Evaluation of the Nonlinear Response of KCl Solution to High-Amplitude Stimulation Using a Four-Point Cylindrical Gold Electrode.

IF 2.8 2区 化学 Q3 CHEMISTRY, PHYSICAL The Journal of Physical Chemistry B Pub Date : 2024-08-08 Epub Date: 2024-07-29 DOI:10.1021/acs.jpcb.4c02659
Elham Sharifi, Mehrdad Saviz, Reza Faraji-Dana
{"title":"Evaluation of the Nonlinear Response of KCl Solution to High-Amplitude Stimulation Using a Four-Point Cylindrical Gold Electrode.","authors":"Elham Sharifi, Mehrdad Saviz, Reza Faraji-Dana","doi":"10.1021/acs.jpcb.4c02659","DOIUrl":null,"url":null,"abstract":"<p><p>A four-electrode system and high-voltage amplitude stimulation (with a voltage of more than 1 V) are always used for nonlinear spectroscopy of biological solutions like yeast suspension. Multiple studies indicate that yeast membrane activities are the primary source of the harmonics detected from yeast suspensions. However, other investigations have demonstrated that at least part of the harmonics are mainly due to the nonlinear impedance of the electrode-electrolyte interface. Here, we want to find a mathematical model to analyze the odd harmonics generated by the interface. The KCl solution is the basis of the essential medium used in yeast culture. No study models the nonlinear behavior of the KCl solution using four-electrode. We used a sinusoidal voltage with a low frequency and a high amplitude to test an ionic solution with 1, 30, and 130 mM of potassium chloride. The voltage had no direct current component. Here, we show that the relationship between the amplitude of the excitation voltage and the third harmonic of the current can be accurately represented using the Butler-Volmer equation. Additionally, we analyze the impact of potassium chloride (KCl) concentration on the behavior of the third harmonic. This paper presents a method and model that can be used for nonlinear spectroscopy studies of biological solutions using a four-electrode system with the aim of deriving information from cells without considering the interface effect.</p>","PeriodicalId":60,"journal":{"name":"The Journal of Physical Chemistry B","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Physical Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1021/acs.jpcb.4c02659","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A four-electrode system and high-voltage amplitude stimulation (with a voltage of more than 1 V) are always used for nonlinear spectroscopy of biological solutions like yeast suspension. Multiple studies indicate that yeast membrane activities are the primary source of the harmonics detected from yeast suspensions. However, other investigations have demonstrated that at least part of the harmonics are mainly due to the nonlinear impedance of the electrode-electrolyte interface. Here, we want to find a mathematical model to analyze the odd harmonics generated by the interface. The KCl solution is the basis of the essential medium used in yeast culture. No study models the nonlinear behavior of the KCl solution using four-electrode. We used a sinusoidal voltage with a low frequency and a high amplitude to test an ionic solution with 1, 30, and 130 mM of potassium chloride. The voltage had no direct current component. Here, we show that the relationship between the amplitude of the excitation voltage and the third harmonic of the current can be accurately represented using the Butler-Volmer equation. Additionally, we analyze the impact of potassium chloride (KCl) concentration on the behavior of the third harmonic. This paper presents a method and model that can be used for nonlinear spectroscopy studies of biological solutions using a four-electrode system with the aim of deriving information from cells without considering the interface effect.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用四点圆柱形金电极评估氯化钾溶液对高振幅刺激的非线性响应。
在对酵母悬浮液等生物溶液进行非线性光谱分析时,通常会使用四电极系统和高电压振幅刺激(电压超过 1 V)。多项研究表明,酵母膜活动是从酵母悬浮液中检测到的谐波的主要来源。然而,其他研究表明,至少有一部分谐波主要是由于电极-电解质界面的非线性阻抗造成的。在此,我们希望找到一个数学模型来分析由界面产生的奇次谐波。KCl 溶液是酵母培养所用基本培养基的基础。这项研究利用四电极对 KCl 溶液的非线性行为进行建模。我们使用低频率、高振幅的正弦电压测试了含有 1、30 和 130 毫摩尔氯化钾的离子溶液。该电压没有直流成分。在这里,我们展示了激励电压的振幅与电流三次谐波之间的关系,可以用巴特勒-沃尔默方程来准确表示。此外,我们还分析了氯化钾 (KCl) 浓度对三次谐波行为的影响。本文介绍了一种方法和模型,可用于使用四电极系统对生物溶液进行非线性光谱研究,目的是在不考虑界面效应的情况下从细胞中获取信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
9.10%
发文量
965
审稿时长
1.6 months
期刊介绍: An essential criterion for acceptance of research articles in the journal is that they provide new physical insight. Please refer to the New Physical Insights virtual issue on what constitutes new physical insight. Manuscripts that are essentially reporting data or applications of data are, in general, not suitable for publication in JPC B.
期刊最新文献
Damage Mechanisms in Polyalkenes Irradiated with Ultrashort XUV/X-Ray Laser Pulses. Membrane Stabilization of Helical Previtamin D Conformers as Possible Enhancement of Vitamin D Photoproduction. Molecular Simulations to Investigate the Impact of N6-Methylation in RNA Recognition: Improving Accuracy and Precision of Binding Free Energy Prediction. Issue Publication Information Issue Editorial Masthead
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1