Real time detection of C reactive protein in interstitial fluid using electrochemical impedance spectroscopy, towards wearable health monitoring

Aristea Grammoustianou, Ali Saeidi, Johan Longo, Felix Risch, Adrian M. Ionescu
{"title":"Real time detection of C reactive protein in interstitial fluid using electrochemical impedance spectroscopy, towards wearable health monitoring","authors":"Aristea Grammoustianou, Ali Saeidi, Johan Longo, Felix Risch, Adrian M. Ionescu","doi":"arxiv-2407.16734","DOIUrl":null,"url":null,"abstract":"Traditional detection methods of C-reactive protein (CRP) inflammation\nbiomarker, in blood are expensive, time-consuming and labor-intensive. Such\nexisting point-of-care CRP detection devices remain invasive, since they need\nblood sampling (finger-pricking or venous puncture). Here, we propose an\nelectrochemical impedance spectroscopy (EIS)-based sensor for the real-time,\nfast, specific, sensitive, and label-free detection of C-reactive protein in\nthe interstitial fluid (ISF) that can be accessed with minimally invasive\nmicroneedle arrays. The sensor has the potential to be integrated in a wearable\ndevice similar with the continuous glucose monitoring, that will detect CRP in\ninterstitial fluid in a non-invasive, inexpensive and straightforward manner.\nThe affinity based assay was tested in both buffer and ISF-like solution. The\nlimit of detection achieved was 0.7 ug/mL of CRP in buffer, and 0.8 ug/mL of\nCRP in ISF-like solution and the sensor shows excellent linearity up to 10\nug/mL. It is worth noting that the proposed sensor operates in low sample\nvolume (down to 5 uL), and has a response time of 100 seconds.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2407.16734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Traditional detection methods of C-reactive protein (CRP) inflammation biomarker, in blood are expensive, time-consuming and labor-intensive. Such existing point-of-care CRP detection devices remain invasive, since they need blood sampling (finger-pricking or venous puncture). Here, we propose an electrochemical impedance spectroscopy (EIS)-based sensor for the real-time, fast, specific, sensitive, and label-free detection of C-reactive protein in the interstitial fluid (ISF) that can be accessed with minimally invasive microneedle arrays. The sensor has the potential to be integrated in a wearable device similar with the continuous glucose monitoring, that will detect CRP in interstitial fluid in a non-invasive, inexpensive and straightforward manner. The affinity based assay was tested in both buffer and ISF-like solution. The limit of detection achieved was 0.7 ug/mL of CRP in buffer, and 0.8 ug/mL of CRP in ISF-like solution and the sensor shows excellent linearity up to 10 ug/mL. It is worth noting that the proposed sensor operates in low sample volume (down to 5 uL), and has a response time of 100 seconds.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用电化学阻抗光谱实时检测组织间液中的 C 反应蛋白,实现可穿戴式健康监测
血液中炎症标志物 C 反应蛋白(CRP)的传统检测方法既昂贵又费时费力。现有的护理点 CRP 检测设备仍然具有侵入性,因为它们需要采血(手指穿刺或静脉穿刺)。在这里,我们提出了一种基于电化学阻抗光谱(EIS)的传感器,用于实时、快速、特异、灵敏和无标记地检测组织间液(ISF)中的 C 反应蛋白。该传感器有望集成到与连续葡萄糖监测类似的穿戴设备中,以非侵入性、廉价和直接的方式检测间质液中的 CRP。在缓冲液和 ISF 样溶液中测试了这种基于亲和力的检测方法。在缓冲液中 CRP 的检测限为 0.7 微克/毫升,在 ISF 样溶液中 CRP 的检测限为 0.8 微克/毫升。值得注意的是,拟议的传感器可在低采样量(低至 5 uL)条件下工作,响应时间为 100 秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental Learning of a Hyperelastic Behavior with a Physics-Augmented Neural Network Modeling water radiolysis with Geant4-DNA: Impact of the temporal structure of the irradiation pulse under oxygen conditions Fast Spot Order Optimization to Increase Dose Rates in Scanned Particle Therapy FLASH Treatments The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy OpenDosimeter: Open Hardware Personal X-ray Dosimeter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1