Integrated system for temperature-controlled fast protein liquid chromatography. IV. Continuous ‘one-column’ ‘low-salt’ hydrophobic interaction chromatography

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography A Pub Date : 2024-07-25 DOI:10.1016/j.chroma.2024.465212
{"title":"Integrated system for temperature-controlled fast protein liquid chromatography. IV. Continuous ‘one-column’ ‘low-salt’ hydrophobic interaction chromatography","authors":"","doi":"10.1016/j.chroma.2024.465212","DOIUrl":null,"url":null,"abstract":"<div><p>Systematic development of a temperature-controlled isocratic process for one-column low-salt hydrophobic interaction chromatography (HIC) of proteins employing a travelling cooling zone reactor (TCZR) system, is described. Batch binding and confocal scanning microscopy were employed to define process conditions for temperature-reversible binding of bovine serum albumin (BSA) which were validated in pulse-response temperature switching HIC experiments, before transferring to TCZR-HIC. A thin-walled stainless-steel column mounted with a movable assembly of copper blocks and Peltier elements (travelling cooling zone, TCZ) was used for TCZR-HIC. In pulse-response TCZR-HIC, 12 TCZ movements along the column desorbed 86.3% of the applied BSA monomers in 95.3% purity depleted &gt;6-fold in 2–4 mers and nearly 260-fold in higher molecular weight (HMW) species. For continuous TCZR-HIC, the TCZ was moved 49–58 times during uninterrupted loading of BSA feeds at 0.25, 0.5 or 1 mg·mL<sup>-1</sup>. Each TCZ movement generated a sharp symmetrical elution peak. In the best case, (condition 1: 0.25 mg·mL<sup>-1</sup> BSA; &gt;17 mg BSA applied per mL of bed) the height of TCZ elution peaks approached pseudo-steady midway through the loading phase with no rise in baseline UV280 signal between peaks. Peak composition remained constant averaging 94.4% monomer, 5.6% 2–4 mers and &lt;0.05% HMW. Monomers were recovered in quantitative yield depleted &gt;3.1 fold in 2–4 mers and 92-fold in HMW species cf. the feed (63.6% monomers, 21.8% 2–4 mers, 14.6% HMW). However, increasing the BSA concentration to 1 mg·mL<sup>-1</sup> (condition 2) or employing a fouled HIC column with 0.5 mg·mL<sup>-1</sup> BSA (condition 3) compromised monomer purification performance.</p></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967324005867","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Systematic development of a temperature-controlled isocratic process for one-column low-salt hydrophobic interaction chromatography (HIC) of proteins employing a travelling cooling zone reactor (TCZR) system, is described. Batch binding and confocal scanning microscopy were employed to define process conditions for temperature-reversible binding of bovine serum albumin (BSA) which were validated in pulse-response temperature switching HIC experiments, before transferring to TCZR-HIC. A thin-walled stainless-steel column mounted with a movable assembly of copper blocks and Peltier elements (travelling cooling zone, TCZ) was used for TCZR-HIC. In pulse-response TCZR-HIC, 12 TCZ movements along the column desorbed 86.3% of the applied BSA monomers in 95.3% purity depleted >6-fold in 2–4 mers and nearly 260-fold in higher molecular weight (HMW) species. For continuous TCZR-HIC, the TCZ was moved 49–58 times during uninterrupted loading of BSA feeds at 0.25, 0.5 or 1 mg·mL-1. Each TCZ movement generated a sharp symmetrical elution peak. In the best case, (condition 1: 0.25 mg·mL-1 BSA; >17 mg BSA applied per mL of bed) the height of TCZ elution peaks approached pseudo-steady midway through the loading phase with no rise in baseline UV280 signal between peaks. Peak composition remained constant averaging 94.4% monomer, 5.6% 2–4 mers and <0.05% HMW. Monomers were recovered in quantitative yield depleted >3.1 fold in 2–4 mers and 92-fold in HMW species cf. the feed (63.6% monomers, 21.8% 2–4 mers, 14.6% HMW). However, increasing the BSA concentration to 1 mg·mL-1 (condition 2) or employing a fouled HIC column with 0.5 mg·mL-1 BSA (condition 3) compromised monomer purification performance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
温控快速蛋白质液相色谱综合系统。IV.连续'单柱''低盐'疏水相互作用色谱。
本文介绍了采用流动冷却区反应器(TCZR)系统对单柱低盐蛋白质疏水相互作用色谱(HIC)的温控等度工艺进行系统开发的情况。利用批量结合和共聚焦扫描显微镜确定了牛血清白蛋白(BSA)温度可逆结合的工艺条件,并在转移到 TCZR-HIC 之前在脉冲响应温度切换 HIC 实验中进行了验证。TCZR-HIC 使用的是一个薄壁不锈钢柱,柱上安装有铜块和珀尔帖元件的可移动组件(移动冷却区,TCZ)。在脉冲响应 TCZR-HIC 中,沿着色谱柱移动 12 次 TCZ,可解吸 86.3% 的应用 BSA 单体,纯度为 95.3%,其中 2-4 mers 的解吸量大于 6 倍,高分子量 (HMW) 种类的解吸量接近 260 倍。对于连续 TCZR-HIC,在不间断加载 0.25、0.5 或 1 mg-mL-1 的 BSA 进料期间,TCZ 移动 49-58 次。每次 TCZ 移动都会产生一个尖锐的对称洗脱峰。在最好的情况下(条件 1:0.25 毫克-毫升-1 BSA;每毫升床面施加 >17 毫克 BSA),TCZ 洗脱峰的高度在加载阶段的中途接近假稳定,峰间的基线 UV280 信号没有上升。与进样(63.6% 单体、21.8% 2-4 mers、14.6% HMW)相比,峰组成保持不变,平均为 94.4% 单体、5.6% 2-4 mers、3.1 倍 2-4 mers 和 92 倍 HMW。然而,将 BSA 浓度提高到 1 mg-mL-1(条件 2)或使用含 0.5 mg-mL-1 BSA 的堵塞 HIC 色谱柱(条件 3)会影响单体纯化性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Chromatography A
Journal of Chromatography A 化学-分析化学
CiteScore
7.90
自引率
14.60%
发文量
742
审稿时长
45 days
期刊介绍: The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.
期刊最新文献
Fabrication of a green double-layered hybrid nanocomposite via electrospinning of polyethersulphone/natural deep eutectic solvent on bacterial cellulose for determination of multiclass pesticides in water samples Accurate measurement of Soret coefficients in binary hydrocarbons mixtures based on composite methods Spherical cellulose/chitosan aerogel–supported MOF-199 for the magnetic solid-phase extraction of benzodiazepines from urine Hydrophilic interaction liquid chromatography: An efficient tool for assessing thorium interaction with phosphorylated biomimetic peptides Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1