Efficacy and safety of a novel monopolar radiofrequency device with a continuous water-cooling system in patients with age-related facial volume loss.

Seungwon Lee, Jihyun Hyun, Yeonwoo Shin, Boncheol Leo Goo
{"title":"Efficacy and safety of a novel monopolar radiofrequency device with a continuous water-cooling system in patients with age-related facial volume loss.","authors":"Seungwon Lee, Jihyun Hyun, Yeonwoo Shin, Boncheol Leo Goo","doi":"10.1080/09546634.2024.2333028","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Esthetic radiofrequency (RF) technology has much attracted public attention with the increasing demand for skin rejuvenation. A continuous water cooling-based monopolar RF (MRF) device was designed for the first time to protect the epidermis and maximize clinical outcomes.</p><p><strong>Objective: </strong>Assess the efficacy and safety of the proposed MRF device in patients with mild-to-moderate sunken cheeks and jawline laxity.</p><p><strong>Methods: </strong>Twenty-one patients underwent a single session of MRF treatment. Quantitative analysis was performed using a 3D imaging technique. Postprocedural clinical improvements were assessed with the Merz Scale. Regarding safety, adverse events (AEs), thermal sensation (TS) and pain intensity were explored. Patient satisfaction was surveyed with the Self-Assessment Questionnaire (SAQ).</p><p><strong>Results: </strong>The follow-up investigation demonstrated that facial volume increased across the cheek and jawline, with lifting effects throughout the treatment area. The Merz Scale assessment revealed that sunken cheeks, sagging jawlines and wrinkles were markedly improved. In addition, there were transient AEs, mild TS and moderate pain. In SAQ, 81% patients were satisfied with the procedure.</p><p><strong>Conclusions: </strong>This study provided quantitative evidence for postprocedural volumetric increases along with enhanced lifting effects, strongly implying that the proposed MRF device can be an attractive option for improving facial skin volume loss and laxity.</p>","PeriodicalId":94235,"journal":{"name":"The Journal of dermatological treatment","volume":"35 1","pages":"2333028"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of dermatological treatment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/09546634.2024.2333028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Esthetic radiofrequency (RF) technology has much attracted public attention with the increasing demand for skin rejuvenation. A continuous water cooling-based monopolar RF (MRF) device was designed for the first time to protect the epidermis and maximize clinical outcomes.

Objective: Assess the efficacy and safety of the proposed MRF device in patients with mild-to-moderate sunken cheeks and jawline laxity.

Methods: Twenty-one patients underwent a single session of MRF treatment. Quantitative analysis was performed using a 3D imaging technique. Postprocedural clinical improvements were assessed with the Merz Scale. Regarding safety, adverse events (AEs), thermal sensation (TS) and pain intensity were explored. Patient satisfaction was surveyed with the Self-Assessment Questionnaire (SAQ).

Results: The follow-up investigation demonstrated that facial volume increased across the cheek and jawline, with lifting effects throughout the treatment area. The Merz Scale assessment revealed that sunken cheeks, sagging jawlines and wrinkles were markedly improved. In addition, there were transient AEs, mild TS and moderate pain. In SAQ, 81% patients were satisfied with the procedure.

Conclusions: This study provided quantitative evidence for postprocedural volumetric increases along with enhanced lifting effects, strongly implying that the proposed MRF device can be an attractive option for improving facial skin volume loss and laxity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带持续水冷系统的新型单极射频设备对老年性面部容积损失患者的疗效和安全性。
背景:随着嫩肤需求的增加,射频美容技术备受公众关注。我们首次设计了一种基于持续水冷却的单极射频(MRF)设备,以保护表皮并最大限度地提高临床效果:方法:21 名患者接受了一次单极射频治疗:方法:21 名患者接受了一次 MRF 治疗。采用三维成像技术进行定量分析。采用默茨量表评估治疗后的临床改善情况。在安全性方面,探讨了不良事件(AEs)、热感觉(TS)和疼痛强度。通过自我评估问卷(SAQ)调查了患者的满意度:随访调查显示,脸颊和下颌线的面部体积有所增加,整个治疗区域都有提升效果。默茨量表评估显示,脸颊凹陷、下颌角下垂和皱纹明显改善。此外,还出现了短暂的 AEs、轻度 TS 和中度疼痛。在SAQ中,81%的患者对手术表示满意:这项研究提供了术后容积增加和提拉效果增强的定量证据,有力地证明了所建议的 MRF 设备是改善面部皮肤容积损失和松弛的一种有吸引力的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficacy and safety of sofpironium in treatment of primary hyperhidrosis: a systematic review. Efficacy and safety of 308-nm Excimer lamp combined with Tacrolimus 0.1% ointment vs Tacrolimus 0.1% ointment as monotherapy in treating children with limited vitiligo: a randomized controlled trial. The wide variety of methotrexate dosing regimens for the treatment of atopic dermatitis: a systematic review. Comparing Mohs micrographic surgery and wide local excision in the management of head and neck dermatofibrosarcoma protuberans: a scoping review. The primary role of sebum in the pathophysiology of acne vulgaris and its therapeutic relevance in acne management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1