Comparison of diagnostic performance of transesophageal echocardiography and positron emission tomography in patients with cardiovascular implantable electronic device infections.

IF 3.8 3区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Kardiologia polska Pub Date : 2024-01-01 Epub Date: 2024-07-30 DOI:10.33963/v.phj.101702
Nazli Turan Serifler, Turkan Seda Tan Kurklu, Irem Muge Akbulut Koyuncu, Ayse Irem Demirtola, Sibel Turhan
{"title":"Comparison of diagnostic performance of transesophageal echocardiography and positron emission tomography in patients with cardiovascular implantable electronic device infections.","authors":"Nazli Turan Serifler, Turkan Seda Tan Kurklu, Irem Muge Akbulut Koyuncu, Ayse Irem Demirtola, Sibel Turhan","doi":"10.33963/v.phj.101702","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The modified Duke criteria and transesophageal echocardiography (TEE) are often insufficient to diagnose infective endocarditis in patients with cardiovascular implantable electronic devices (CIEDs). F-18-fluoro-2-deoxy-glucose positron emission tomography (18F-FDG PET/CT) is a promising method for detecting lead endocarditis.</p><p><strong>Aims: </strong>The study aimed to compare diagnostic performance of 18F-FDG PET/CT and TEE in detecting lead endocarditis (LE).</p><p><strong>Methods: </strong>We included 40 patients admitted to the hospital for CIED infection. Patients were classified as \"LE-positive\" and \"LE-negative\" according to TEE and 18F-FDG PET/CT findings. After three months of follow-up, the patients' lead cultures, tissue and blood cultures, and clinical responses after antibiotic treatment were reviewed using the Duke criteria. The final exact diagnosis was compared with 18F-FDG PET/CT and TEE findings.</p><p><strong>Results: </strong>No involvement was observed on 18F-FDG PET/CT in 12 patients (30%). The remaining 25% of patients had device pocket involvement, and two patients had systemic involvement. In the follow-up of 23 patients diagnosed with LE by TEE, 14 were consistent with LE. Seventeen of 18 patients with suspicion of LE were diagnosed with definite LE by 18F-FDG PET/CT. Six of the 22 patients with negative 18F-FDG PET/CT scans were false negative and diagnosed as definite infective endocarditis. 18F-FDG PET/CT had sensitivity of 73.9% and specificity of 94.1%. It was observed that there was a statistically significant difference between TEE and PET (P = 0.006).</p><p><strong>Conclusion: </strong>18F-FDG PET/CT is superior to TEE in diagnosing IE in patients with CIED.</p>","PeriodicalId":17784,"journal":{"name":"Kardiologia polska","volume":" ","pages":"958-966"},"PeriodicalIF":3.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kardiologia polska","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.33963/v.phj.101702","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The modified Duke criteria and transesophageal echocardiography (TEE) are often insufficient to diagnose infective endocarditis in patients with cardiovascular implantable electronic devices (CIEDs). F-18-fluoro-2-deoxy-glucose positron emission tomography (18F-FDG PET/CT) is a promising method for detecting lead endocarditis.

Aims: The study aimed to compare diagnostic performance of 18F-FDG PET/CT and TEE in detecting lead endocarditis (LE).

Methods: We included 40 patients admitted to the hospital for CIED infection. Patients were classified as "LE-positive" and "LE-negative" according to TEE and 18F-FDG PET/CT findings. After three months of follow-up, the patients' lead cultures, tissue and blood cultures, and clinical responses after antibiotic treatment were reviewed using the Duke criteria. The final exact diagnosis was compared with 18F-FDG PET/CT and TEE findings.

Results: No involvement was observed on 18F-FDG PET/CT in 12 patients (30%). The remaining 25% of patients had device pocket involvement, and two patients had systemic involvement. In the follow-up of 23 patients diagnosed with LE by TEE, 14 were consistent with LE. Seventeen of 18 patients with suspicion of LE were diagnosed with definite LE by 18F-FDG PET/CT. Six of the 22 patients with negative 18F-FDG PET/CT scans were false negative and diagnosed as definite infective endocarditis. 18F-FDG PET/CT had sensitivity of 73.9% and specificity of 94.1%. It was observed that there was a statistically significant difference between TEE and PET (P = 0.006).

Conclusion: 18F-FDG PET/CT is superior to TEE in diagnosing IE in patients with CIED.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经食道超声心动图和正电子发射断层扫描在心血管植入式电子设备感染患者中的诊断效果比较。
背景:改良的Duke标准和经食管超声心动图(TEE)往往不足以诊断心血管植入式电子装置(cied)患者的感染性心内膜炎。f -18-氟-2-脱氧葡萄糖正电子发射断层扫描(18F-FDG PET/CT)是一种很有前途的检测铅性心内膜炎的方法。目的:比较18F-FDG PET/CT与TEE对铅性心内膜炎(LE)的诊断价值。方法:选取40例因CIED感染住院的患者。根据TEE和18F-FDG PET/CT结果将患者分为“le阳性”和“le阴性”。经过三个月的随访,患者的铅培养,组织和血液培养,以及抗生素治疗后的临床反应使用杜克标准进行审查。最终的准确诊断与18F-FDG PET/CT和TEE结果进行比较。结果:12例(30%)患者18F-FDG PET/CT未见受累。其余25%的患者有器械袋受累,2例患者有全身受累。在23例经TEE诊断为LE的患者随访中,14例符合LE。18例疑似LE患者中,17例经18F-FDG PET/CT诊断为明确LE。22例18F-FDG PET/CT阴性患者中有6例为假阴性,确诊为感染性心内膜炎。18F-FDG PET/CT敏感性73.9%,特异性94.1%。TEE与PET比较,差异有统计学意义(P = 0.006)。结论:18F-FDG PET/CT对CIED患者IE的诊断优于TEE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Kardiologia polska
Kardiologia polska 医学-心血管系统
CiteScore
3.00
自引率
24.20%
发文量
431
审稿时长
3-6 weeks
期刊介绍: Kardiologia Polska (Kardiol Pol, Polish Heart Journal) is the official peer-reviewed journal of the Polish Cardiac Society (PTK, Polskie Towarzystwo Kardiologiczne) published monthly since 1957. It aims to provide a platform for sharing knowledge in cardiology, from basic science to translational and clinical research on cardiovascular diseases.
期刊最新文献
A standardized transesophageal echocardiography approach to assess left atrial appendage occlusion after robotic cardiac surgery. Left atrial strain in children treated with anthracyclines for acute lymphoblastic leukemia - preliminary observation of the early subclinical diastolic left ventricle impairment. Cryptogenic stroke caused by thrombus in a left-sided atrial septal pouch in an otherwise healthy woman. Simplified transcatheter aortic valve implantation. An expert consensus of the Association of CardioVascular Interventions of Polish Cardiac Society. Impella-induced torrential aortic regurgitation after balloon aortic valvuloplasty requiring bailout TAVI.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1