in newborns, including preterm newborns.</p><p><strong>Methods: </strong>Serum levels of albumin and IgG were measured in cord and neonatal blood from singleton newborns. We analyzed correlations and systematic errors between cord and neonatal blood measurements, stratifying the results for very preterm newborns (VPNs) born at a gestational age of less than 32 weeks and non-VPNs born at a gestational age of 32 weeks or later.</p><p><strong>Results: </strong>Among all 494 newborns (78 VPNs and 416 non-VPNs), serum albumin and IgG levels were determined for 95.7% and 88.7% of them, respectively. Strong correlations between cord and neonatal blood were observed for the serum albumin and IgG levels (rs = 0.864 and 0.966, respectively). Moreover, the measurement errors between cord and neonatal blood were small for all newborns (0.2 g/dL and 65 mg/dL, respectively). These findings were consistent with both VPNs and non-VPNs.</p><p><strong>Conclusions: </strong>Umbilical cord blood is a suitable substitute for neonatal blood in measuring serum albumin and IgG levels in newborns, even in premature newborns.</p>","PeriodicalId":7506,"journal":{"name":"American journal of clinical pathology","volume":" ","pages":"20-27"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of clinical pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae089","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: In this study, we investigated the clinical feasibility of using umbilical cord blood as an alternative to neonatal blood for measuring serum albumin and immunoglobulin G (IgG) levels in newborns, including preterm newborns.

Methods: Serum levels of albumin and IgG were measured in cord and neonatal blood from singleton newborns. We analyzed correlations and systematic errors between cord and neonatal blood measurements, stratifying the results for very preterm newborns (VPNs) born at a gestational age of less than 32 weeks and non-VPNs born at a gestational age of 32 weeks or later.

Results: Among all 494 newborns (78 VPNs and 416 non-VPNs), serum albumin and IgG levels were determined for 95.7% and 88.7% of them, respectively. Strong correlations between cord and neonatal blood were observed for the serum albumin and IgG levels (rs = 0.864 and 0.966, respectively). Moreover, the measurement errors between cord and neonatal blood were small for all newborns (0.2 g/dL and 65 mg/dL, respectively). These findings were consistent with both VPNs and non-VPNs.

Conclusions: Umbilical cord blood is a suitable substitute for neonatal blood in measuring serum albumin and IgG levels in newborns, even in premature newborns.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用脐带血替代新生儿血液测量血清白蛋白和免疫球蛋白 G 水平。
研究目的本研究探讨了用脐带血替代新生儿血液测量新生儿(包括早产儿)血清白蛋白和免疫球蛋白 G(IgG)水平的临床可行性:方法: 我们测量了单胎新生儿脐带血和新生儿血中的血清白蛋白和 IgG 水平。我们分析了脐带血和新生儿血液测量结果之间的相关性和系统误差,并对胎龄小于 32 周的极早产新生儿(VPN)和胎龄在 32 周或 32 周以上的非早产新生儿进行了分层:在所有 494 名新生儿(78 名 VPN 和 416 名非 VPN)中,分别有 95.7% 和 88.7% 的新生儿检测到血清白蛋白和 IgG 水平。脐带血和新生儿血液中的血清白蛋白和 IgG 水平之间存在很强的相关性(rs = 0.864 和 0.966)。此外,所有新生儿的脐带血和新生儿血的测量误差都很小(分别为 0.2 克/分升和 65 毫克/分升)。这些结果与 VPN 和非 VPN 一致:结论:在测量新生儿血清白蛋白和 IgG 水平时,脐带血是新生儿血液的合适替代品,早产儿也不例外。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.70
自引率
2.90%
发文量
367
审稿时长
3-6 weeks
期刊介绍: The American Journal of Clinical Pathology (AJCP) is the official journal of the American Society for Clinical Pathology and the Academy of Clinical Laboratory Physicians and Scientists. It is a leading international journal for publication of articles concerning novel anatomic pathology and laboratory medicine observations on human disease. AJCP emphasizes articles that focus on the application of evolving technologies for the diagnosis and characterization of diseases and conditions, as well as those that have a direct link toward improving patient care.
期刊最新文献
Continued harmonization of the international normalized ratio across a large laboratory network: Evidence of sustained low interlaboratory variation and bias after a change in instrumentation. Thinking like a pathologist: Morphologic approach to hepatobiliary tumors by ChatGPT. Evaluating pathologist practices in peripheral blood smear review: A comprehensive practice survey. Umbilical cord blood as a substitute for neonatal blood in measuring serum albumin and immunoglobulin G levels. Do errors in requesting and interpreting drug screens harm patients?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1